Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

Time-domain analysis on the pulsed squeezed vacuum detected with picosecond pulses

Yoshitaka Taguchi, Yasuyuki Ozeki

Published Mar 31, 2020• 15 citations
Publisher

Abstract

The pulsed squeezed state of light is expected to enhance the sensitivity of optical measurements using optical pulses. To achieve a high squeezing level, it is crucial to explore its limiting factors. In this study, we analyze the pulsed squeezed vacuum detected with picosecond pulses to explore two critical factors that limit the achievable squeezing level. First, we investigate the effect of the frequency chirp of local oscillator (LO) pulses and show that there exists an upper bound of the chirp parameter for a given squeezing level. Next, we analyze the effect of temporal matching between the LO pulse and the squeezed vacuum and point out the importance of temporal broadening in nonlinear optical crystals for squeezing.

DOI
10.1364/josab.389039

Related papers

Time-Domain Analysis on the Impacts of Chirp and Walk-Off in Picosecond Pulsed Squeezing

Yoshitaka Taguchi, Yasuyuki Ozeki

We investigate the relation between the squeezing level, chirp parameter of pulses, and the effect of group velocity difference in nonlinear crystals through time-domain analysis, which realizes straightforward evaluation of picosecond pulsed squeezing.

Conference on Lasers and Electro-Optics•Jan 1, 2020•0 citations

Temporal phase characterization of picosecond pulsed squeezed vacuum

Zicong Xu, Sho Nitanai, Yasuyuki Ozeki

We propose a method to measure the temporal phase of ultrashort pulsed squeezed vacuum. We verified that the temporal chirp has limited influence on pulsed squeezing level.

Conference on Lasers and Electro-Optics•Jan 1, 2024•0 citations

Bright Pulsed Squeezed Light for Quantum-Enhanced Precision Microscopy

Alex Terrasson, Lars Madsen, Joel Grim +1 more

Squeezed states of light enable enhanced measurement precision by reducing noise below the standard quantum limit. A key application of squeezed light is nonlinear microscopy, where state-of-the-art performance is limited by photodamage and quantum-limited noise. Such microscopes require bright, pulsed light for optimal operation, yet generating and detecting bright pulsed squeezing at high levels remains challenging. In this work, we present an efficient technique to generate high levels of bright picosecond pulsed squeezed light using a $χ^2$ optical parametric amplification process in a waveguide. We measure $-3.2~\mathrm{dB}$ of bright squeezing with optical power compatible with nonlinear microscopy, as well as $-3.6~\mathrm{dB}$ of vacuum squeezing. Corrected for losses, these squeezing levels correspond to $-15.4^{+2.7}_{-8.7}~\mathrm{dB}$ of squeezing generated in the waveguide. The measured level of bright amplitude pulsed squeezing is to our knowledge the highest reported to date, and will contribute to the broader adoption of quantum-enhanced nonlinear microscopy in biological studies.

quant-pharXiv:2601.15565•Jan 23, 2026•1 citation

Temporal Characteristics of Pulsed Squeezing in a Nonlinear Optical Waveguide

Yujiro Eto, Akane Koshio, Akito Ohshiro +3 more

We experimentally investigate the temporal characteristics of picosecond squeezed pulses generated via an optical parametric amplification in a periodically poled MgO:LiNbO3 waveguide. The noise variances for the various time delays between the squeezed pulse and a local oscillator are measured using a balanced homodyne detector. The measured delay dependence is asymmetric, and this asymmetry indicates that the phase chirping of the squeezed pulse is different from that of the local oscillator pulse. We show that the observed squeezing can be improved by using the pulse shaping of the local oscillator.

Japanese Journal of Applied Physics•Mar 8, 2013•2 citations

Efficient homodyne measurement of picosecond squeezed pulses with pulse shaping technique

Yujiro Eto, Akane Koshio, Akito Ohshiro +4 more

We report on the detection of picosecond pulsed squeezed light generated by an optical parametric amplification in a periodically poled MgO:LiNbO(3) waveguide. By using a temporally shaped local oscillator in a balanced homodyne detection, we obverved the squeezing of -5.0 dB below the shot noise level. The squeezing level at the exit of the waveguide was estimated to be -9.7±0.8 dB.

Optics Letters•Nov 28, 2011•31 citations

Pulsed squeezed-light measurement: a new technique

Orhan Aytür, Prem Kumar

A transient noise measurement scheme is described to observe pulsed squeezing generated by means of parametric downconversion of a Q-switched laser. In the usual implementation of balanced-homodyne detection, the vacuumstate noise level is determined by the average local oscillator power. However, if the local oscillator is derived from a pulsed laser, as is the case in our experiments, the associated peak power can easily saturate the detectors along with the subsequent electronics. To overcome this limitation we have implemented a hybrid frequency-time-domain measurement scheme in which the vacuum-state noise level is determined by the peak, instead of the average, local oscillator power, thus avoiding the saturation problem.

Optics Letters•Apr 1, 1990•22 citations
The pulsed squeezed state of light is expected to enhance the sensitivity of optical measurements using optical pulses. To achieve a high squeezing level, it is crucial to explore its limiting factors. In this study, we analyze the pulsed squeezed vacuum detected with picosecond pulses to explore two critical factors that limit the achievable squeezing level. First, we investigate the effect of the frequency chirp of local oscillator (LO) pulses and show that there exists an upper bound of the chirp parameter for a given squeezing level. Next, we analyze the effect of temporal matching between the LO pulse and the squeezed vacuum and point out the importance of temporal broadening in nonlinear optical crystals for squeezing.
Squeezed states of light enable enhanced measurement precision by reducing noise below the standard quantum limit. A key application of squeezed light is nonlinear microscopy, where state-of-the-art performance is limited by photodamage and quantum-limited noise. Such microscopes require bright, pulsed light for optimal operation, yet generating and detecting bright pulsed squeezing at high levels remains challenging. In this work, we present an efficient technique to generate high levels of bright picosecond pulsed squeezed light using a χ2χ^2χ2 optical parametric amplification process in a waveguide. We measure −3.2 dB-3.2~\mathrm{dB}−3.2 dB of bright squeezing with optical power compatible with nonlinear microscopy, as well as −3.6 dB-3.6~\mathrm{dB}−3.6 dB of vacuum squeezing. Corrected for losses, these squeezing levels correspond to −15.4−8.7+2.7 dB-15.4^{+2.7}_{-8.7}~\mathrm{dB}−15.4−8.7+2.7​ dB of squeezing generated in the waveguide. The measured level of bright amplitude pulsed squeezing is to our knowledge the highest reported to date, and will contribute to the broader adoption of quantum-enhanced nonlinear microscopy in biological studies.
We experimentally investigate the temporal characteristics of picosecond squeezed pulses generated via an optical parametric amplification in a periodically poled MgO:LiNbO3 waveguide. The noise variances for the various time delays between the squeezed pulse and a local oscillator are measured using a balanced homodyne detector. The measured delay dependence is asymmetric, and this asymmetry indicates that the phase chirping of the squeezed pulse is different from that of the local oscillator pulse. We show that the observed squeezing can be improved by using the pulse shaping of the local oscillator.
A transient noise measurement scheme is described to observe pulsed squeezing generated by means of parametric downconversion of a Q-switched laser. In the usual implementation of balanced-homodyne detection, the vacuumstate noise level is determined by the average local oscillator power. However, if the local oscillator is derived from a pulsed laser, as is the case in our experiments, the associated peak power can easily saturate the detectors along with the subsequent electronics. To overcome this limitation we have implemented a hybrid frequency-time-domain measurement scheme in which the vacuum-state noise level is determined by the peak, instead of the average, local oscillator power, thus avoiding the saturation problem.