Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Hybrid 3He and alkali magnetometry techniques for fundamental physics experiments

C. Abel

Published Mar 6, 2020• 0 citations
OpenAlex

Abstract

Since the 1950s, experiments searching for the neutron electric dipole moment have increased in sensitivity by six orders of magnitude. Yet, the current experimental sensitivity lies well above that predicted from standard model calculations. Corrections from physics beyond the standard model increase the predicted size of the nEDM, resulting in the nextgeneration of experiments hovering tantalisingly close to the detection sensitivity, to either verify or quash standard model extensions. One such experiment, n2EDM, currently in the commissioning stage at the Paul Scherrer Institute in Switzerland, hopes to measure the nEDM with a sensitivity improvement over its predecessor. This thesis details the design, measurement and analysis of hybrid 3He/alkali magnetometers for both accurate and precise magnetic field readings at low and zero fields, crucial for the development of ever-more sensitive fundamental physics searches. The work exploits the precise nature of alkali (87Rb and 133Cs) magnetometry techniques to measure the simultaneous Larmor precession of polarised 3He, avoiding light shifts commonly associated with optically pumped magnetometers. The first part of this work demonstrates the use of a hybrid 3He/87Rb magnetometer for the minimisation of remnant fields in a magnetically shielded environment, resulting in absolute low-field readings below 5 pT. Furthermore, the hybrid magnetometer was shown to be applicable for the reduction of gradient fields by optimising the effective 3He T2 time. This new technique represents a convenient and consistent way to achieve a near-zero magnetic field environment for precision experiments. Second, a new measurement technique was demonstrated using a hybrid 3He/133Cs magnetometer in a 1 µT field, placing experimental limits on the coupling of axion-like dark matter to nucleons. The measurement excluded axion coupling strength to 2:5 x 10-1 GeV-1 for axion masses between 10-20 to 10-17 eV at the 95% level. With the resulting exclusion region weaker than previous measurements, possible improvements to the apparatus should drive the development of a low-cost long-term axion interaction search.

Related papers

Searching for Axion Dark Matter via Superconductor-Spin Hybrid Magnetometers

Runqi Kang, Jian Zhang, Liangliang Rong +1 more

Axions are a compelling dark matter candidate suggested by theories beyond the Standard Model. The predicted axion-electron coupling and the resulting pseudomagnetic field allow for laboratory axion searches. Here we report an experimental axion search via a superconductor-spin hybrid magnetometer. A state-of-the-art broadband magnetometer with a sensitivity of sub-100 aT/Hz$^{1/2}$ at tens of kHz has been realized by coupling a ferrite spin sensor to a readout system based on a superconducting quantum interference device. The most stringent terrestrial constraints on the axion-electron coupling have been established in the frequency range 5$\sim$60 kHz. In the future, an improvement on the constraints of more than 4 orders of magnitude is foreseeable through arrays of superconductor-spin hybrid magnetometers with optimized designs. This work demonstrates the potential of superconductor-spin hybrid magnetometers in high-precision magnetic field sensing and the study of fundamental physics.

physics.ins-detCross-listedarXiv:2610.27764•Oct 21, 2026

Ultra-cold atomic magnetometry: realisation and test of a ⁸⁷Rb BEC for high-sensitivity magnetic field measurements

Michela Venturelli

The development of an experimental apparatus to produce Bose-Einstein condensates (BECs) of ⁸⁷Rb atoms and their application to magnetometry are discussed. Optical detection of atomic Larmor precession is a widely explored method for high-sensitivity measurements of magnetic fields. In this context, short laser/atom interaction time, atomic thermal diffusion and decoherence effects are among the main limitations. In this thesis, we overcome such problems by using spin-polarised ⁸⁷Rb ultra-cold atoms as the sensing element. After the atoms are polarised, a resonant pulse of radio-frequency excites Larmor precession, which is sensitive to external magnetic fields. By measuring the perturbations of the radio-frequency induced spin precession, information on the magnetic fields of interest. This is achieved by monitoring the polarisation plane’s rotation of a linearly polarised resonant laser probe. In the first part of this thesis, the building and optimisation of a laser-cooling set up to obtain a BEC in a hybrid trap is reported. In order to achieve the Phase Space Density (PSD) required for BEC, several different stages of trapping and cooling are necessary. Each phase has been implemented and optimised. The first step consists in the magneto-optical trap (MOT). Here a velocity dependent damping force and a spatially dependent confining force give the largest changes in PSD. Then atoms are loaded into a hybrid trap obtained by overlapping a quadrupole magnetic potential and a far detuned optical crossed dipole trap. The final stage for the condensation consists of forced evaporative cooling, both via magnetic and optical evaporation. In the second part of the thesis, a general overview of the principles of optical atomic magnetometry is provided and the advantages of using ultra-cold atoms with respect to conventional thermal vapours are discussed. The implementation, operation and a preliminary characterisation of the ultra-cold atom magnetometer are described along with the preliminary results collected. Finally, a plan for future improvements of its sensitivity is presented.

•Sep 28, 2018•0 citations

Prospects for spin squeezing in nuclear magnetic resonance dark matter searches

Eric Boyers

Direct detection of dark matter remains an important outstanding problem since abundant astrophysical evidence points towards its existence, but no experiment has succeeded in detecting it. Axions and axion-like-particles are some of the most compelling candidates for dark matter given their appearance in many theories of physics beyond the Standard Model and their relatively unexplored parameter space compared to other candidates. Recently, the Cosmic Axion Spin Precession Experiment-Electric (CASPEr-e) has used nuclear magnetic resonance (NMR) to search for effective magnetic fields created by axionic dark matter. By decreasing technical noise sources, CASPEr-e is projected to reach the standard quantum limit where spin projection noise is the dominant noise source limiting sensitivity. However, some axion models predict axion couplings to normal matter that would be too small for even a quantum limited CASPEr-e experiment to detect. This creates a need for surpassing the spin projection noise limit in NMR dark matter searches. In this thesis, I explore the prospects for surpassing the quantum limit in NMR by using spin squeezed states, entangled states with variance in one projection reduced below the standard quantum limit. First, I propose an experimental scheme for generating squeezed states by coupling the spins to an off-resonant circuit to create a One-Axis-Twist Hamiltonian. Then, using exact results and numerical simulations, I determine the amount of squeezing that can be achieved given decoherence and noise. Next, I perform modeling to show that squeezing can accelerate dark matter searches despite earlier results that argued squeezing cannot improve experimental sensitivity when subject to decoherence. Finally, I apply these results to the CASPEr-e experiment and show that at axion frequencies near 100MHz, squeezing can speed up the experiment by a factor of up to 30, corresponding to a sensitivity improvement by a factor of over 5.

•Jan 1, 2022•0 citations

Quantum magnetometry for space

Cameron Deans, T. Valenzuela, Mark G. Bason

The ability to measure the magnetic fields around celestial bodies enables various insights into processes and phenomena deep within such bodies.The use of magnetometry in space missions dates back to the 1950s, and a number of different technologies have been used to measure these fields, ranging from fluxgates to Anisotropic Magneto Resistance (AMR) sensors.Optically-pumped magnetometers (OPMs) represent the state-of-the-art in magnetic field sensitivity. 1 Such sensors rely upon the interaction of laser light to spin polarise a warm vapour of neutral atoms.Detecting the precession of these spins, again with laser light, is a direct way to measure a magnetic field and is relatable to fundamental constants.Improvements in quantum technology within the last decade have led to the miniaturisation of these sensors.We have now reached the point where compact, lightweight, and low power devices offer greater sensitivity to magnetic fields than any other technology.In this work, we identify the following four key space application areas in which OPMs may offer significant advantages over existing technologies: Environments in which high sensitivity is needed at low magnetic fields (10s of nT), full vector read-out with high directional sensitivity and reduced SWaP compared to helium magnetometers, miniaturised and lightweight scalar magnetometers to complement vector fluxgate measurements, vector or scalar sensors that need high (40 dB) gradiometer performance.This work identifies OPM configurations for each area and makes a first estimate of size, weight and power requirements for each.By enabling improvements in magnetic field sensitivity, this represents an exciting prospect for precision magnetic field measurements while also saving mass and reducing complexity.

International Conference on Space Optics (ICSO)•Jul 12, 2023•6 citations

Ultracold Atomic Magnetometry: Towards Quantum-Limited Sensing

Sula, Sindi

This thesis presents advancements in radio-frequency atomic magnetometry utilising cold atoms as sensors. While cold atom magnetometers demonstrate lower absolute sensitivity compared to conventional vapour cell systems due to reduced atom numbers, they offer exceptional spatial resolution at the micrometre scale. The experimental apparatus features a cold atom production system capable of reaching quantum degeneracy through a refined cooling sequence that involves optical molasses, magnetic trapping and evaporation, and optical evaporative cooling in the dipole trap, culminating in a 87Rb Bose-Einstein condensate. This work details the development and characterisation of magnetometer set-ups with progressively enhanced performance. The first magnetometer utilised atoms in the optical molasses phase as a sensor, achieving an AC sensitivity of 330 pT/√Hz with approximately 108 atoms at 20 μK. Comprehensive magnetometry optimisation methods were developed to enhance sensitivity. Following laboratory interruptions due to the COVID-19 pandemic, system rebuilding incorporated significant upgrades, including a new probe laser and gradient compensation systems. The improved magnetometer prototype achieved a substantially enhanced sensitivity of 0.72±0.33 pT/√Hz, approaching the fundamental sensitivity limit of the system. Using atoms in the magnetic trap as a sensor, a sensitivity of 1.85 pT/√Hz was demonstrated. The system was verified to be photon-shot noise limited. Investigations into a double-pass probe configuration showed that, while the measured sensitivity was similar to that of the single-pass (4.3 pT/√Hz compared to 3.1 pT/√Hz at a probe power of 6.4 μW measured at the detector), the rotation angle increased by a factor of 2.2, with significantly reduced noise levels. These findings suggest that multi-pass strategies hold promise for enhanced performance in future implementations. In addition, the first signal detection from a BEC magnetometer, achieving 4.5 nT/√Hz with only 95,000 atoms at 35 nK was demonstrated.

•Oct 28, 2025•0 citations

Spinor Bose-Einstein condensates in magnetic field gradients

A. A. Wood

Spinor Bose-Einstein condensates (BECs) are multi-component superfluids with magnetic interactions, formed from dilute gases of atoms in the Zeeman sublevels mF of a single hyperfine ground state F. Spinor BECs are inherently magnetic quantum objects, and exhibit a multitude of features such as spin domains, magnon excitations, and distinct magnetic phases. At the heart of the magnetic nature of a spinor BEC is the spin-dependent collisional interaction c, which determines the overall magnetic behaviour of the superfluid. In conjunction with the quadratic Zeeman shift q, the magnitude and sign of c give rise to an intricate magnetic phase diagram. The magnetic phase of a spinor BEC is tunable, and c and q are the knobs. In addition to realising quantum simulators of magnetism, spinor BECs are also precise magnetic sensors. Atomic magnetometry measures the Larmor precession frequency of atoms, which is proportional to the magnetic field strength. The sensitivity of an atomic magnetometer is principally dependent on the duration of the measurement (interrogation time) and number of atoms participating in the measurement. BECs are highly suitable as atomic magnetometers, allowing for long interrogation times and high atomic density, with microscopic sensor volumes. The latter is an important consideration, as measurement of small magnetic sources demand equally microscopic sensors. Established forms of magnetometry (such as warm vapour magnetometers) use large sensing volumes and are not trivially miniaturised. The exquisite sensitivity of a spinor BEC to magnetic fields becomes a liability when one studies low energy (~ 1 Hz) spinor physics over long evolution times (100 ms) in a typical laboratory environment. To first order, the spin-collisional interaction is independent of the magnetic field. However, spatially inhomogeneous magnetic fields are problematic, exerting mechanical forces on the magnetically sensitive spin components, suppressing spin collisions and possibly introducing relaxation mechanisms that confound the observation of intrinsic equilibration. Precise characterisation of magnetic field gradients and their cancellation is thus of paramount importance. In this thesis, the interaction of a spinor BEC with its environment is studied. The construction, operation and optimisation of a BEC machine is described in detail, as well as the quantum state preparation and control techniques used. Spin-mixing collisions were studied by observing population oscillations, the characteristic hallmark of such coherent phenomena. The observed population dynamics showed strong evidence of the deleterious effects of magnetic field gradients. A series of experiments were performed using spin-echo pulse sequences to decouple the evolving spinor condensate from the inhomogeneous magnetic environment with encouraging results, but which posed further questions. The fidelity of spin-echo pulses in the strong radiative coupling regime was also studied. Spinor condensates were then employed as sensitive magnetometers to characterise the magnetic landscape they inhabit. A new method of measuring magnetic field gradients was developed, using a pair of spinor BECs separated in space that are simultaneously addressed by a Ramsey interferometry sequence. Combined with a re-orientable magnetic bias field, the resulting gradiometer was used to measure the magnetic field gradient tensor in vacuo. This scheme can be extended to realise a high-precision vector co-magnetometer, with spatiotemporal sensitivity comparable to established forms of magnetometry. Vector light shifts (VLSs) are optically-induced energy shifts that result in effective magnetic fields, which in our case originate from the laser beams used to trap the atoms. The VLS vanishes for purely linearly polarised light, which is experimentally difficult to obtain in vacuo. Small elliptical polarisation imperfections originating from birefringent optics and the glass vacuum cell result in a non-zero shift that contaminates magnetometry measurements. The VLS is spatially varying due to the intensity gradient of the trapping light. Due to gravitational sag of the trapping potential, the spatial variation of the VLS is accentuated, resulting in an effective magnetic field gradient that contributes to dephasing and component separation. The simultaneous Ramsey interferometry experiments are then adapted to measure the VLS-induced Zeeman shift and diagnose its elimination. Up to 99.96% of the VLS is eliminated using this method, and extensions to the technique are described.

•Jan 1, 2017•0 citations
Since the 1950s, experiments searching for the neutron electric dipole moment have increased in sensitivity by six orders of magnitude. Yet, the current experimental sensitivity lies well above that predicted from standard model calculations. Corrections from physics beyond the standard model increase the predicted size of the nEDM, resulting in the nextgeneration of experiments hovering tantalisingly close to the detection sensitivity, to either verify or quash standard model extensions. One such experiment, n2EDM, currently in the commissioning stage at the Paul Scherrer Institute in Switzerland, hopes to measure the nEDM with a sensitivity improvement over its predecessor. This thesis details the design, measurement and analysis of hybrid 3He/alkali magnetometers for both accurate and precise magnetic field readings at low and zero fields, crucial for the development of ever-more sensitive fundamental physics searches. The work exploits the precise nature of alkali (87Rb and 133Cs) magnetometry techniques to measure the simultaneous Larmor precession of polarised 3He, avoiding light shifts commonly associated with optically pumped magnetometers. The first part of this work demonstrates the use of a hybrid 3He/87Rb magnetometer for the minimisation of remnant fields in a magnetically shielded environment, resulting in absolute low-field readings below 5 pT. Furthermore, the hybrid magnetometer was shown to be applicable for the reduction of gradient fields by optimising the effective 3He T2 time. This new technique represents a convenient and consistent way to achieve a near-zero magnetic field environment for precision experiments. Second, a new measurement technique was demonstrated using a hybrid 3He/133Cs magnetometer in a 1 µT field, placing experimental limits on the coupling of axion-like dark matter to nucleons. The measurement excluded axion coupling strength to 2:5 x 10-1 GeV-1 for axion masses between 10-20 to 10-17 eV at the 95% level. With the resulting exclusion region weaker than previous measurements, possible improvements to the apparatus should drive the development of a low-cost long-term axion interaction search.
Axions are a compelling dark matter candidate suggested by theories beyond the Standard Model. The predicted axion-electron coupling and the resulting pseudomagnetic field allow for laboratory axion searches. Here we report an experimental axion search via a superconductor-spin hybrid magnetometer. A state-of-the-art broadband magnetometer with a sensitivity of sub-100 aT/Hz1/2^{1/2}1/2 at tens of kHz has been realized by coupling a ferrite spin sensor to a readout system based on a superconducting quantum interference device. The most stringent terrestrial constraints on the axion-electron coupling have been established in the frequency range 5$\sim$60 kHz. In the future, an improvement on the constraints of more than 4 orders of magnitude is foreseeable through arrays of superconductor-spin hybrid magnetometers with optimized designs. This work demonstrates the potential of superconductor-spin hybrid magnetometers in high-precision magnetic field sensing and the study of fundamental physics.
The development of an experimental apparatus to produce Bose-Einstein condensates (BECs) of ⁸⁷Rb atoms and their application to magnetometry are discussed. Optical detection of atomic Larmor precession is a widely explored method for high-sensitivity measurements of magnetic fields. In this context, short laser/atom interaction time, atomic thermal diffusion and decoherence effects are among the main limitations. In this thesis, we overcome such problems by using spin-polarised ⁸⁷Rb ultra-cold atoms as the sensing element. After the atoms are polarised, a resonant pulse of radio-frequency excites Larmor precession, which is sensitive to external magnetic fields. By measuring the perturbations of the radio-frequency induced spin precession, information on the magnetic fields of interest. This is achieved by monitoring the polarisation plane’s rotation of a linearly polarised resonant laser probe. In the first part of this thesis, the building and optimisation of a laser-cooling set up to obtain a BEC in a hybrid trap is reported. In order to achieve the Phase Space Density (PSD) required for BEC, several different stages of trapping and cooling are necessary. Each phase has been implemented and optimised. The first step consists in the magneto-optical trap (MOT). Here a velocity dependent damping force and a spatially dependent confining force give the largest changes in PSD. Then atoms are loaded into a hybrid trap obtained by overlapping a quadrupole magnetic potential and a far detuned optical crossed dipole trap. The final stage for the condensation consists of forced evaporative cooling, both via magnetic and optical evaporation. In the second part of the thesis, a general overview of the principles of optical atomic magnetometry is provided and the advantages of using ultra-cold atoms with respect to conventional thermal vapours are discussed. The implementation, operation and a preliminary characterisation of the ultra-cold atom magnetometer are described along with the preliminary results collected. Finally, a plan for future improvements of its sensitivity is presented.
Direct detection of dark matter remains an important outstanding problem since abundant astrophysical evidence points towards its existence, but no experiment has succeeded in detecting it. Axions and axion-like-particles are some of the most compelling candidates for dark matter given their appearance in many theories of physics beyond the Standard Model and their relatively unexplored parameter space compared to other candidates. Recently, the Cosmic Axion Spin Precession Experiment-Electric (CASPEr-e) has used nuclear magnetic resonance (NMR) to search for effective magnetic fields created by axionic dark matter. By decreasing technical noise sources, CASPEr-e is projected to reach the standard quantum limit where spin projection noise is the dominant noise source limiting sensitivity. However, some axion models predict axion couplings to normal matter that would be too small for even a quantum limited CASPEr-e experiment to detect. This creates a need for surpassing the spin projection noise limit in NMR dark matter searches. In this thesis, I explore the prospects for surpassing the quantum limit in NMR by using spin squeezed states, entangled states with variance in one projection reduced below the standard quantum limit. First, I propose an experimental scheme for generating squeezed states by coupling the spins to an off-resonant circuit to create a One-Axis-Twist Hamiltonian. Then, using exact results and numerical simulations, I determine the amount of squeezing that can be achieved given decoherence and noise. Next, I perform modeling to show that squeezing can accelerate dark matter searches despite earlier results that argued squeezing cannot improve experimental sensitivity when subject to decoherence. Finally, I apply these results to the CASPEr-e experiment and show that at axion frequencies near 100MHz, squeezing can speed up the experiment by a factor of up to 30, corresponding to a sensitivity improvement by a factor of over 5.
The ability to measure the magnetic fields around celestial bodies enables various insights into processes and phenomena deep within such bodies.The use of magnetometry in space missions dates back to the 1950s, and a number of different technologies have been used to measure these fields, ranging from fluxgates to Anisotropic Magneto Resistance (AMR) sensors.Optically-pumped magnetometers (OPMs) represent the state-of-the-art in magnetic field sensitivity. 1 Such sensors rely upon the interaction of laser light to spin polarise a warm vapour of neutral atoms.Detecting the precession of these spins, again with laser light, is a direct way to measure a magnetic field and is relatable to fundamental constants.Improvements in quantum technology within the last decade have led to the miniaturisation of these sensors.We have now reached the point where compact, lightweight, and low power devices offer greater sensitivity to magnetic fields than any other technology.In this work, we identify the following four key space application areas in which OPMs may offer significant advantages over existing technologies: Environments in which high sensitivity is needed at low magnetic fields (10s of nT), full vector read-out with high directional sensitivity and reduced SWaP compared to helium magnetometers, miniaturised and lightweight scalar magnetometers to complement vector fluxgate measurements, vector or scalar sensors that need high (40 dB) gradiometer performance.This work identifies OPM configurations for each area and makes a first estimate of size, weight and power requirements for each.By enabling improvements in magnetic field sensitivity, this represents an exciting prospect for precision magnetic field measurements while also saving mass and reducing complexity.
This thesis presents advancements in radio-frequency atomic magnetometry utilising cold atoms as sensors. While cold atom magnetometers demonstrate lower absolute sensitivity compared to conventional vapour cell systems due to reduced atom numbers, they offer exceptional spatial resolution at the micrometre scale. The experimental apparatus features a cold atom production system capable of reaching quantum degeneracy through a refined cooling sequence that involves optical molasses, magnetic trapping and evaporation, and optical evaporative cooling in the dipole trap, culminating in a 87Rb Bose-Einstein condensate. This work details the development and characterisation of magnetometer set-ups with progressively enhanced performance. The first magnetometer utilised atoms in the optical molasses phase as a sensor, achieving an AC sensitivity of 330 pT/√Hz with approximately 108 atoms at 20 μK. Comprehensive magnetometry optimisation methods were developed to enhance sensitivity. Following laboratory interruptions due to the COVID-19 pandemic, system rebuilding incorporated significant upgrades, including a new probe laser and gradient compensation systems. The improved magnetometer prototype achieved a substantially enhanced sensitivity of 0.72±0.33 pT/√Hz, approaching the fundamental sensitivity limit of the system. Using atoms in the magnetic trap as a sensor, a sensitivity of 1.85 pT/√Hz was demonstrated. The system was verified to be photon-shot noise limited. Investigations into a double-pass probe configuration showed that, while the measured sensitivity was similar to that of the single-pass (4.3 pT/√Hz compared to 3.1 pT/√Hz at a probe power of 6.4 μW measured at the detector), the rotation angle increased by a factor of 2.2, with significantly reduced noise levels. These findings suggest that multi-pass strategies hold promise for enhanced performance in future implementations. In addition, the first signal detection from a BEC magnetometer, achieving 4.5 nT/√Hz with only 95,000 atoms at 35 nK was demonstrated.
Spinor Bose-Einstein condensates (BECs) are multi-component superfluids with magnetic interactions, formed from dilute gases of atoms in the Zeeman sublevels mF of a single hyperfine ground state F. Spinor BECs are inherently magnetic quantum objects, and exhibit a multitude of features such as spin domains, magnon excitations, and distinct magnetic phases. At the heart of the magnetic nature of a spinor BEC is the spin-dependent collisional interaction c, which determines the overall magnetic behaviour of the superfluid. In conjunction with the quadratic Zeeman shift q, the magnitude and sign of c give rise to an intricate magnetic phase diagram. The magnetic phase of a spinor BEC is tunable, and c and q are the knobs. In addition to realising quantum simulators of magnetism, spinor BECs are also precise magnetic sensors. Atomic magnetometry measures the Larmor precession frequency of atoms, which is proportional to the magnetic field strength. The sensitivity of an atomic magnetometer is principally dependent on the duration of the measurement (interrogation time) and number of atoms participating in the measurement. BECs are highly suitable as atomic magnetometers, allowing for long interrogation times and high atomic density, with microscopic sensor volumes. The latter is an important consideration, as measurement of small magnetic sources demand equally microscopic sensors. Established forms of magnetometry (such as warm vapour magnetometers) use large sensing volumes and are not trivially miniaturised. The exquisite sensitivity of a spinor BEC to magnetic fields becomes a liability when one studies low energy (~ 1 Hz) spinor physics over long evolution times (100 ms) in a typical laboratory environment. To first order, the spin-collisional interaction is independent of the magnetic field. However, spatially inhomogeneous magnetic fields are problematic, exerting mechanical forces on the magnetically sensitive spin components, suppressing spin collisions and possibly introducing relaxation mechanisms that confound the observation of intrinsic equilibration. Precise characterisation of magnetic field gradients and their cancellation is thus of paramount importance. In this thesis, the interaction of a spinor BEC with its environment is studied. The construction, operation and optimisation of a BEC machine is described in detail, as well as the quantum state preparation and control techniques used. Spin-mixing collisions were studied by observing population oscillations, the characteristic hallmark of such coherent phenomena. The observed population dynamics showed strong evidence of the deleterious effects of magnetic field gradients. A series of experiments were performed using spin-echo pulse sequences to decouple the evolving spinor condensate from the inhomogeneous magnetic environment with encouraging results, but which posed further questions. The fidelity of spin-echo pulses in the strong radiative coupling regime was also studied. Spinor condensates were then employed as sensitive magnetometers to characterise the magnetic landscape they inhabit. A new method of measuring magnetic field gradients was developed, using a pair of spinor BECs separated in space that are simultaneously addressed by a Ramsey interferometry sequence. Combined with a re-orientable magnetic bias field, the resulting gradiometer was used to measure the magnetic field gradient tensor in vacuo. This scheme can be extended to realise a high-precision vector co-magnetometer, with spatiotemporal sensitivity comparable to established forms of magnetometry. Vector light shifts (VLSs) are optically-induced energy shifts that result in effective magnetic fields, which in our case originate from the laser beams used to trap the atoms. The VLS vanishes for purely linearly polarised light, which is experimentally difficult to obtain in vacuo. Small elliptical polarisation imperfections originating from birefringent optics and the glass vacuum cell result in a non-zero shift that contaminates magnetometry measurements. The VLS is spatially varying due to the intensity gradient of the trapping light. Due to gravitational sag of the trapping potential, the spatial variation of the VLS is accentuated, resulting in an effective magnetic field gradient that contributes to dephasing and component separation. The simultaneous Ramsey interferometry experiments are then adapted to measure the VLS-induced Zeeman shift and diagnose its elimination. Up to 99.96% of the VLS is eliminated using this method, and extensions to the technique are described.