Advanced Optical Technologies

Towards a compact, optically interrogated, cold-atom microwave clock

Rachel Elvin, Michael W. Wright, Ben Lewis, Brendan Keliehor, Alan Bregazzi, J. P. McGilligan, Aidan S. Arnold, Paul F. Griffin, Erling Riis

Published Sep 7, 2019• 7 citations
Publisher

Abstract

Abstract A compact platform for cold atoms opens a range of exciting possibilities for portable, robust and accessible quantum sensors. In this work, we report on the development of a cold-atom microwave clock in a small package. Our work utilises the grating magneto-optical trap and high-contrast coherent population trapping in the lin ⊥ $\perp $ lin polarisation scheme. We optically probe the atomic ground-state splitting of cold 87Rb atoms using a Ramsey-like sequence whilst the atoms are in free-fall. We have measured a short-term fractional frequency stability of 5 × 10 − 11 / τ $5{\times}{10}^{-11}/\sqrt{\tau }$ with a projected quantum projection noise limit at the 10 − 13 / τ ${10}^{-13}/\sqrt{\tau }$ level.

DOI
10.1515/aot-2020-0022

Related papers

Cold-atom clock based on a diffractive optic

R. Elvin, G. W. Hoth, M. Wright +5 more

Clocks based on cold atoms offer unbeatable accuracy and long-term stability, but their use in portable quantum technologies is hampered by a large physical footprint. Here, we use the compact optical layout of a grating magneto-optical trap (gMOT) for a precise frequency reference. The gMOT collects $10^7$ $^{87}$Rb atoms, which are subsequently cooled to $20\,μ$K in optical molasses. We optically probe the microwave atomic ground-state splitting using lin$\perp$lin polarised coherent population trapping and a Raman-Ramsey sequence. With ballistic drop distances of only $0.5\,$mm, the measured short-term fractional frequency stability is $2 \times 10 ^{-11} /\sqrtτ$.

arXiv:1909.04361•Optics Express•Dec 5, 2019•54 citations

A compact cold-atom double-resonance clock

Alan Bregazzi, Etienne Batori, Ben Lewis +4 more

We present a demonstration of a cold-atom optical-microwave double resonance (DR) Ramsey clock utilising an additively manufactured loop-gap-resonator cavity and grating magneto-optical trap (GMOT). The use of additive manufacturing allows for complex cavity structures, more difficult to produce with traditional machining techniques, while the GMOT architecture significantly simplifies the optical system required to trap and cool the atomic sample. In the current demonstration a single laser is used to trap < 3 × 106 87Rb atoms, cool them to below 10 µK, optically pump and read-out state populations of the atoms after microwave interrogation. A Ramsey-type interrogation scheme is employed with an empirically evaluated optimum free evolution time of 10 ms, limited by the loss of signal due to atoms falling out of the read-out beam. We demonstrate a short-term stability of < 2×10−11τ−1/2, in reasonable agreement with the predicted short-term stability based on the signal to noise ratio of the measured Ramsey fringes. Excellent field homogeneity of the cavity microwave field is demonstrated though Rabi oscillations, while almost complete optical pumping and good field orientation is evidenced by Zeeman spectroscopy of the ground-state hyperfine energy levels. This work is a novel approach towards more compact and portable cold-atom microwave clocks with significant potential for further miniaturization of the system.

Optical and Quantum Sensing and Precision Metrology II•Mar 8, 2023•0 citations

Progress of a compact microwave clock based on atoms cooled with a diffractive optic

Rachel Elvin, Gregory W. Hoth, Michael W. Wright +6 more

An atomic clock based on a compact source of cold atoms and coherent population trapping (CPT) is an encouraging goal for future low-volume atomic frequency references. Our experiment seeks to investigate the performance of such a system by applying CPT in a high-contrast lin⊥lin polarisation scheme to our 87Rb grating magneto optical trap (GMOT) apparatus. In this paper, we report on our progress of improving short- term stability of our cold-atom CPT apparatus. Our recent measurements have shown a short-term stability of 5 x 10-11/√τ, with the ability to average down for times τ>100s.

SPIE eBooks•Feb 25, 2020•0 citations

A cold-atom Ramsey clock with a low volume physics package

Alan Bregazzi, Etienne Batori, Ben Lewis +4 more

We demonstrate a Ramsey-type microwave clock interrogating the 6.835 GHz ground-state transition in cold [Formula: see text]Rb atoms loaded from a grating magneto-optical trap (GMOT) enclosed in an additively manufactured loop-gap resonator microwave cavity. A short-term stability of [Formula: see text] is demonstrated, in reasonable agreement with predictions from the signal-to-noise ratio of the measured Ramsey fringes. The cavity-grating package has a volume of [Formula: see text]67 cm[Formula: see text], ensuring an inherently compact system while the use of a GMOT drastically simplifies the optical requirements for laser cooled atoms. This work is another step towards the realisation of highly compact portable cold-atom frequency standards.

arXiv:2305.02944•Scientific Reports•Jan 9, 2024•23 citations

A compact cold atom cavity clock

Alan Bregazzi, Etienne Batori, Ben Lewis +4 more

Abstract A sample of laser cooled atoms are created inside an additively manufactured loop-gap microwave cavity using a grating magneto-optic trap requiring only a single laser cooling beam. Using a Ramsey excitation scheme with free evolution times of up to 20 ms and based on the 87Rb ground-state clock transition, we demonstrate a short-term stability of 1.5×10−11 τ −1/2, averaging down to 2×10−12 after 100 s. The short-term stability limit is found to be dominated by the signal to noise ratio of the Ramsey fringes while for longer timescales the limitation is magnetic field noise due to the experiment being magnetically unshielded. Potential improvements to the setup and its operation point to a viable route forward for a miniaturised atomic microwave clock.

Journal of Physics Conference Series•Nov 1, 2024•0 citations

High-performance coherent population trapping clock based on laser-cooled atoms

Xiaochi Liu, Ning Ru, Junyi Duan +3 more

We present a coherent population trapping clock system based on laser-cooled 87Rb atoms. The clock consists of a frequency-stabilized CPT interrogation laser and a cooling laser as well as a compact magneto-optical trap, a high-performance microwave synthesizer, and a signal detection system. The resonance signal in the continuous wave regime exhibits an absorption contrast of ∼ 50%. In the Ramsey interrogation method, the linewidth of the central fringe is 31.25 Hz. The system achieves fractional frequency stability of 2.4 × 10 − 11 / τ , which goes down to 1.8 × 10−13 at 20000 s. The results validate that cold atom interrogation can improve the long-term frequency stability of coherent population trapping clocks and holds the potential for developing compact/miniature cold atoms clocks.

Chinese Physics B•Oct 6, 2021•8 citations
Abstract A compact platform for cold atoms opens a range of exciting possibilities for portable, robust and accessible quantum sensors. In this work, we report on the development of a cold-atom microwave clock in a small package. Our work utilises the grating magneto-optical trap and high-contrast coherent population trapping in the lin ⊥ ⊥\perp ⊥ lin polarisation scheme. We optically probe the atomic ground-state splitting of cold 87Rb atoms using a Ramsey-like sequence whilst the atoms are in free-fall. We have measured a short-term fractional frequency stability of 5 × 10 − 11 / τ 5×10−11/τ5{\times}{10}^{-11}/\sqrt{\tau }5×10−11/τ​ with a projected quantum projection noise limit at the 10 − 13 / τ 10−13/τ{10}^{-13}/\sqrt{\tau }10−13/τ​ level.
Clocks based on cold atoms offer unbeatable accuracy and long-term stability, but their use in portable quantum technologies is hampered by a large physical footprint. Here, we use the compact optical layout of a grating magneto-optical trap (gMOT) for a precise frequency reference. The gMOT collects 10710^7107 87^{87}87Rb atoms, which are subsequently cooled to 20 μ20\,μ20μK in optical molasses. We optically probe the microwave atomic ground-state splitting using lin⊥\perp⊥lin polarised coherent population trapping and a Raman-Ramsey sequence. With ballistic drop distances of only 0.5 0.5\,0.5mm, the measured short-term fractional frequency stability is 2×10−11/τ2 \times 10 ^{-11} /\sqrtτ2×10−11/τ​.
We present a demonstration of a cold-atom optical-microwave double resonance (DR) Ramsey clock utilising an additively manufactured loop-gap-resonator cavity and grating magneto-optical trap (GMOT). The use of additive manufacturing allows for complex cavity structures, more difficult to produce with traditional machining techniques, while the GMOT architecture significantly simplifies the optical system required to trap and cool the atomic sample. In the current demonstration a single laser is used to trap < 3 × 106 87Rb atoms, cool them to below 10 µK, optically pump and read-out state populations of the atoms after microwave interrogation. A Ramsey-type interrogation scheme is employed with an empirically evaluated optimum free evolution time of 10 ms, limited by the loss of signal due to atoms falling out of the read-out beam. We demonstrate a short-term stability of < 2×10−11τ−1/2, in reasonable agreement with the predicted short-term stability based on the signal to noise ratio of the measured Ramsey fringes. Excellent field homogeneity of the cavity microwave field is demonstrated though Rabi oscillations, while almost complete optical pumping and good field orientation is evidenced by Zeeman spectroscopy of the ground-state hyperfine energy levels. This work is a novel approach towards more compact and portable cold-atom microwave clocks with significant potential for further miniaturization of the system.
An atomic clock based on a compact source of cold atoms and coherent population trapping (CPT) is an encouraging goal for future low-volume atomic frequency references. Our experiment seeks to investigate the performance of such a system by applying CPT in a high-contrast lin⊥lin polarisation scheme to our 87Rb grating magneto optical trap (GMOT) apparatus. In this paper, we report on our progress of improving short- term stability of our cold-atom CPT apparatus. Our recent measurements have shown a short-term stability of 5 x 10-11/√τ, with the ability to average down for times τ>100s.
We demonstrate a Ramsey-type microwave clock interrogating the 6.835 GHz ground-state transition in cold [Formula: see text]Rb atoms loaded from a grating magneto-optical trap (GMOT) enclosed in an additively manufactured loop-gap resonator microwave cavity. A short-term stability of [Formula: see text] is demonstrated, in reasonable agreement with predictions from the signal-to-noise ratio of the measured Ramsey fringes. The cavity-grating package has a volume of [Formula: see text]67 cm[Formula: see text], ensuring an inherently compact system while the use of a GMOT drastically simplifies the optical requirements for laser cooled atoms. This work is another step towards the realisation of highly compact portable cold-atom frequency standards.
Abstract A sample of laser cooled atoms are created inside an additively manufactured loop-gap microwave cavity using a grating magneto-optic trap requiring only a single laser cooling beam. Using a Ramsey excitation scheme with free evolution times of up to 20 ms and based on the 87Rb ground-state clock transition, we demonstrate a short-term stability of 1.5×10−11 τ −1/2, averaging down to 2×10−12 after 100 s. The short-term stability limit is found to be dominated by the signal to noise ratio of the Ramsey fringes while for longer timescales the limitation is magnetic field noise due to the experiment being magnetically unshielded. Potential improvements to the setup and its operation point to a viable route forward for a miniaturised atomic microwave clock.
We present a coherent population trapping clock system based on laser-cooled 87Rb atoms. The clock consists of a frequency-stabilized CPT interrogation laser and a cooling laser as well as a compact magneto-optical trap, a high-performance microwave synthesizer, and a signal detection system. The resonance signal in the continuous wave regime exhibits an absorption contrast of ∼ 50%. In the Ramsey interrogation method, the linewidth of the central fringe is 31.25 Hz. The system achieves fractional frequency stability of 2.4 × 10 − 11 / τ , which goes down to 1.8 × 10−13 at 20000 s. The results validate that cold atom interrogation can improve the long-term frequency stability of coherent population trapping clocks and holds the potential for developing compact/miniature cold atoms clocks.