Comparison of absorption and fluorescence in a nano-cell containing Rb vapor with other Rb nano-cells with addition of neon gas is presented. It is shown that the effect of collapse and revival of Dicke-type narrowing occurs for Rb nanocells containing N2 as buffer gas under 6 and 20 Torr pressure for the thickness L = λ /2 and L = where λ is the resonant λ, laser wavelength 794 nm (D1 line). Particularly for 6 Torr the line-width of the transmission spectrum for the thickness L =λ/2 is 2 times narrower than that for L = λ. For an ordinary Rb cell with L = 0.1 - 10 cm with addition of buffer gas, the velocity selective optical pumping/saturation (VSOP) resonances in saturated absorption spectra are fully suppressed when the buffer gas pressure > 0.5 Torr. A spectacular difference is that for L = λ, VSOP resonances located at the atomic transitions are still observable even when Ne pressure is ≥ 6 Torr. Narrowband fluorescence spectra of a nano-cell with L = λ/2 can be used as a convenient tool for online buffer gas pressure monitoring for the conditions when ordinary pressure gauges are unusable. Comparison of electromagnetically induced transparency (EIT) effect in a nano-cell filled with pure (without a buffer gas) Rb with another nano-cell, where buffer gas nitrogen is added, is presented. The use of N2 gas inside Rb nano-cells strongly extends the range of coupling laser detunings in which it is still possible to form EIT resonance.
For precision atomic magnetometry, inert buffer gas is included in alkali-metal vapor cells to significantly broaden hyperfine transitions, which facilitates optical pumping and reduces diffusive relaxation, while also providing non-radiative excited state quenching. We show low-buffer gas pressure (below 50 Torr) alkali vapor cells with resolved hyperfine manifolds can also yield high-performance magnetometers. For high polarization in 87Rb, we optically pump F=2 states with narrow linewidth σ+ light, while tuning a probe beam to depopulate F=1 states (Δν=6.8 GHz from F=2). The probe tuning then also provides F=2 detection with high optical rotation and low probe broadening; we demonstrate top-bottom gradiometry, within a single 25 Torr, 0.5 cc cell, that yields an Earth's field free-precession magnetometer sensitivity of 18 fT/Hz with a 1 kHz bandwidth, as well as RF magnetometer sensitivity of 12 fT/Hz in a small band about 110 kHz.
Spin-exchange-relaxation-free (SERF) optical atomic magnetometers are facing the challenges of dramatic decrease of sensitivity when the alkali vapor cells become small. This paper focuses on the sensitivity improvement of the chip-scale atomic magnetometer (CSAM) by changing buffer-gas pressures inside the microfabricated vapor cells. The rubidium vapor cells with three different buffer-gas pressures were tested in the SERF magnetometer. The influences of vapor cell temperature and pumping laser power on the device sensitivity are also characterized for further optimization. Results show that the three atomic vapor cells, with N2buffer-gas pressure of 0.20, 0.88, and 2.35 amg, have sensitivities of 900, 500, and 150 fT/Hz1/2, respectively. Results indicated that when the alkali vapor cells continue to be smaller, high buffer-gas pressure would provide an effective way to reduce the wall collision and improve the performance of CSAMs.