Real-time Photonic Measurements, Data Management, and Processing

A versatile single-photon spectrograph for the spectral measurement of the two-photon state

Xiao Xiang, Ruifang Dong, Runai Quan, Yaqing Jin, Ye Yang, Ming Li

Published Oct 9, 2020• 0 citations
Publisher

Abstract

A new type of single-photon spectrograph combining a tunable optical filter and a dispersive element is presented for measurement of the spectral properties of the two-photon state. In comparison with the previous single-photon spectrograph which is merely based on the dispersive Fourier transformation (DFT) technique, this scheme avoids the need for additional wavelength calibration and the electronic laser trigger for coincidence measurement; therefore, its application is extended to continuous wave (CW) pumped two-photon sources. The achievable precision of the spectrum measurement has also been discussed in theory and demonstrated experimentally with a CW pumped periodically poled lithium niobate (PPLN) waveguide-based spontaneous parametric down conversion photon source. Such a device is expected to be a versatile tool for the characterization of the frequency entangled two-photon state.

DOI
10.1117/12.2574997

Related papers

Hybrid frequency-time spectrograph for the spectral measurement of the two-photon state

Xiao Xiang, Ruifang Dong, Runai Quan +5 more

In this Letter, a hybrid frequency-time spectrograph combining a tunable optical filter and a dispersive element is presented for measurement of the spectral properties of the two-photon state. In comparison with the previous single-photon spectrograph utilizing the dispersive Fourier transformation (DFT) technique, this method is advanced since it avoids the need for additional wavelength calibration and the electronic laser trigger for coincidence measurement; therefore, its application is extended to continuous wave (CW) pumped two-photon sources. The achievable precision of the spectrum measurement has also been discussed in theory and demonstrated experimentally with a CW pumped periodically poled lithium niobate (PPLN) waveguide-based spontaneous parametric down-conversion photon source. Such a device is expected to be a versatile tool for the characterization of the frequency entangled two-photon state.

Optics Letters•Apr 27, 2020•17 citations

Fibre assisted single photon spectrograph

Malte Avenhaus, A. Eckstein, Peter J. Mosley +1 more

An experimental detection scheme is demonstrated for directly measuring the spectrum of a parametric down-conversion (PDC) source by the use of a highly dispersive fibre. A temporally narrow pulse envelope is spectrally stretched in time by chromatic group velocity dispersion. In order to maximise this effect the high group velocity dispersion of a commercially available dispersion compensating fibre is employed. If the pulse contains only a single photon on average, detection with a conventional APD yields precise information about the arrival time of the photon at the end of the fiber. When carefully calibrated one can accurately reconstruct the original spectral distribution from the measured temporal distribution. Harnessing a single mode fiber for this type of spectrometer brings the benefits of low loss due to efficient guidance, simplicity of alignment and the necessity of only a single detector to scan the spectrum. A fibre assisted single photon spectrograph is employed to measure the correlation spectrum of a bi-photonic state. State generation is achieved by a type-II parametric downconversion process at 1550 nm in a KTP waveguide structure.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2009•0 citations

Measurement of the spectral properties of the coincident-frequency entangled biphoton state at optical communication wavelength

Wang Meng-Meng, Quan Run-Ai, Tai Zhao-Yang +4 more

The frequency entangled biphoton source generated via spontaneous parametric down-conversion (SPDC) process has found important applications in the fields of quantum clock synchronization, quantum communication, quantum information processing, etc. As quantum technologies evolve, quantitative characterization of the frequency entanglement becomes necessary and has been implemented by measuring the spectral properties of the biphoton state. However, due to the high dark rate and low quantum efficiency of the InGaAs single-photon detectors, direct measurement of the spectral properties of the biphoton state at optical communication wavelength is hard to implement. In this paper, we report the measurement of the spectral properties of a biphoton state at optical communication wavelength which is generated from periodically poled potassium titanyl phosphate (PPKTP) pumped by an ultra-short pulsed optical source at 787 nm. Based on the coincidence measurement setup together with two infrared spectrometers, the spectra of the signal and idler photons are obtained with their center wavelengths being 1574.4 nm and 1574.9 nm, while their 3-dB bandwidths being 35.3 nm and 37.6 nm respectively. The joint spectrum of the photon pair is observed as well and shows a coincident-frequency entanglement and a joint spectrum bandwidth of 3 nm. According to the ratio of the single-photon spectral bandwidth to the joint spectral bandwidth of the photon pairs, the degree of frequency entanglement is quantified to be 12, denoting a relatively high quality of the entanglement.

Acta Physica Sinica•Jan 1, 2014•4 citations

Detection and spectral measurement of single photons in communication bands using up-conversion technology

Long Ma, Oliver Slattery, Xiao Hong Tang

Quantum information systems are commonly operated in conventional communication bands (1310 and 1550 nm) over an optical fiber to take advantage of low transmission loss. However, the detection and spectral measurement of single photons in these communication bands are limited due to high noise and low sensitivity of single photon detectors in the wavelength ranges. To demonstrate high efficiency detection and high sensitivity spectral measurement, we have implemented a single photon detector and a spectrometer based on frequency up-conversion technology. This detector and spectrometer uses a 5-cm periodically poled lithium niobate (PPLN) waveguide and a tunable pump laser around 1550 nm, to convert signal photons around 1310 to 710 nm. The converted photons are then detected by a silicon-based avalanche photodiode (APD). The overall detection efficiency of the single photon detector is as high as 32%, which is three times higher than commercial InGaAs APDs. The sensitivity of the spectrometer is measured to be −126 dBm, which is at least three orders-of-magnitude better than any commercial optical spectrum analyzer in this wavelength range.

Laser Physics•Apr 2, 2010•11 citations

Tunable diode laser based biphoton source for quantum spectroscopy

Andreas Jechow, Axel Heuer, Ralf Menzel

Photon pairs generated by spontaneous parametric down-conversion (SPDC) are essential for a number of quantum-optics experiments. By utilizing periodically poled (PP) waveguide structures high flux rates of biphotons in one transversal mode can be obtained. The biphoton source presented here is explicitly designed for quantum spectroscopic application and is based on a frequency doubled broad area external cavity diode laser (BA-ECDL) that pumps SPDC inside a PPLN waveguide crystal. A time correlated single photon counting device has been used for the correlation measurements.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2009•0 citations

Spectral characterization of photon-pair sources via classical sum-frequency generation

Fumihiro Kaneda, Jo Oikawa, Masahiro Yabuno +5 more

Tailoring spectral properties of photon pairs is of great importance for optical quantum information and measurement applications. High-resolution spectral measurement is a key technique for engineering spectral properties of photons, making them ideal for various quantum applications. Here we demonstrate spectral measurements and optimization of frequency-entangled photon pairs produced via spontaneous parametric downconversion (SPDC), utilizing frequency-resolved sum-frequency generation (SFG), the reverse process of SPDC. A joint phase-matching spectrum of a nonlinear crystal around 1580 nm is captured with a 40 pm resolution and a > 40 dB signal-to-noise ratio, which is significantly improved compared to traditional frequency-resolved coincidence measurements. Moreover, our scheme is applicable to collinear degenerate sources whose characterization is difficult with previously demonstrated stimulated difference frequency generation (DFG). We also illustrate that the observed phase-matching function is useful for finding an optimal pump spectrum to maximize the spectral indistinguishability of SPDC photons. We expect that our precise spectral characterization technique will be useful tool for characterizing and tailoring SPDC sources for a wide range of optical quantum applications.

arXiv:2010.07678•Optics Express•Nov 30, 2020•15 citations
A new type of single-photon spectrograph combining a tunable optical filter and a dispersive element is presented for measurement of the spectral properties of the two-photon state. In comparison with the previous single-photon spectrograph which is merely based on the dispersive Fourier transformation (DFT) technique, this scheme avoids the need for additional wavelength calibration and the electronic laser trigger for coincidence measurement; therefore, its application is extended to continuous wave (CW) pumped two-photon sources. The achievable precision of the spectrum measurement has also been discussed in theory and demonstrated experimentally with a CW pumped periodically poled lithium niobate (PPLN) waveguide-based spontaneous parametric down conversion photon source. Such a device is expected to be a versatile tool for the characterization of the frequency entangled two-photon state.
In this Letter, a hybrid frequency-time spectrograph combining a tunable optical filter and a dispersive element is presented for measurement of the spectral properties of the two-photon state. In comparison with the previous single-photon spectrograph utilizing the dispersive Fourier transformation (DFT) technique, this method is advanced since it avoids the need for additional wavelength calibration and the electronic laser trigger for coincidence measurement; therefore, its application is extended to continuous wave (CW) pumped two-photon sources. The achievable precision of the spectrum measurement has also been discussed in theory and demonstrated experimentally with a CW pumped periodically poled lithium niobate (PPLN) waveguide-based spontaneous parametric down-conversion photon source. Such a device is expected to be a versatile tool for the characterization of the frequency entangled two-photon state.
An experimental detection scheme is demonstrated for directly measuring the spectrum of a parametric down-conversion (PDC) source by the use of a highly dispersive fibre. A temporally narrow pulse envelope is spectrally stretched in time by chromatic group velocity dispersion. In order to maximise this effect the high group velocity dispersion of a commercially available dispersion compensating fibre is employed. If the pulse contains only a single photon on average, detection with a conventional APD yields precise information about the arrival time of the photon at the end of the fiber. When carefully calibrated one can accurately reconstruct the original spectral distribution from the measured temporal distribution. Harnessing a single mode fiber for this type of spectrometer brings the benefits of low loss due to efficient guidance, simplicity of alignment and the necessity of only a single detector to scan the spectrum. A fibre assisted single photon spectrograph is employed to measure the correlation spectrum of a bi-photonic state. State generation is achieved by a type-II parametric downconversion process at 1550 nm in a KTP waveguide structure.
The frequency entangled biphoton source generated via spontaneous parametric down-conversion (SPDC) process has found important applications in the fields of quantum clock synchronization, quantum communication, quantum information processing, etc. As quantum technologies evolve, quantitative characterization of the frequency entanglement becomes necessary and has been implemented by measuring the spectral properties of the biphoton state. However, due to the high dark rate and low quantum efficiency of the InGaAs single-photon detectors, direct measurement of the spectral properties of the biphoton state at optical communication wavelength is hard to implement. In this paper, we report the measurement of the spectral properties of a biphoton state at optical communication wavelength which is generated from periodically poled potassium titanyl phosphate (PPKTP) pumped by an ultra-short pulsed optical source at 787 nm. Based on the coincidence measurement setup together with two infrared spectrometers, the spectra of the signal and idler photons are obtained with their center wavelengths being 1574.4 nm and 1574.9 nm, while their 3-dB bandwidths being 35.3 nm and 37.6 nm respectively. The joint spectrum of the photon pair is observed as well and shows a coincident-frequency entanglement and a joint spectrum bandwidth of 3 nm. According to the ratio of the single-photon spectral bandwidth to the joint spectral bandwidth of the photon pairs, the degree of frequency entanglement is quantified to be 12, denoting a relatively high quality of the entanglement.
Quantum information systems are commonly operated in conventional communication bands (1310 and 1550 nm) over an optical fiber to take advantage of low transmission loss. However, the detection and spectral measurement of single photons in these communication bands are limited due to high noise and low sensitivity of single photon detectors in the wavelength ranges. To demonstrate high efficiency detection and high sensitivity spectral measurement, we have implemented a single photon detector and a spectrometer based on frequency up-conversion technology. This detector and spectrometer uses a 5-cm periodically poled lithium niobate (PPLN) waveguide and a tunable pump laser around 1550 nm, to convert signal photons around 1310 to 710 nm. The converted photons are then detected by a silicon-based avalanche photodiode (APD). The overall detection efficiency of the single photon detector is as high as 32%, which is three times higher than commercial InGaAs APDs. The sensitivity of the spectrometer is measured to be −126 dBm, which is at least three orders-of-magnitude better than any commercial optical spectrum analyzer in this wavelength range.
Photon pairs generated by spontaneous parametric down-conversion (SPDC) are essential for a number of quantum-optics experiments. By utilizing periodically poled (PP) waveguide structures high flux rates of biphotons in one transversal mode can be obtained. The biphoton source presented here is explicitly designed for quantum spectroscopic application and is based on a frequency doubled broad area external cavity diode laser (BA-ECDL) that pumps SPDC inside a PPLN waveguide crystal. A time correlated single photon counting device has been used for the correlation measurements.
Tailoring spectral properties of photon pairs is of great importance for optical quantum information and measurement applications. High-resolution spectral measurement is a key technique for engineering spectral properties of photons, making them ideal for various quantum applications. Here we demonstrate spectral measurements and optimization of frequency-entangled photon pairs produced via spontaneous parametric downconversion (SPDC), utilizing frequency-resolved sum-frequency generation (SFG), the reverse process of SPDC. A joint phase-matching spectrum of a nonlinear crystal around 1580 nm is captured with a 40 pm resolution and a > 40 dB signal-to-noise ratio, which is significantly improved compared to traditional frequency-resolved coincidence measurements. Moreover, our scheme is applicable to collinear degenerate sources whose characterization is difficult with previously demonstrated stimulated difference frequency generation (DFG). We also illustrate that the observed phase-matching function is useful for finding an optimal pump spectrum to maximize the spectral indistinguishability of SPDC photons. We expect that our precise spectral characterization technique will be useful tool for characterizing and tailoring SPDC sources for a wide range of optical quantum applications.