The paper theoretically and experimentally investigates the fundamental limitations imposed by spin (or atomic) quantum projection noise on the sensitivity of optical quantum sensors based on thermal atoms (this class of devices includes frequency standards, magnetometers, and gyroscopes using optical detection of electron paramagnetic resonance). The effect of increasing the rms amplitude of the projection noise in the magnetometric scheme under the influence of strong optical pumping is demonstrated, its explanation is proposed and experimentally tested - it is shown that in a wide range of pump intensities this effect is explained by the invariance of the projection noise integral power with respect to the magnetic resonance line width. An experimental study of the parameters of projection noise in a magnetometric quantum sensor was carried out, recommendations were given for optimizing the sensor parameters.
The paper theoretically and experimentally investigates the fundamental limitations imposed by spin (or atomic) quantum projection noise on the sensitivity of optical quantum sensors based on thermal atoms (this class of devices includes frequency standards, magnetometers, and gyroscopes using optical detection of electron paramagnetic resonance). The effect of increasing the rms amplitude of the projection noise in the magnetometric scheme under the influence of strong optical pumping is demonstrated, its explanation is proposed and experimentally tested - it is shown that in a wide range of pump intensities this effect is explained by the invariance of the projection noise integral power with respect to the magnetic resonance line width. An experimental study of the parameters of projection noise in a magnetometric quantum sensor was carried out, recommendations were given for optimizing the sensor parameters.
Abstract The principal limitations imposed by spin (or atomic) quantum projection noise on the sensitivity of optical quantum sensors on thermal atoms, which include frequency standards, magnetometers, and gyroscopes that use optical detection of electron paramagnetic resonance, have been theoretically and experimentally studied. The effect of increasing the rms amplitude of the projection noise in a magnetometric scheme under the influence of a strong optical pumping has been demonstrated. Its explanation has been proposed and experimentally confirmed: it has been shown that this effect is explained by the invariance of the integral power of projection noise in relation to the magnetic resonance linewidth in a wide range of pumping intensities An experimental study of the parameters of projection noise in a magnetometric quantum sensor has been conducted and recommendations for optimizing the sensor parameters have been given.
Quantum manipulation technology and photoelectric detection technology have jointly facilitated the rapid development of ultra-sensitive atomic spin magnetometers. To improve the output signal and sensitivity of the spin-exchange-relaxation-free (SERF) atomic spin magnetometer, the noises influencing on the output signal and the sensitivity were analyzed, and the corresponding noise suppression methods were presented. The magnetic field noises, including the residual magnetic field noise and the light shift noise, were reduced to approximately zero by employing the magnetic field compensation method and by adjusting the frequency of the pump beam, respectively. With respect to the operation temperature, the simulation results showed that the temperature of the potassium atomic spin magnetometer realizing the spin-exchange relaxation-free regime was 180 °C. Moreover, the fluctuation noises of the frequency and the power were suppressed by using the frequency and the power stable systems. The experimental power stability results showed that the light intensity stability was enhanced 10%. Contrast experiments on the sensitivity were carried out to demonstrate the validity of the suppression methods. Finally, a sensitivity of 13 fT/Hz(1/2) was successfully achieved by suppressing noises and optimizing parameters.
We study quantum enhancement of sensitivity using squeezed light in a multiparameter quantum sensor, the hybrid dc and rf optically pumped magnetometer (hOPM) [M. Lipka , Multiparameter quantum sensing and magnetic communication with a hybrid dc and rf optically pumped magnetometer, , 034054 (2024)]. Using a single spin ensemble, the hOPM acquires both the dc field strength (scalar magnetometry) and resonantly detects one quadrature of the ac magnetic field at a chosen frequency (rf magnetometry). In contrast to the Bell-Bloom scalar magnetometer [C. Troullinou , Squeezed-light enhancement and backaction evasion in a high sensitivity optically pumped magnetometer, , 193601 (2021)], the backaction evasion in the hOPM is incomplete, leading to a nontrivial interplay of the three quantum noise sources in this system: photon shot noise, spin projection noise, and measurement backaction noise. We observe these interactions using squeezed light as a tool to control the distribution of optical quantum noise between S 2 and S 3 polarization Stokes components, and the resulting effect on readout quantum noise and measurement backaction. These results demonstrate quantum-enhanced sensitivity in a continuously operating multiparameter sensor and reveal fundamental trade-offs between sensitivity, backaction, and bandwidth.
Present protocols for obtaining the ultimate magnetic sensitivity of optically pumped magnetometers (OPMs) utilizing alkali-metal ensembles rely on uncorrelated atoms in stretched states. A new approach for calculating the spin projection noise (SPN)-limited signal to noise ratio (SNR) and the magnetic sensitivity of OPMs is proposed. Our model is based solely on the mean-field density matrix dynamics and in contrast to previous models, it applies to both low and high field regimes, it takes into account the degree of spin polarization, the intra- and interhyperfine correlations, the decoherence processes, the atom-light coupling and the effects of the spin dynamics on the spin-noise spectra. Fine tuning of the probe frequency allow us to explore different hyperfine states and ground-state correlations. Especially in the spin-exchange-relaxation-free (SERF) regime, alongside the magnetic resonance narrowing and the increased number density, hallmarks of SERF magnetometers, we report on a new SERF feature; the reduction of spin-projection noise at the spin precession frequency as a consequence of strongly-correlated hyperfine spins that attenuate and redistribute SPN when properly probed.
We experimentally investigate the quantum noise mechanisms that limit continuously operating multiparameter quantum sensors. Using a hybrid rf-dc optically pumped magnetometer, we map the photon shot noise, spin projection noise, and measurement back-action noise over an order of magnitude in probe power and a factor of three in pump power while remaining quantum-noise-limited. We observe linear, quadratic, and cubic scaling of the respective total noise powers with probe photon flux, together with a quadratic dependence of back-action on pump photon flux, in quantitative agreement with a stochastic Bloch-equation model. At higher probe powers, additional probe-induced relaxation modifies the spin-noise spectrum while preserving the integrated noise scaling. Our results reveal fundamental, resource-dependent trade-offs unique to continuously monitored multiparameter sensors and establish experimentally the quantum limits governing their optimal operation.
(English) This thesis describes experiments that employ squeezed light to improve the performance of a sensitive optically-pumped magnetometer (OPM). The squeezed light source employs parametric amplification of vacuum fluctuations to produce squeezed vacuum and polarization-squeezed light tunable around the Rb D1 line. The OPM employs Bell-Bloom optical pumping of a high density vapor (with atom number density 10^{13}) and paramagnetic Faraday rotation, also on the Rb D1 line. The setup allows convenient switching from probing with laser light to probing with polarization-squeezed light, to study the use of the latter in atomic magnetometry. The magnetometer shows sub-pT/Hz^{1/2} sensitivity, limited by quantum noise; spin projection noise at low frequencies (<100Hz) and photon shot noise at high frequencies. Probing with polarization squeezed light suppresses the photon shot noise by 2dB, limited by the available squeezing and optical losses in passing through the vapor. This shot-noise suppression improves the high-frequency sensitivity and increases the measurement bandwidth, with no observed loss of sensitivity at any frequency. This result confirms experimentally the expected evasion of measurement back-action noise in the Bell-Bloom magnetometer. The thesis also develops a physical model to explain the observed spin dynamics of the Bell-Bloom magnetometer. The model describes the combined spin and optical polarization dynamics using Bloch equations with stochastic drive and detection noise terms. A perturbative approach and Fourier methods are then used to obtain analytic expressions for the magnetometer's frequency response, spin projection noise and photon shot noise. The role of measurement back-action emerges from a study of this model. As polarization squeezing reduces optical noise in the detected Stokes parameter, the accompanying ellipticity anti-squeezing is shunted into the unmeasured spin component. The thesis also reports a study of squeezed-light-enhanced magnetometry at a range of atomic densities, from 2.18 10^{12} atoms/cm3 to 1.13 10^{13} atoms/cm3 . Operating with fixed conditions of optical pumping, the signal amplitude, instrument noise spectrum and magnetic resonance width are measured as a function of atomic number density, for both laser- and squeezed-light probing. The equivalent magnetic noise spectra are then calculated. In the photon-shot-noise-limited portion of the spectrum, the squeezed light probing improves the magnetometer's sensitivity and measurement bandwidth for the full range of atomic density values. In particular, the laser-probed magnetometer shows a sensitivity optimum at n ~ 6 10 ^{12} atoms/cm3, and the squeezed-light-probed magnetometer surpasses this sensitivity. The thesis concludes with a discussion of the potential of stronger optical squeezing to enhance the instrument's sensitivity in different portions of the spectrum. Using the theory model we estimate the enhancement of the equivalent magnetic noise spectrum for 2 dB , 5.6 dB and perfect squeezing (zero noise in the detected polarization component) at the input to the atomic medium. (Català) Aqueta tesi descriu la millora d’un magnetòmetre de bombeig òptic (OPM) mitjançant l’ús d’estats de llum amb incertesa comprimida (squeezed states). S’usa amplificació paramètrica per a comprimir la incertesa de la font de llum. En concret, es comprimeix la incertesa de l’estat de buit quàntic, com també de la polarització òptica, amb la possibilitar d’ajustar la longitud d’ona al voltant de la transició atòmica D1 de 87Rb. L’OPM usa bombeig òptic Bell-Bloom de vapors d’alta densitat (amb densitats atòmiques properes a 1013) i rotació de Faraday, també al voltant de la transició atòmica D1 de 87Rb. L’aparell experimental permet canviar de mostreig amb llum coherent làser a mostreig amb llum de polarització comprimida, amb la finalitat d’avaluar el seu impacte en la sensitivitat del magnetòmetre. El magnetòmetre té una sensitivitat de sub-pT{ ?Hz , principalment limitada per soroll quàntic; soroll de projecció de spin a baixes freqüències (À 100 Hz) i soroll de quantització fotònica a altes freqüències. L’ús d’estats de llum amb polarització comprimida permet reduir el soroll fotònic en „ 2 dB, limitat per la compressió disponible i les pèrdues en travessar el vapor atòmic. La supressió del soroll fotònic augmenta l’amplada de banda del sistema amb l’avantatge de no perdre sensitivitat a cap banda de freqüència. Els resultats experimentals confirmen l’esperada supressió de retroalimentació de soroll en magnetòmetres de Bell-Bloom. La tesi també estudia el model teòric darrere les dinàmiques de spin en un magnetòmetre de tipus Bell-Bloom. El model descriu la combinació de les dinàmiques de spin i de la polarització òptica mitjançant equacions de Bloch forcades estocàsticament i amb termes de soroll de detecció. Es treballa en el límit pertorbatiu on mitjançant mètodes de Fourier s’obtenen expressions analítiques de la resposta en freqüència del magnetòmetre, dels sorolls de projecció de spin i del soroll de quantització fotònica. El rol de la retroalimentació de soroll també s’extrau d’aquest model. En concret, s’observa que la compressió en polarització redueix el soroll en els paràmetres de Stokes detectats, mentre els paràmetres de spin no mesurats experimenten una expansió de la seva incertesa (anti-squeezing). La tesi estudia magnetòmetres òptics de llum amb incertesa comprimida per a densitats entre 2.18 ˆ 1012 atoms{cm3 i 1.13 ˆ 1013 atoms{cm3. Es mesuren l’amplitud de senyal, l’espectre de soroll i l’amplada de la ressonància magnètica en funció de la densitat atòmica, per a un bombeig òptic constant i per a ambdós tipus de mostreig òptic (llum coherent i llum de polarització comprimida). A continuació, es calculen els espectres de soroll equivalents. En la part d’espectre on domina el soroll de quantització fotònica, s’observa que l’ús de llum de polarització comprimida millora la sensitivitat del magnetòmetre al llarg de tot el rang de densitats atòmics. En concret, la sensitivitat del magnetòmetre amb mostreig coherent és òptima per a n « 6ˆ1012 atoms{cm3 i es demostra una millora amb l’ús de mostreig amb llum comprimida. Es conclou amb una discussió sobre l’efecte de compressions més severes en la sensitivitat del magnetòmetre. Mitjançant el model teòric s’estima la millora en la sensitivitat per a compressions de 2 dB, 5.6 dB i “compressió perfecta” a l’entrada del medi atòmic