Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Adaptive Resonance Imaging and All-Optical Atom Interferometry

M. Marable

Published Jan 1, 1995• 1 citation
OpenAlex

Related papers

Adaptive atom-optics in atom interferometry

M. Marable, T. A. Savard, John E. Thomas

Optics Communications•Feb 1, 1997•1 citation

Atom interferometry in a marginally stable optical resonator

Isabelle Riou, N. Mielec, G. Lefèvre +6 more

•Jan 5, 2017•0 citations

Direct calibration of laser intensity via Ramsey interferometry for cold atom imaging

Emine Altuntaş, Ian B. Spielman

A majority of ultracold atom experiments utilize resonant absorption imaging techniques to obtain the atomic density. To make well-controlled quantitative measurements, the optical intensity of the probe beam must be precisely calibrated in units of the atomic saturation intensity I sat . In quantum gas experiments, the atomic sample is enclosed in an ultra-high vacuum system that introduces loss and limits optical access; this precludes a direct determination of the intensity. Here, we use quantum coherence to create a robust technique for measuring the probe beam intensity in units of I sat via Ramsey interferometry. Our technique characterizes the ac Stark shift of the atomic levels due to an off-resonant probe beam. Furthermore, this technique gives access to the spatial variation of the probe intensity at the location of the atomic cloud. By directly measuring the probe intensity just before the imaging sensor our method in addition yields a direct calibration of imaging system losses as well as the quantum efficiency of the sensor.

arXiv:2304.00656•Optics Express•May 4, 2023•4 citations

Atom interferometry and quantum optics

Herman C. W. Beijerinck, K. A. H. van Leeuwen

•Jan 1, 2007•0 citations

Quantum-enhanced Atom Interferometry

Robin Corgier, Luca Pezzè, Franck Pereira dos Santos

•Oct 25, 2023•0 citations

Application of Fourier-Fresnel Imaging to Neutral - Atom Interferometry

John F. Clauser

Abstract : This note provides a brief summary of the use of Fourier-Fresnel imaging to neutral atom interferometry. In applications of neutral-atom interferometry not requiring the interferometer to have an open (multiply connected) topology, the use of this imaging has significant advantages, notably ease of alignment, significantly increased through-put flux, ability to work with very short wavelength (and/or high velocity atoms). The results are primarily interesting in that they span the boundary between trapezoidal moire fringes and sinusoidal wave-interference fringes. Their limited applicability, perhaps accounts for the relative obscurity of many of the results to typical curricula of modern-day optics. The emphasis in this note is thus to put existing results (along with some additions that are needed for clarity) in a form suitable for use by techniques available for neutral-atom interferometry.

Unknow•Oct 3, 1990•0 citations
A majority of ultracold atom experiments utilize resonant absorption imaging techniques to obtain the atomic density. To make well-controlled quantitative measurements, the optical intensity of the probe beam must be precisely calibrated in units of the atomic saturation intensity I sat . In quantum gas experiments, the atomic sample is enclosed in an ultra-high vacuum system that introduces loss and limits optical access; this precludes a direct determination of the intensity. Here, we use quantum coherence to create a robust technique for measuring the probe beam intensity in units of I sat via Ramsey interferometry. Our technique characterizes the ac Stark shift of the atomic levels due to an off-resonant probe beam. Furthermore, this technique gives access to the spatial variation of the probe intensity at the location of the atomic cloud. By directly measuring the probe intensity just before the imaging sensor our method in addition yields a direct calibration of imaging system losses as well as the quantum efficiency of the sensor.
Abstract : This note provides a brief summary of the use of Fourier-Fresnel imaging to neutral atom interferometry. In applications of neutral-atom interferometry not requiring the interferometer to have an open (multiply connected) topology, the use of this imaging has significant advantages, notably ease of alignment, significantly increased through-put flux, ability to work with very short wavelength (and/or high velocity atoms). The results are primarily interesting in that they span the boundary between trapezoidal moire fringes and sinusoidal wave-interference fringes. Their limited applicability, perhaps accounts for the relative obscurity of many of the results to typical curricula of modern-day optics. The emphasis in this note is thus to put existing results (along with some additions that are needed for clarity) in a form suitable for use by techniques available for neutral-atom interferometry.