Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

RaEl

The noise of rapid-action superconductor bolometers

A. D. Tkachenko, I. A. Khrebtov

Published Jan 1, 1990• 0 citations
OpenAlex

Related papers

Normal metal–insulator–superconductor junction technology for bolometers

Daniel R. Schmidt, William Duncan, K. D. Irwin +3 more

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment•Jan 5, 2006•5 citations

Investigation of the low-frequency noise of a superconducting bolometer

Г. А. Зайцев, I. A. Khrebtov

RaEl•May 1, 1978•0 citations

Superconductive bolometers for submillimeter wavelengths

John L. Clarke, G. I. Hoffer, P. L. Richards +1 more

Three types of composite superconductive bolometers are described in which the temperature-sensitive element is a superconducting film at the transition temperature, a superconductor–normal metal–superconductor Josephson junction, or a superconductor–insulator–normal metal quasiparticle tunneling junction. The temperature-sensitive element is evaporated onto a sapphire substrate on the reverse side of which is a bismuth film to absorb the submillimeter radiation. The noise limitations of each type of bolometer are calculated. The fabrication and measured performance of the transition-edge bolometer and the Josephson-junction bolometer are described. The best electrical (noise-equivalent power) NEP obtained with a transition-edge bolometer fabricated on a 4×4×0.005-mm sapphire substrate is (1.7±0.1) ×10−15 W Hz−1/2 at 2 Hz at an operating temperature of 1.27 K. This NEP is within a factor of 2 of the thermal noise limit. The effective absorptivity of the bismuth film is measured to be 0.47±0.05, and the corresponding detectivity D* is calculated to be (1.1±0.1) ×1014 cm W−1 Hz1/2. Suggestions are made for further improvements in sensitivity.

Journal of Applied Physics•Dec 1, 1977•142 citations

Analysys of the concept of a superconducing bolometer with rf readout

Nikolay N. Abramov

The concept of a superconducting transition-edge bolometer with rf readout, which was proposed in a number of earlier publications, is analyzed. It is shown that such a device cannot in fact operate at the edge of the superconducting transition, and nonequilibrium effects in the superconductor play the major role in its response to the electromagnetic action. A mathematical model is developed, which explains qualitatively the experimental results reported earlier and indicating an unstable response to the action of a readout (pump) signal. The possibility of obtaining a stable response with an optimal choice of parameters of the device is also demonstrated.

Technical Physics•Feb 1, 2016•0 citations

Superconducting noise bolometer as a direct detector

Andrew G. Semenov, Heinz‐Wilhelm Hübers, K. Ilin +2 more

•Jan 1, 2005•0 citations

Concept of a mixer based on a cold-electron bolometer

Michael A. Tarasov, L. S. Kuzmin

A phase-sensitive terahertz heterodyne mixer of a new type based on a cold-electron bolometer is proposed. In this mixer, a normal-metal thin-film absorber is connected to a planar antenna via superconductor-insulator-normal metal (SIN) tunnel junctions, thus forming a SINIS structure. The SINIS mixer combines the advantages of a hot-electron bolometer (HEB), such as a high signal frequency at a small local oscillator power, with the advantages of an SIS mixer, including low noise level, a high intermediate frequency, and wide working temperature range (up to a critical temperature of the superconductor). In contrast to the HEB and SIS mixers, the proposed device is less sensitive to external magnetic noise and exhibits no additional noise related to the superconducting transition and the Josephson effect.

Journal of Experimental and Theoretical Physics Letters•May 1, 2005•6 citations
Three types of composite superconductive bolometers are described in which the temperature-sensitive element is a superconducting film at the transition temperature, a superconductor–normal metal–superconductor Josephson junction, or a superconductor–insulator–normal metal quasiparticle tunneling junction. The temperature-sensitive element is evaporated onto a sapphire substrate on the reverse side of which is a bismuth film to absorb the submillimeter radiation. The noise limitations of each type of bolometer are calculated. The fabrication and measured performance of the transition-edge bolometer and the Josephson-junction bolometer are described. The best electrical (noise-equivalent power) NEP obtained with a transition-edge bolometer fabricated on a 4×4×0.005-mm sapphire substrate is (1.7±0.1) ×10−15 W Hz−1/2 at 2 Hz at an operating temperature of 1.27 K. This NEP is within a factor of 2 of the thermal noise limit. The effective absorptivity of the bismuth film is measured to be 0.47±0.05, and the corresponding detectivity D* is calculated to be (1.1±0.1) ×1014 cm W−1 Hz1/2. Suggestions are made for further improvements in sensitivity.
The concept of a superconducting transition-edge bolometer with rf readout, which was proposed in a number of earlier publications, is analyzed. It is shown that such a device cannot in fact operate at the edge of the superconducting transition, and nonequilibrium effects in the superconductor play the major role in its response to the electromagnetic action. A mathematical model is developed, which explains qualitatively the experimental results reported earlier and indicating an unstable response to the action of a readout (pump) signal. The possibility of obtaining a stable response with an optimal choice of parameters of the device is also demonstrated.
A phase-sensitive terahertz heterodyne mixer of a new type based on a cold-electron bolometer is proposed. In this mixer, a normal-metal thin-film absorber is connected to a planar antenna via superconductor-insulator-normal metal (SIN) tunnel junctions, thus forming a SINIS structure. The SINIS mixer combines the advantages of a hot-electron bolometer (HEB), such as a high signal frequency at a small local oscillator power, with the advantages of an SIS mixer, including low noise level, a high intermediate frequency, and wide working temperature range (up to a critical temperature of the superconductor). In contrast to the HEB and SIS mixers, the proposed device is less sensitive to external magnetic noise and exhibits no additional noise related to the superconducting transition and the Josephson effect.