Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Separation in a nonuniform magnetic field of the isotopes of atoms interacting with an intense resonant light wave

G. V. Skrotskiǐ, G. I. Solomakho

Published Apr 1, 1980• 0 citations
OpenAlex

Abstract

The process of optical orientation of atomic isotopes in the field of a strong resonant light wave and an inhomogeneous magnetic field is analyzed and the conditions for reliable isotope separation are determined.

Related papers

Magnetic resonance of optically oriented atoms in nonuniform fields

L. N. Novikov, S. L. Votyakov, V. P. Suetin

Radiophysics and Quantum Electronics•Dec 1, 1976•0 citations

About the Zeeman Light-Induced Frequency Shift of the Radio-Optical Resonance in Optically Oriented Isotopes of Alkali Metals

A. A. Podvyaznyi, A. A. Sakantsev, V. V. Semenov

Russian Physics Journal•Sep 1, 2003•2 citations

Collinear Three-Photon Excitation of a Strongly Forbidden Optical Clock Transition

Samuel P. Carman, Jan Rudolph, Benjamin E. Garber +7 more

The S 1 0 − P 3 0 clock transition in strontium serves as the foundation for the world’s best atomic clocks and for gravitational wave detector concepts in clock atom interferometry. This transition is weakly allowed in the fermionic isotope Sr 87 but strongly forbidden in bosonic isotopes. Here, we demonstrate coherent excitation of the clock transition in bosonic Sr 88 using a novel collinear three-photon process in a weak magnetic field. We observe Rabi oscillations with frequencies of up to 50 kHz using W / cm 2 laser intensities and Gauss-level magnetic field amplitudes. The absence of nuclear spin in bosonic isotopes offers decreased sensitivity to magnetic fields and optical lattice light shifts, enabling atomic clocks with reduced systematic errors. The collinear propagation of the laser fields permits the interrogation of spatially separated atomic ensembles with common laser pulses, a key requirement for dark matter searches and gravitational wave detection with next-generation quantum sensors.

arXiv:2406.07902•Physical Review X•Jun 2, 2025•12 citations

Optical magnetic resonances induced by the interference of reactive components in the near radiation-field zone of atoms in a glow discharge of a mixture of even neon isotopes

Э. Г. Сапрыкин

Four types of anomalous optical magnetic resonances shifted with respect to the zero magnetic field and with different shapes are found in radiation of a glow discharge in a mixture of even neon isotopes placed in a swept longitudinal magnetic field. This testifies to the manifestation of collective processes of synchronous light emission by oscillators belonging to isotopically different spatially separated atoms in discharge plasma. The origin of resonances is associated with nonstationary interference of reactive fields in the near radiation-field zones of emission of atoms, averaged over the lifetime of the fields (interference), while different types of resonances are associated with different methods of synchronization of the phases of the fields.

Journal of Experimental and Theoretical Physics•Feb 1, 2016•3 citations

Rotation of the polarization ellipse on quasilinear interaction of light with the ground state of atoms in the 1/2 --> 1/2 transition under conditions of optical self-pumping in a magnetic field

N. L. Kosulin, Vladimir S. Smirnov, Anatolii M Tumaikin

OptSp•Apr 1, 1986•0 citations

Orientational Light Shift Experimental Estimate of 0-0 Resonance Frequency in Rubidium Vapor

Ермак Сергей Викторович, Roman Lozov, V. V. Semenov

The paper presents the measurements results of the orientational light shift of the radio-optical 0-0 resonance frequency in the rubidium vapor with isotopic pumping. The experiments were done on a laboratory quantum discriminator, the functional diagram of which contained a known element set for rubidium frequency standard on a gas cell. The discriminator was placed in the three identical pairs of Helmholtz coils, 50 cm in diameter, which created a working magnetic field (10 μT, 3 μT, and 1 μT) in the area of the gas cell. Helmholtz coils were connected to alternating voltage sources to create a rotating magnetic field relative to the normal to the direction of the pumping light. To weaken external magnetic noise and inhomogeneities of the laboratory magnetic field, the entire system was placed in a magnetic shield with a screening factor of ~ 103, which practically made it possible to exclude the effect of the residual field on the measurements accuracy. The main experimental results are formulated as follows: the orientational frequency shift of the 0-0 radio-optical resonance does not depend on the magnitude of the working magnetic field and is linearly related to the pumping light intensity; when the working magnetic field is oriented normal to the quantum discriminator optical axis, the tensor and scalar components of the light shift have equal (positive) signs, which at any temperature of the filter-cell leads to their impossible compensation; when the working magnetic field is oriented along the quantum discriminator optical axis, the tensor and scalar components of the light shift have opposite signs, which at the corresponding temperature of the filter-cell leads to their possible (partial) compensation.

International Conference on Electrical Engineering and Photonics (EExPolytech)•Oct 15, 2020•4 citations
The S 1 0 − P 3 0 clock transition in strontium serves as the foundation for the world’s best atomic clocks and for gravitational wave detector concepts in clock atom interferometry. This transition is weakly allowed in the fermionic isotope Sr 87 but strongly forbidden in bosonic isotopes. Here, we demonstrate coherent excitation of the clock transition in bosonic Sr 88 using a novel collinear three-photon process in a weak magnetic field. We observe Rabi oscillations with frequencies of up to 50 kHz using W / cm 2 laser intensities and Gauss-level magnetic field amplitudes. The absence of nuclear spin in bosonic isotopes offers decreased sensitivity to magnetic fields and optical lattice light shifts, enabling atomic clocks with reduced systematic errors. The collinear propagation of the laser fields permits the interrogation of spatially separated atomic ensembles with common laser pulses, a key requirement for dark matter searches and gravitational wave detection with next-generation quantum sensors.
Four types of anomalous optical magnetic resonances shifted with respect to the zero magnetic field and with different shapes are found in radiation of a glow discharge in a mixture of even neon isotopes placed in a swept longitudinal magnetic field. This testifies to the manifestation of collective processes of synchronous light emission by oscillators belonging to isotopically different spatially separated atoms in discharge plasma. The origin of resonances is associated with nonstationary interference of reactive fields in the near radiation-field zones of emission of atoms, averaged over the lifetime of the fields (interference), while different types of resonances are associated with different methods of synchronization of the phases of the fields.
The paper presents the measurements results of the orientational light shift of the radio-optical 0-0 resonance frequency in the rubidium vapor with isotopic pumping. The experiments were done on a laboratory quantum discriminator, the functional diagram of which contained a known element set for rubidium frequency standard on a gas cell. The discriminator was placed in the three identical pairs of Helmholtz coils, 50 cm in diameter, which created a working magnetic field (10 μT, 3 μT, and 1 μT) in the area of the gas cell. Helmholtz coils were connected to alternating voltage sources to create a rotating magnetic field relative to the normal to the direction of the pumping light. To weaken external magnetic noise and inhomogeneities of the laboratory magnetic field, the entire system was placed in a magnetic shield with a screening factor of ~ 103, which practically made it possible to exclude the effect of the residual field on the measurements accuracy. The main experimental results are formulated as follows: the orientational frequency shift of the 0-0 radio-optical resonance does not depend on the magnitude of the working magnetic field and is linearly related to the pumping light intensity; when the working magnetic field is oriented normal to the quantum discriminator optical axis, the tensor and scalar components of the light shift have equal (positive) signs, which at any temperature of the filter-cell leads to their impossible compensation; when the working magnetic field is oriented along the quantum discriminator optical axis, the tensor and scalar components of the light shift have opposite signs, which at the corresponding temperature of the filter-cell leads to their possible (partial) compensation.