Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

OptSp

Random errors in band-shift measurement of anomalous dispersion

B. V. Dobrolezh, M. N. Polyanskii, N. S. Ryazanov

Published Feb 1, 1981• 0 citations
OpenAlex

Related papers

Tunable pass band of anomalous dispersion photonic crystals

Jiangtao Liu, Xiao Wen-Bo, Jie‐Hui Huang +3 more

The influence of laser beam on the transmittance properties of anomalous dispersion photonic crystals (PCs) is investigated. Our calculations show that the pass band of anomalous dispersion PCs is tunable when altering the electron population in the atomic ground state of the anomalous dispersion material by the optical pumping method. With circularly polarized pump light, a huge Faraday rotation can be achieved under weak light intensity. Tunable pass band of anomalous dispersion PCs may lead to important technological applications in the optically controlled optical switch.

Acta Physica Sinica•Jan 1, 2010•1 citation

Frequency conversion in anomalous dispersion medium

Huaijin Ren, Ning An, Yuanlin Zheng +1 more

•Mar 1, 2014•0 citations

Transfer of information in an anomalous dispersion medium

Chao-Guang Huang, Yuan‐Zhong Zhang

Science in China. Series G, Physics, mechanics & astronomy/Science in China. Series G, Physics, Mechanics & Astronomy•Jul 15, 2003•0 citations

Low wavenumber Raman spectroscopy using atomic filters (Conference Presentation)

Xiaobo Xue, Corey T. Janisch, Yizhu Chen +2 more

Low-wavenumber Raman spectroscopy has long been demonstrated as a method of optical characterization in a variety of applications, such as thermal detection and semiconductor analysis. However, accessing low-wavenumber Raman shifts remains a challenge, usually requiring an expensive and complex multi-stage spectrographic system to measure several cm-1 Raman shifts. In this work, we demonstrate a method to measure low-wavenumber Raman shifts down to 1 cm-1 using atomic filters. By using a narrow-band Faraday anomalous dispersion optical filter to remove spontaneous emission noise from the laser cavity and a heated atomic cell as a notch filter to remove the excitation laser, the system is able to measure low Raman shifts (down to 1 cm-1). To demonstrate the capabilities, we measure the broadband Raman spectrum from a silica optical fiber with approximately 0.3 cm-1 resolution, detecting both Stokes and Anti-Stokes Raman shift as low as 0.7 cm-1.

Ultrafast Nonlinear Imaging and Spectroscopy•Nov 2, 2016•0 citations

Optical single-sideband (OSSB) Raman laser based on atomic filter for atom gravimeters

Yi Cong, Yang Chun Zhao, Wei Zhuang +3 more

Phase-modulator-generated Raman laser is widely used in atom gravimeters to simplify system and improve robustness. However, the induced additional sidebands (ASBs) lead to systematic errors in gravity measurement. This work presents a novel method to generate optical single-sideband (OSSB) Raman laser based on Faraday anomalous dispersion atomic filter (FADOF). The experimental result indicates that it can reduce the additional sidebands to lower than -50 dB, and the phase shift caused by ASBs is demonstrated to be effectively suppressed from 358.8 mrad to 2.2 mrad. Furthermore, this system has already applied on atom gravimeter to achieve primary gravity measurement. It shows that FADOF-based Raman laser is a new scheme for a compact atom absolute gravimeter.

•Dec 8, 2023•0 citations

Dispersion and Absorption Anomalies in Three-Level Systems

B. Hönerlage, J.‐Y. Bigot

De Gruyter eBooks•Dec 31, 1984•0 citations
The influence of laser beam on the transmittance properties of anomalous dispersion photonic crystals (PCs) is investigated. Our calculations show that the pass band of anomalous dispersion PCs is tunable when altering the electron population in the atomic ground state of the anomalous dispersion material by the optical pumping method. With circularly polarized pump light, a huge Faraday rotation can be achieved under weak light intensity. Tunable pass band of anomalous dispersion PCs may lead to important technological applications in the optically controlled optical switch.
Low-wavenumber Raman spectroscopy has long been demonstrated as a method of optical characterization in a variety of applications, such as thermal detection and semiconductor analysis. However, accessing low-wavenumber Raman shifts remains a challenge, usually requiring an expensive and complex multi-stage spectrographic system to measure several cm-1 Raman shifts. In this work, we demonstrate a method to measure low-wavenumber Raman shifts down to 1 cm-1 using atomic filters. By using a narrow-band Faraday anomalous dispersion optical filter to remove spontaneous emission noise from the laser cavity and a heated atomic cell as a notch filter to remove the excitation laser, the system is able to measure low Raman shifts (down to 1 cm-1). To demonstrate the capabilities, we measure the broadband Raman spectrum from a silica optical fiber with approximately 0.3 cm-1 resolution, detecting both Stokes and Anti-Stokes Raman shift as low as 0.7 cm-1.
Phase-modulator-generated Raman laser is widely used in atom gravimeters to simplify system and improve robustness. However, the induced additional sidebands (ASBs) lead to systematic errors in gravity measurement. This work presents a novel method to generate optical single-sideband (OSSB) Raman laser based on Faraday anomalous dispersion atomic filter (FADOF). The experimental result indicates that it can reduce the additional sidebands to lower than -50 dB, and the phase shift caused by ASBs is demonstrated to be effectively suppressed from 358.8 mrad to 2.2 mrad. Furthermore, this system has already applied on atom gravimeter to achieve primary gravity measurement. It shows that FADOF-based Raman laser is a new scheme for a compact atom absolute gravimeter.