Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

APS

Thermal activation and quantum tunneling in a superconducting persistent-current qubit

K. Segall, Terry P. Orlando, Donald S. Crankshaw, D. Nakada, Bhuwan Singh, Janice C. Lee, Lin Tian, Leonid S Levitov, Seth Lloyd, Sergio O. Valenzuela, Nina Marković, M. Tinkham

Published Mar 1, 2003• 0 citations
OpenAlex

Related papers

Decoherence of the Superconducting Persistent Current Qubit

Lin Tian, Leonid S Levitov, Caspar H. van der Wal +5 more

arXiv:cond-mat/9910062•Springer eBooks•Jan 1, 2000•33 citations

Energy Relaxation Time between Macroscopic Quantum Levels in a Superconducting Persistent-Current Qubit

D. Nakada, J. C. Lee, Yi Yu

Physical Review A•Jan 1, 2004•0 citations

Microwave-Induced Cooling of a Superconducting Persistent-Current Qubit

Sergio O. Valenzuela, William D. Oliver, David M. Berns +3 more

Bulletin of the American Physical Society•Mar 6, 2007•0 citations

Coherent Quasiclassical Dynamics of a Superconducting Persistent-Current Qubit

David M. Berns, William D. Oliver, Sergio O. Valenzuela +4 more

Bulletin of the American Physical Society•Mar 6, 2007•0 citations

Impact of time-ordered measurements of the two states in a niobium superconducting qubit structure

K. Segall, Donald S. Crankshaw, D. Nakada +7 more

Measurements of thermal activation are made in a superconducting, niobium persistent-current qubit structure, which has two stable classical states of equal and opposite circulating current. The magnetization signal is read out by ramping the bias current of a dc superconducting quantum interference device. This ramping causes time-ordered measurements of the two states, where measurement of one state occurs before the other. This time ordering results in effective measurement time, which can be used to probe the thermal activation rate between the two states. Fitting the magnetization signal as a function of temperature and ramp time allows one to estimate a quality factor of $3\ifmmode\times\else\texttimes\fi{}{10}^{5}$ for our devices, a value favorable for the observation of long quantum coherence times at lower temperatures.

arXiv:cond-mat/0302553•Physical review. B, Condensed matter•Jun 27, 2003•12 citations

Long coherence time in a superconducting persistent-current qubit

Jonas Bylander, Simon Gustavsson, Fumiki Yoshihara +4 more

Bulletin of the American Physical Society•Mar 18, 2010•0 citations
Measurements of thermal activation are made in a superconducting, niobium persistent-current qubit structure, which has two stable classical states of equal and opposite circulating current. The magnetization signal is read out by ramping the bias current of a dc superconducting quantum interference device. This ramping causes time-ordered measurements of the two states, where measurement of one state occurs before the other. This time ordering results in effective measurement time, which can be used to probe the thermal activation rate between the two states. Fitting the magnetization signal as a function of temperature and ramp time allows one to estimate a quality factor of $3\ifmmode\times\else\texttimes\fi{}{10}^{5}$ for our devices, a value favorable for the observation of long quantum coherence times at lower temperatures.