Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Softwaretechnik-Trends

Properties of Nb Thin Films and their Application for Diffusion-Cooled Hot-Electron Bolometer

Michael Frommberger, François Mattiocco, Philippe Sabon, Matthias Schicke, Karl-Friedrich Schuster, Olivier Laborde

Published May 1, 2000• 4 citations
OpenAlex

Abstract

The performance of hot electron bolometer mixer devices made out of superconducting thin films critically depends on film quality. We discuss various deposition conditions for Nb films and present their properties for a wide thickness range. The obtained film parameters allow to predict the characteristics of our actual devices. We also shortly present a new fabrication process for Nb diffusion cooled hot electron bolometer mixers. I.

Related papers

Fabrication and characterization of hot-electron bolometers for THz applications

Michael Frommberger, Philippe Sabon, Matthias Schicke +2 more

Superconducting properties of Nb and NbN thin films for application in diffusion and phonon cooled Hot-Electron Bolometers have been systematically investigated. The materials were sputtered on fused quartz substrates in a wide thickness range. DC-measurements of the Nb films allow us to predict the intermediate frequency bandwidth of a hot-electron bolometer mixer device for a given design. To improve the characteristics of the NbN thin films, we used a 15 nm MgO seed layer.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•6 citations

Ultra-thin film NbN depositions for HEB heterodyne mixer on Si-substrates

Sascha Krause, Vincent Desmaris, Alexey Pavolotsky +3 more

The key of improving hot-electron bolometer (HEB) mixer performance lies inevitably in the quality of ultra-thin NbN films itself. This work presents a thorough investigation of crucial process parameters of NbN films deposited by means of reactive DC-sputtering on Si-substrates at elevated temperatures up to 750°C.The polycrystalline NbN films with thickness of 4 to 10nm were characterized by DC resistivity measurements, ellipsometry and high resolution transmission electron microscopy (HRTEM) in order to confirm thickness and film structure. Since the macroscopic properties such as critical temperature, thickness as well as the transition width to the superconducting state are directly linked to HEB mixer noise temperature and IF bandwidth, a set of experiments were conducted to enhance aforementioned properties. We considered deposition temperature, RF biasing, nitrogen and argon partial and total pressure during deposition as major process variable parameters. Careful optimization of the deposition conditions allowed setting up a process resulting in high-quality NbN ultra-thin films with thickness of 5.5nm exhibiting Tc of 10.5K. Moreover, the transition width could be kept as low as 1.4K. The produced films were stored at ambient conditions and re-characterized over a period of 4 month without measurable degradation.

•Jan 1, 2013•0 citations

Study of the superconductor-normal metal interface in hot-electron bolometer mixers

Ю.Д. Третьяков, Matvey I. Finkel, P. Larionov +5 more

During the last few years significant progress has been made in the field of hot-electron bolometer (HEB) mixers. It has been possible to combine a low noise temperature and high stability of phonon-cooled HEBs with an ultrawide gain bandwidth of the diffusion-cooled HEBs in a single device and thus create HEB mixers which offer a noise temperature of 5hν/kB across a 7-GHz band. The essential ingredient of this success is the in situ fabrication technology, where the deposition of the gold contacts follows the deposition of the superconducting film without vacuum breaking. Despite the evident technological breakthrough, the details of certain physical processes occurring both at the superconductor-normal metal (SN) interface and in the superconducting bridge are not completely understood in terms of their influence on the mixer performance. In particular, it is still unclear to what extent the properties of the SN interface are affected by the deposition temperatures of the superconductor and the normal metal, and also by the time interval elapsed between the deposition processes. We will gain some insight into the matter by studying the behaviour of the superconducting transition as a function of the deposition temperatures and time delay. A better understanding of this issue will allow us to move forward the HEB mixer technology towards new applications.

•Jan 1, 2012•0 citations

NbN FILM DEVELOPMENT FOR PHONON-COOLED HEB DEVICES

Eyal Gerecht, Ashok K. Bhupathiraju, Erich N. Grossman +4 more

Superconducting Hot-electron Bolometric (HE.B) mixers employing thin films ofNbN have become the devices of choice for heterodyne detection at tera,hertz frequen- cies. HEB mixers are inherently insensitive to the bandgap frequency of the superconducting material used in the device, in contrast to SIS mixers,. We have developed a fabrication pro- cess for thin NbN films at the National Institute of Standards and Technology in Boulder, CO. A two-fold approach can be taken. The first is to maximize the critical temperature of the superconducting device by growing thicker films at the expense of IF bandwidth, whereas the second approach focuses on maximizing the IF bandwidth at the expense of the critical tem- perature. So far, we have developed a film-deposition process utilizing our DC reactive mag- netron sputtering chamber. By current-biasing the RF plasma in a mixture of Ar and N2, while using a Nb target, we can control the film stoichiometry and produce films with thicknesses of 5 nm. The films are deposited on MgO substrates that are heated to about 800 °C during depo- sition. A typical critical temperature (TO is about 10 K and the transition width is very small (0.5 K). The films are evaluated by measuring their superconducting characteristics as well as their thickness and surface roughness by means of AFM analysis. Phonon-cooled HEB devices are fabricated from the films to study their performance as HEB mixers. The device fabrication process at UMass/Amherst involves lift-off lithography of the antenna (gold), and Reactive ion etching (R1E) or wet etching of the NbN. The I-V char- acteristics and noise temperatures of the devices were measured in order to determine their quality for PHEB applications.

•Mar 1, 2002•1 citation

Large Bandwidth of NbN Phonon-Cooled Hot-Electron Bolometer Mixers

Serguei Cherednichenko, Pavel A. Yagoubov, K. Ilin +2 more

The bandwidth of NbN phonon-cooled hot electron bolometer mixers has been systematically investigated with respect to the film thickness and film quality variation. The films, 2.5 to 10 nm thick, were fabricated on sapphire substrates using DC reactive magnetron sputtering. All devices consisted of several parallel strips, each 1 μ wide and 2 μ long, placed between Ti-Au contact pads. To measure the gain bandwidth we used two identical BWOs operating in the 120-140 GHz frequency range, one functioning as a local oscillator and the other as a signal source. The majority of the measurements were made at an ambient temperature of 4.2 K with optimal LO and DC bias. The maximum 3 dB bandwidth (about 4 GHz) was achieved for the devices made of films which were 2.5-3.5 nm thick, had a high critical temperature, and high critical current density. A theoretical analysis of bandwidth for these mixers based on the two-temperature model gives a good description of the experimental results if one assumes that the electron temperature is equal to the critical temperature.

European Microwave Conference (EuMC)•Sep 1, 1997•27 citations

Fabrication and Receiver Measurements of a Diffusion-cooled Hot-electron Bolometer at 800 GHz

J. Stodolka, Kristof J. P. Jacobs

We present a fabrication process for diffusion-cooled niobium hot-electron bolometers using a self-aligned process with gold as an initial protection layer and aluminum as an etch mask that is removed by a wet etch. This process proves to be reproducible and has a yield of ~70 % per batch. Great care has been taken to avoid processing temperatures above 120 °C to minimize degradation of the Nb film. We have performed heterodyne measurements of an HEB in a fixed tuned waveguide mixer at 804 GHz and at an IF-range from 1-2 GHz. The approximate dimensions of the bridge are 240 x 200 x 14 nm3. The Niobium bridge has a critical temperature of 6.0 K and a normal state resistance of 16.5 Ω. A standard Y-factor measurement leads to a minimum noise temperature of 1200 K at 1 GHz IF. The coupled LO-power is estimated by the isothermal method to be 21 nW. Introduction Superconducting Hot-Electron-Bolometers (HEB) utilizing thin superconducting films have become established as sensitive mixers in the THz region. The thermal response time τ can be very small if the superconductor is thin enough that only the electron gas is heated and the cooling is fast enough. The bolometers described in this paper are cooled by out-diffusion of the hot electrons in normal conducting heat sinks (diffusion-cooled HEB) rather than interactions with phonons of the lattice (phononcooled HEB) [1]. To meet the requirements for astronomical applications such as SOFIA, thermal response times down to several picoseconds are needed to get intermediate frequencies up to 10 GHz. Because of τ ~ L [1] the dimensions of the bolometer bridge have to be very small. We have fabricated diffusion-cooled HEBs with short (L<300 nm) and narrow (<200 nm) bridges consisting of thin (10-14 nm) Niobium (Nb) on z-cut quartz substrates. The normal conducting heat sinks consist of 70 nm Gold (Au). In the following paragraph 1 e-mail: stodolka@ph1.uni-koeln.de we discuss problems and merits of several approaches for the fabrication of diffusioncooled HEBs. Device Fabrication Aside from a good reproducibility, the essential requirement for the fabrication of a diffusion-cooled HEB is a good transparency of the interface between the heat sinks and the material of the bolometer bridge. A thermal resistance results in a slower out-diffusion of the hot electrons and thus increases the effective bridge length and thermal response time. Defining the bolometer bridge by lift-off with subsequent deposition of the heat sinks (Fig. 1) [2] has the major disadvantage of high requirements for the overlap accuracy of the Electron-Beam-Lithography (EBL) system to position the heat sinks on the contact areas of the bridge. A solution is offered by the self-aligned process (Fig. 2). Here, the substrate is covered with a blanket layer of Nb. The heat sinks and a metal strip of the width of the bolometer bridge are deposited in succession. The bridge is now etched out of the blanket layer by using reactive ion etching (RIE) where the heat sinks and the metal strip serve as etch masks: the spacing between the heat sinks determines the bridge length while the metal strip defines the width. The overlap between Nb and Au heat sinks is large. Fig. 1: Outline of HEB fabrication by lift off (top view) a) Bolometer bridge defined by liftoff. b) Deposition of the heat sinks. The contact area (shaded) to the heat sinks is small. bolometer bridge

•Dec 1, 2001•2 citations
The performance of hot electron bolometer mixer devices made out of superconducting thin films critically depends on film quality. We discuss various deposition conditions for Nb films and present their properties for a wide thickness range. The obtained film parameters allow to predict the characteristics of our actual devices. We also shortly present a new fabrication process for Nb diffusion cooled hot electron bolometer mixers. I.
The key of improving hot-electron bolometer (HEB) mixer performance lies inevitably in the quality of ultra-thin NbN films itself. This work presents a thorough investigation of crucial process parameters of NbN films deposited by means of reactive DC-sputtering on Si-substrates at elevated temperatures up to 750°C.The polycrystalline NbN films with thickness of 4 to 10nm were characterized by DC resistivity measurements, ellipsometry and high resolution transmission electron microscopy (HRTEM) in order to confirm thickness and film structure. Since the macroscopic properties such as critical temperature, thickness as well as the transition width to the superconducting state are directly linked to HEB mixer noise temperature and IF bandwidth, a set of experiments were conducted to enhance aforementioned properties. We considered deposition temperature, RF biasing, nitrogen and argon partial and total pressure during deposition as major process variable parameters. Careful optimization of the deposition conditions allowed setting up a process resulting in high-quality NbN ultra-thin films with thickness of 5.5nm exhibiting Tc of 10.5K. Moreover, the transition width could be kept as low as 1.4K. The produced films were stored at ambient conditions and re-characterized over a period of 4 month without measurable degradation.
During the last few years significant progress has been made in the field of hot-electron bolometer (HEB) mixers. It has been possible to combine a low noise temperature and high stability of phonon-cooled HEBs with an ultrawide gain bandwidth of the diffusion-cooled HEBs in a single device and thus create HEB mixers which offer a noise temperature of 5hν/kB across a 7-GHz band. The essential ingredient of this success is the in situ fabrication technology, where the deposition of the gold contacts follows the deposition of the superconducting film without vacuum breaking. Despite the evident technological breakthrough, the details of certain physical processes occurring both at the superconductor-normal metal (SN) interface and in the superconducting bridge are not completely understood in terms of their influence on the mixer performance. In particular, it is still unclear to what extent the properties of the SN interface are affected by the deposition temperatures of the superconductor and the normal metal, and also by the time interval elapsed between the deposition processes. We will gain some insight into the matter by studying the behaviour of the superconducting transition as a function of the deposition temperatures and time delay. A better understanding of this issue will allow us to move forward the HEB mixer technology towards new applications.
Superconducting Hot-electron Bolometric (HE.B) mixers employing thin films ofNbN have become the devices of choice for heterodyne detection at tera,hertz frequen- cies. HEB mixers are inherently insensitive to the bandgap frequency of the superconducting material used in the device, in contrast to SIS mixers,. We have developed a fabrication pro- cess for thin NbN films at the National Institute of Standards and Technology in Boulder, CO. A two-fold approach can be taken. The first is to maximize the critical temperature of the superconducting device by growing thicker films at the expense of IF bandwidth, whereas the second approach focuses on maximizing the IF bandwidth at the expense of the critical tem- perature. So far, we have developed a film-deposition process utilizing our DC reactive mag- netron sputtering chamber. By current-biasing the RF plasma in a mixture of Ar and N2, while using a Nb target, we can control the film stoichiometry and produce films with thicknesses of 5 nm. The films are deposited on MgO substrates that are heated to about 800 °C during depo- sition. A typical critical temperature (TO is about 10 K and the transition width is very small (0.5 K). The films are evaluated by measuring their superconducting characteristics as well as their thickness and surface roughness by means of AFM analysis. Phonon-cooled HEB devices are fabricated from the films to study their performance as HEB mixers. The device fabrication process at UMass/Amherst involves lift-off lithography of the antenna (gold), and Reactive ion etching (R1E) or wet etching of the NbN. The I-V char- acteristics and noise temperatures of the devices were measured in order to determine their quality for PHEB applications.
The bandwidth of NbN phonon-cooled hot electron bolometer mixers has been systematically investigated with respect to the film thickness and film quality variation. The films, 2.5 to 10 nm thick, were fabricated on sapphire substrates using DC reactive magnetron sputtering. All devices consisted of several parallel strips, each 1 μ wide and 2 μ long, placed between Ti-Au contact pads. To measure the gain bandwidth we used two identical BWOs operating in the 120-140 GHz frequency range, one functioning as a local oscillator and the other as a signal source. The majority of the measurements were made at an ambient temperature of 4.2 K with optimal LO and DC bias. The maximum 3 dB bandwidth (about 4 GHz) was achieved for the devices made of films which were 2.5-3.5 nm thick, had a high critical temperature, and high critical current density. A theoretical analysis of bandwidth for these mixers based on the two-temperature model gives a good description of the experimental results if one assumes that the electron temperature is equal to the critical temperature.
We present a fabrication process for diffusion-cooled niobium hot-electron bolometers using a self-aligned process with gold as an initial protection layer and aluminum as an etch mask that is removed by a wet etch. This process proves to be reproducible and has a yield of ~70 % per batch. Great care has been taken to avoid processing temperatures above 120 °C to minimize degradation of the Nb film. We have performed heterodyne measurements of an HEB in a fixed tuned waveguide mixer at 804 GHz and at an IF-range from 1-2 GHz. The approximate dimensions of the bridge are 240 x 200 x 14 nm3. The Niobium bridge has a critical temperature of 6.0 K and a normal state resistance of 16.5 Ω. A standard Y-factor measurement leads to a minimum noise temperature of 1200 K at 1 GHz IF. The coupled LO-power is estimated by the isothermal method to be 21 nW. Introduction Superconducting Hot-Electron-Bolometers (HEB) utilizing thin superconducting films have become established as sensitive mixers in the THz region. The thermal response time τ can be very small if the superconductor is thin enough that only the electron gas is heated and the cooling is fast enough. The bolometers described in this paper are cooled by out-diffusion of the hot electrons in normal conducting heat sinks (diffusion-cooled HEB) rather than interactions with phonons of the lattice (phononcooled HEB) [1]. To meet the requirements for astronomical applications such as SOFIA, thermal response times down to several picoseconds are needed to get intermediate frequencies up to 10 GHz. Because of τ ~ L [1] the dimensions of the bolometer bridge have to be very small. We have fabricated diffusion-cooled HEBs with short (L<300 nm) and narrow (<200 nm) bridges consisting of thin (10-14 nm) Niobium (Nb) on z-cut quartz substrates. The normal conducting heat sinks consist of 70 nm Gold (Au). In the following paragraph 1 e-mail: stodolka@ph1.uni-koeln.de we discuss problems and merits of several approaches for the fabrication of diffusioncooled HEBs. Device Fabrication Aside from a good reproducibility, the essential requirement for the fabrication of a diffusion-cooled HEB is a good transparency of the interface between the heat sinks and the material of the bolometer bridge. A thermal resistance results in a slower out-diffusion of the hot electrons and thus increases the effective bridge length and thermal response time. Defining the bolometer bridge by lift-off with subsequent deposition of the heat sinks (Fig. 1) [2] has the major disadvantage of high requirements for the overlap accuracy of the Electron-Beam-Lithography (EBL) system to position the heat sinks on the contact areas of the bridge. A solution is offered by the self-aligned process (Fig. 2). Here, the substrate is covered with a blanket layer of Nb. The heat sinks and a metal strip of the width of the bolometer bridge are deposited in succession. The bridge is now etched out of the blanket layer by using reactive ion etching (RIE) where the heat sinks and the metal strip serve as etch masks: the spacing between the heat sinks determines the bridge length while the metal strip defines the width. The overlap between Nb and Au heat sinks is large. Fig. 1: Outline of HEB fabrication by lift off (top view) a) Bolometer bridge defined by liftoff. b) Deposition of the heat sinks. The contact area (shaded) to the heat sinks is small. bolometer bridge