Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Mitigating back-action in parametric quantum amplifiers

A. Metelmann, Archana Kamal

Published Mar 15, 2021• 0 citations
OpenAlex

Related papers

Signal-to-pump back action and self-oscillation in double-pump Josephson parametric amplifier

Archana Kamal, Adam Henry Marblestone, Michel Devoret

We present the theory of a Josephson parametric amplifier employing two-pump sources. Our calculations are based on input-output theory, and can easily be generalized to any coupled system involving parametric interactions. We analyze the operation of the device, taking into account the feedback introduced by the reaction of the signal and noise on the pump power, and in this framework, compute the response functions of interest---signal and idler gains, internal gain of the amplifier, and self-oscillation signal amplitude. To account for this back action between signal and pump, we adopt a mean-field approach and self-consistently explore the boundary between amplification and self-oscillation. The coincidence of bifurcation and self-oscillation thresholds reveals that the origin of coherent emission of the amplifier lies in the multiwave mixing of the noise components. Incorporation of the back action leads the system to exhibit hysteresis, dependent on parameters such as temperature and detuning from resonance. Our analysis also shows that the resonance condition itself changes in the presence of back action and this can be understood in terms of the change in plasma frequency of the junction. The potential of the double-pump amplifier for quantum-limited measurements and as a squeezer is also discussed.

arXiv:0902.0007•Physical Review B•May 13, 2009•69 citations

Simulation of Quantum Parametric Amplifiers

Keith Krause

•May 19, 2021•0 citations

Non-classical properties of quantum amplifiers

Stig Stenholm

Hyperfine Interactions•Dec 1, 1987•1 citation

Amplified quantum nondemolition measurements of optical quadratures using quadratic nonlinearity

Dariya Salykina, V. S. Liamin, Polina R. Sharapova +1 more

Quantum non-demolition (QND) measurement is a special technique that allows to evade quantum back-action. In this paper, we propose a new QND measurement scheme of the optical field quadratures based on the non-degenerate optical parametric amplifier. We show that for a proper set of parameters, this scheme can realize a new type of QND measurement, where the quadrature of interest is amplified, but still does not subject to any back action.

arXiv:2507.15508•Physical Review A•Mar 2, 2026•1 citation

Saturation of a quantum parametric amplifier in the pulse mode

N. T. Cherpak, Ya.L. Shamfarov

Radiophysics and Quantum Electronics•Jan 1, 1969•0 citations

Improving the Quality of Heisenberg Back-Action of Qubit Measurements made with Parametric Amplifiers

Katrina Sliwa

•Jan 1, 2016•4 citations
We present the theory of a Josephson parametric amplifier employing two-pump sources. Our calculations are based on input-output theory, and can easily be generalized to any coupled system involving parametric interactions. We analyze the operation of the device, taking into account the feedback introduced by the reaction of the signal and noise on the pump power, and in this framework, compute the response functions of interest---signal and idler gains, internal gain of the amplifier, and self-oscillation signal amplitude. To account for this back action between signal and pump, we adopt a mean-field approach and self-consistently explore the boundary between amplification and self-oscillation. The coincidence of bifurcation and self-oscillation thresholds reveals that the origin of coherent emission of the amplifier lies in the multiwave mixing of the noise components. Incorporation of the back action leads the system to exhibit hysteresis, dependent on parameters such as temperature and detuning from resonance. Our analysis also shows that the resonance condition itself changes in the presence of back action and this can be understood in terms of the change in plasma frequency of the junction. The potential of the double-pump amplifier for quantum-limited measurements and as a squeezer is also discussed.