Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

Optical cavity with intracavity two-photon absorption

Kevin K. Lehmann

Published Aug 17, 2020• 7 citations
Publisher

Abstract

This paper presents a theoretical analysis of the optical properties of an optical cavity with both one- and two-photon intracavity absorption loss, without saturation. The cavity two-photon absorption loss per pass is assumed to be small, but otherwise the analysis is general. Analytical results for the cavity transmission as a function of cavity parameters, linear and two-photon intracavity loss, and detuning from resonance are derived and limiting cases discussed. Extraction of the two-photon loss from both cavity ring-down and cavity-enhanced absorption spectroscopy methods is analyzed and the predicted shot-noise limited sensitivities derived and compared. Numerical results are computed using the parameters of a recent experimental intracavity measurement of two-photon absorption of nitrous oxide. The results will be useful in the design and interpretation of cavity-enhanced, two-photon absorption spectroscopy.

DOI
10.1364/josab.392539

Related papers

Super-Resonant Intracavity Coherent Absorption

P. Malara, Carlo Edoardo Campanella, A. Giorgini +3 more

The capability of optical resonators to extend the effective radiation-matter interaction length originates from a multipass effect, hence is intrinsically limited by the resonator's quality factor. Here, we show that this constraint can be overcome by combining the concepts of resonant interaction and coherent perfect absorption (CPA). We demonstrate and investigate super-resonant coherent absorption in a coupled Fabry-Perot (FP)/ring cavity structure. At the FP resonant wavelengths, the described phenomenon gives rise to split modes with a nearly-transparent peak and a peak whose transmission is exceptionally sensitive to the intracavity loss. For small losses, the effective interaction pathlength of these modes is proportional respectively to the ratio and the product of the individual finesse coefficients of the two resonators. The results presented extend the conventional definition of resonant absorption and point to a way of circumventing the technological limitations of ultrahigh-quality resonators in spectroscopy and optical sensing schemes.

arXiv:1605.00389•Scientific Reports•Jul 1, 2016•11 citations

Quantum limits and robustness of nonlinear intracavity absorption spectroscopy

John K. Stockton, Ari K. Tuchman

We investigate the limits of intracavity absorption spectroscopy with nonlinear media. Using a common theoretical framework, we compare the detection of a trace gas within (i) an undriven cavity with gain near and above threshold; (ii) a driven cavity with gain kept just below threshold; and (iii) a cavity driven close to the saturation point of a saturable absorber. These phase-transition-based metrology methods are typically quantum limited by spontaneous emission, and we compare them to the empty-cavity shot-noise-limited case. Although the fundamental limits achievable with nonlinear media do not surpass the empty-cavity limits, we show that nonlinear methods are more robust against certain technical noise models. This recognition may have applications in spectrometer design for devices operating in nonideal field environments.

arXiv:0810.4209•Physical Review A•Jan 27, 2009•2 citations

Enhancement of photon antibunching by passive interferometry

Yujiang Qu, Min Xiao, G. S. Holliday +2 more

Photon antibunching in intracavity second-harmonic generation and intracavity atomic absorption inside a high-Q optical cavity is discussed. A linearized description of quantum dynamics in the weak-field limit is used because the system size, as characterized by the number of photons ${\mathit{n}}_{0}$ needed to probe the nonlinearity of the system, is often quite large for realistic parameters. In both cases standard results are recalled that demonstrate that antibunching is a small effect given by ${\mathit{g}}^{(2)}$(0)-1\ensuremath{\approxeq}-1/${\mathit{n}}_{0}$ for large values of ${\mathit{n}}_{0}$. We show that when higher-order terms that are usually ignored in linearized treatments are retained, ${\mathit{g}}^{(2)}$(0) satisfies the lower bound ${\mathit{g}}^{(2)}$(0)\ensuremath{\ge}0 even for small values of ${\mathit{n}}_{0}$. It is further shown that by employing a high-Q cavity to suppress the coherent part of the spectrum of field fluctuations, perfect antibunching can be achieved even for large systems. Conditions under which this is possible are derived and curves are presented to illustrate the behavior.

Physical Review A•Apr 1, 1992•10 citations

Understanding the sensitivity of cavity-enhanced absorption spectroscopy: pathlength enhancement versus noise suppression

Bin Ouyang, Roderic L. Jones

Cavity-enhanced absorption spectroscopy is now widely used as an ultrasensitive technique in observing weak spectroscopic absorptions. Photons inside the cavity are reflected back and forth between the mirrors with reflectivities R close to one and thus (on average) exploit an absorption pathlength L that is 1/(1 − R ) longer than a single pass measurement. As suggested by the Beer-Lambert law, this increase in L results in enhanced absorbance A (given by αL with α being the absorption coefficient) which in turn favours the detection of weak absorptions. At the same time, however, only (1 − R ) of the incident light can enter the cavity [assuming that mirror transmission T is equal to (1 − R )], so that the reduction in transmitted light intensity Δ I caused by molecular absorption equates to that would be obtained if in fact no cavity were present . The enhancement in A = Δ I / I , where I is the total transmitted light intensity, achievable from CEAS therefore comes not from an increase in Δ I , but a sharp decrease in I. In this paper, we calculate the magnitudes of these two terms before and after a cavity is introduced, and aim at interpreting the sensitivity improvement offered by cavity-enhanced absorption spectroscopy from this observable-oriented (i.e. Δ I and I ) perspective. It is first shown that photon energy stored in the cavity is at best as intense as the input light source, implying that any absorbing sample within the cavity is exposed to the same or even lower light intensity after the cavity is formed. As a consequence, the intensity of the light absorbed or scattered by the sample, which corresponds to the Δ I term aforementioned, is never greater than would be the case in a single pass measurement. It is then shown that while this “numerator” term is not improved, the “denominator” term, I , is reduced considerably; therefore, the increase in contrast ratio Δ I / I is solely contributed by the attenuation of transmitted background light I and is ultimately down to the suppression of any measurement noise that is associated with it. The noise component that is most effectively suppressed is the type whose magnitude scales linearly with light intensity I , as is typical of noise caused by environmental instabilities, followed by the shot noise which scales as square root of I . No suppression is achievable for noise sources that are independent of I , a notable example being the thermal noise of a detector or of detection electronics. The usefulness of this “noise suppression” argument is that it links the sensitivity gain offered by a cavity with the property of measurement noise present in the system, and clearly suggests that the achievable sensitivity is dependent on how efficient the various noise components are “suppressed” by the cavity.

Applied Physics B•Sep 17, 2012•33 citations

Quantum Optical Analysis of Atomic Density and Refractive Index Employing Cavity Enhanced Absorption Spectroscopy

Surabhi Yadav, Suman Dudeja, Aranya B. Bhattacherjee

We propose a novel cavity enhanced absorption spectroscopic technique to sensitively measure atomic density and refractive index of a sample gas.We theoretically investigate the quantum optical response of a gas of atoms enclosed inside an optical cavity to a probe beam that passes through it. In particular, we study the intracavity spectra, the output spectra and the spectra of the fluctuations. We show that the response of the system is sensitive to small changes in the number of atoms and the refractive index.

Journal of Atomic Molecular Condensed Matter and Nano Physics•Oct 31, 2021•0 citations

Cross correlations between fluorescent and transmitted photons in single-atom cavity-enhanced absorption

Perry R. Rice, Xiaoyi Wang, H. J. Carmichael

We study a single two-level atom interacting on resonance with a weakly driven optical cavity mode. In earlier work on this system we calculated the degree of second-order coherence, the optical spectrum, and the spectrum of squeezing for both the transmitted light and fluorescence out the sides of the cavity.1,2 We present results for the cross-correlation functions that determine joint probabilities for a photodetection in transmission (fluorescence) followed by a photodetection in fluorescence (transmission). We compute these correlation functions numerically for arbitrary values of the three rates that govern the system dynamics: the atomic decay rate γ to modes other than the cavity mode, the photon escape rate from the cavity 2K, and the atom-field coupling constant g. Analytical results provide insight for the following limits of the parameters: (1) the bad-cavity limit, κ/γ→∞,κ/g→∞,g2/κγ constant; (2) the atomic-loss limit, κ/γ→0,κ/g→0,γ/g constant; (3) the cavity-loss limit, γ/κ→0,γ/g→0,g/κ constant; and (4) the good-cavity limit, k/γ→0,k/g→0,g2/κγ constant. In the bad-cavity limit the cross-correlation functions are symmetric with respect to the order of detection in transmission and fluorescence; in general they are not symmetric.

Annual Meeting Optical Society of America•Jan 1, 1988•1 citation
This paper presents a theoretical analysis of the optical properties of an optical cavity with both one- and two-photon intracavity absorption loss, without saturation. The cavity two-photon absorption loss per pass is assumed to be small, but otherwise the analysis is general. Analytical results for the cavity transmission as a function of cavity parameters, linear and two-photon intracavity loss, and detuning from resonance are derived and limiting cases discussed. Extraction of the two-photon loss from both cavity ring-down and cavity-enhanced absorption spectroscopy methods is analyzed and the predicted shot-noise limited sensitivities derived and compared. Numerical results are computed using the parameters of a recent experimental intracavity measurement of two-photon absorption of nitrous oxide. The results will be useful in the design and interpretation of cavity-enhanced, two-photon absorption spectroscopy.
The capability of optical resonators to extend the effective radiation-matter interaction length originates from a multipass effect, hence is intrinsically limited by the resonator's quality factor. Here, we show that this constraint can be overcome by combining the concepts of resonant interaction and coherent perfect absorption (CPA). We demonstrate and investigate super-resonant coherent absorption in a coupled Fabry-Perot (FP)/ring cavity structure. At the FP resonant wavelengths, the described phenomenon gives rise to split modes with a nearly-transparent peak and a peak whose transmission is exceptionally sensitive to the intracavity loss. For small losses, the effective interaction pathlength of these modes is proportional respectively to the ratio and the product of the individual finesse coefficients of the two resonators. The results presented extend the conventional definition of resonant absorption and point to a way of circumventing the technological limitations of ultrahigh-quality resonators in spectroscopy and optical sensing schemes.
We investigate the limits of intracavity absorption spectroscopy with nonlinear media. Using a common theoretical framework, we compare the detection of a trace gas within (i) an undriven cavity with gain near and above threshold; (ii) a driven cavity with gain kept just below threshold; and (iii) a cavity driven close to the saturation point of a saturable absorber. These phase-transition-based metrology methods are typically quantum limited by spontaneous emission, and we compare them to the empty-cavity shot-noise-limited case. Although the fundamental limits achievable with nonlinear media do not surpass the empty-cavity limits, we show that nonlinear methods are more robust against certain technical noise models. This recognition may have applications in spectrometer design for devices operating in nonideal field environments.
Photon antibunching in intracavity second-harmonic generation and intracavity atomic absorption inside a high-Q optical cavity is discussed. A linearized description of quantum dynamics in the weak-field limit is used because the system size, as characterized by the number of photons n0{\mathit{n}}_{0}n0​ needed to probe the nonlinearity of the system, is often quite large for realistic parameters. In both cases standard results are recalled that demonstrate that antibunching is a small effect given by g(2){\mathit{g}}^{(2)}g(2)(0)-1\ensuremath{\approxeq}-1/n0{\mathit{n}}_{0}n0​ for large values of n0{\mathit{n}}_{0}n0​. We show that when higher-order terms that are usually ignored in linearized treatments are retained, g(2){\mathit{g}}^{(2)}g(2)(0) satisfies the lower bound g(2){\mathit{g}}^{(2)}g(2)(0)\ensuremath{\ge}0 even for small values of n0{\mathit{n}}_{0}n0​. It is further shown that by employing a high-Q cavity to suppress the coherent part of the spectrum of field fluctuations, perfect antibunching can be achieved even for large systems. Conditions under which this is possible are derived and curves are presented to illustrate the behavior.
Cavity-enhanced absorption spectroscopy is now widely used as an ultrasensitive technique in observing weak spectroscopic absorptions. Photons inside the cavity are reflected back and forth between the mirrors with reflectivities R close to one and thus (on average) exploit an absorption pathlength L that is 1/(1 − R ) longer than a single pass measurement. As suggested by the Beer-Lambert law, this increase in L results in enhanced absorbance A (given by αL with α being the absorption coefficient) which in turn favours the detection of weak absorptions. At the same time, however, only (1 − R ) of the incident light can enter the cavity [assuming that mirror transmission T is equal to (1 − R )], so that the reduction in transmitted light intensity Δ I caused by molecular absorption equates to that would be obtained if in fact no cavity were present . The enhancement in A = Δ I / I , where I is the total transmitted light intensity, achievable from CEAS therefore comes not from an increase in Δ I , but a sharp decrease in I. In this paper, we calculate the magnitudes of these two terms before and after a cavity is introduced, and aim at interpreting the sensitivity improvement offered by cavity-enhanced absorption spectroscopy from this observable-oriented (i.e. Δ I and I ) perspective. It is first shown that photon energy stored in the cavity is at best as intense as the input light source, implying that any absorbing sample within the cavity is exposed to the same or even lower light intensity after the cavity is formed. As a consequence, the intensity of the light absorbed or scattered by the sample, which corresponds to the Δ I term aforementioned, is never greater than would be the case in a single pass measurement. It is then shown that while this “numerator” term is not improved, the “denominator” term, I , is reduced considerably; therefore, the increase in contrast ratio Δ I / I is solely contributed by the attenuation of transmitted background light I and is ultimately down to the suppression of any measurement noise that is associated with it. The noise component that is most effectively suppressed is the type whose magnitude scales linearly with light intensity I , as is typical of noise caused by environmental instabilities, followed by the shot noise which scales as square root of I . No suppression is achievable for noise sources that are independent of I , a notable example being the thermal noise of a detector or of detection electronics. The usefulness of this “noise suppression” argument is that it links the sensitivity gain offered by a cavity with the property of measurement noise present in the system, and clearly suggests that the achievable sensitivity is dependent on how efficient the various noise components are “suppressed” by the cavity.
We propose a novel cavity enhanced absorption spectroscopic technique to sensitively measure atomic density and refractive index of a sample gas.We theoretically investigate the quantum optical response of a gas of atoms enclosed inside an optical cavity to a probe beam that passes through it. In particular, we study the intracavity spectra, the output spectra and the spectra of the fluctuations. We show that the response of the system is sensitive to small changes in the number of atoms and the refractive index.
We study a single two-level atom interacting on resonance with a weakly driven optical cavity mode. In earlier work on this system we calculated the degree of second-order coherence, the optical spectrum, and the spectrum of squeezing for both the transmitted light and fluorescence out the sides of the cavity.1,2 We present results for the cross-correlation functions that determine joint probabilities for a photodetection in transmission (fluorescence) followed by a photodetection in fluorescence (transmission). We compute these correlation functions numerically for arbitrary values of the three rates that govern the system dynamics: the atomic decay rate γ to modes other than the cavity mode, the photon escape rate from the cavity 2K, and the atom-field coupling constant g. Analytical results provide insight for the following limits of the parameters: (1) the bad-cavity limit, κ/γ→∞,κ/g→∞,g2/κγ constant; (2) the atomic-loss limit, κ/γ→0,κ/g→0,γ/g constant; (3) the cavity-loss limit, γ/κ→0,γ/g→0,g/κ constant; and (4) the good-cavity limit, k/γ→0,k/g→0,g2/κγ constant. In the bad-cavity limit the cross-correlation functions are symmetric with respect to the order of detection in transmission and fluorescence; in general they are not symmetric.