OSA Continuum

Influence of pump beam truncation on transverse relaxation time of 129Xe in a nuclear magnetic resonance gyroscope

Zhiguo Wang, Jiajia Li, Zhiqiang Xiong

Published Mar 15, 2020• 10 citations
Publisher

Abstract

In order to investigate the influence of pump beam truncation on the transverse relaxation time of 129Xe nuclear spins in a nuclear magnetic resonance gyroscope, we measured the transverse relaxation rate as a function of pump laser power and vapor cell temperature for two ovens with different optical access sizes. The experimental results conform qualitatively to a theoretical model based on magnetic field gradient induced by polarization gradient of Rb atoms. It is found that the non-uniform power distribution in the beam cross-section led to remarkable relaxation, especially for the 129Xe nuclear spins in a large-size vapor cell. To reduce the polarization gradient, the spatial distribution of the pump laser power in the cell should be as homogenous as possible. These results are of significance to the design of a high precision nuclear magnetic resonance gyroscope.

DOI
10.1364/osac.388223

Related papers

Effects of temperature on Rb and 129Xe spin polarization in a nuclear magnetic resonance gyroscope with low pump power

Linlin Chen, Binquan Zhou, Guanqun Lei +4 more

We propose an average Rb polarization model to analyze the influence of temperature on the spin polarization of Rb and 129Xe in a Nuclear Magnetic Resonance Gyroscope (NMRG) with low pump power. This model is essentially based on summing the Rb spin polarization along the direction of the pump beam and dividing the result by the cell length. We experimentally study the spin polarization of Rb and 129Xe atoms as a function of the cell temperature at low values of the pump power. The experimental results and the values calculated with the average Rb polarization model are in good agreement for both Rb and 129Xe. The spin polarization of Rb atoms decreases with increasing cell temperature, with a decreasing trend which is rapid at temperatures below 110 °C, and slower at temperatures above 110 °C. The experimental values of the 129Xe polarization, obtained with a pump power of 1 mW, first increase to a maximum P 129Xe−ave = 0.66 % at 118 °C, and then decreases as the temperature increases. Increasing the power of the pump beam shifts the temperature maximum to a higher value. Our model is suitable for the analysis of Rb and 129Xe polarization at high temperature and low pump power, i.e. when the power of the pump beam is completely absorbed within a few millimeters of the front window of the cell. Therefore, the present model can provide theoretical support for the improvement of the Signal-to-Noise-Ratio (SNR) of the NMRG, and to determine its optimal working temperature.

AIP Advances•Nov 1, 2017•36 citations

Investigation of spatial spin polarization of 87Rb and 129Xe atomic ensemble pumped by Gaussian beam in a miniature nuclear magnetic resonance gyroscope

Shu Qiang, Fang Ji

The spin polarization of 87Rb and 129Xe atomic ensemble has great impact on the signal intensity of a nuclear magnetic resonance gyroscope. The coupled spin polarization modelling process for 87Rb and 129Xe atoms ensemble is presented in detail. Three dimensional spatial distribution of the spin polarization field is obtained by numerical solution and is in good agreement with the experiment results. Influencing factors including temperature, power and detuned frequency of the pumping laser, average collision times of anti-relaxation coatings and partial pressure of gas composition are investigated. The work presents an indirect method to estimate the average collision times given the Xe polarization with different temperatures. It is found the average collision times of the 129Xe atoms with the inner surface of a bare glass cell of 3×3×3mm3 can reach up to about 2.7×105 times. It is also found that the pumping frequency corresponding to the maximum polarization of the Xe atoms polarized by spin exchange of Rb atoms is not consistent with the D1 line of the 87Rb atom when the temperature of the cell is above a certain temperature, but is detuned at a certain frequency. Quantitative analysis of the effect of anti-relaxation coatings on the spin polarization suggests that the appropriate average number of collisions of the Rb atoms with the inner surface of the cell is about 1500 times.

International Conference on Precision Instruments and Optical Engineering (PIOE)•Feb 27, 2023•1 citation

Comparative Measurement of Transverse Nuclear Magnetization of Polarized 129 Xe and 131 Xe by Spin-exch ange Optical Pumping

Yu. Ye Jin, Seong Ho Min, Han-Seb Moon

We analyze the transverse nuclear magnetizations of 129Xe and 131Xe in a vapor cell containing natural Xe, 87Rb, and buffer gases. The Xe atoms are polarized through spin-exchange optical pumping (SEOP) with Rb atoms under low-magnetic-field conditions. From the free-induction-decay (FID) signal, we measure the nuclear magnetization of the Xe atoms in the Xe-Rb vapor cell. Furthermore, we measure the dependence of the gyromagnetic ratio on the magnetization of 129Xe and 131Xe by examining the amplitude of the FID signal of each isotope, and we evaluate the relationship between the magnetic field gradient and transverse relaxation rate for both of the 129Xe and 131Xe isotopes.

Current Optics and Photonics•Dec 25, 2020•2 citations

Measuring Transverse Relaxation with a Single-Beam 894 nm VCSEL for Cs-Xe NMR Gyroscope Miniaturization

Qingyang Zhao, Ruochen Zhang, Hua Liu

The spin-exchange-pumped nuclear magnetic resonance gyroscope (NMRG) is a pivotal tool in quantum navigation. The transverse relaxation of atoms critically impacts the NMRG’s performance parameters and is essential for judging normal operation. Conventional methods for measuring transverse relaxation typically use dual beams, which involves complex optical path and frequency stabilization systems, thereby complicating miniaturization and integration. This paper proposes a method to construct a 133Cs parametric resonance magnetometer using a single-beam vertical-cavity surface-emitting laser (VCSEL) to measure the transverse relaxation of 129Xe and 131Xe. Based on this method, the volume of the gyroscope probe is significantly reduced to 50 cm3. Experimental results demonstrate that the constructed Cs-Xe NMRG can achieve a transverse relaxation time (T2) of 8.1 s under static conditions. Within the cell temperature range of 70 °C to 110 °C, T2 decreases with increasing temperature, while the signal amplitude inversely increases. The research lays the foundation for continuous measurement operations of miniaturized NMRGs.

Sensors•Sep 1, 2024•7 citations

Convenient measurement of 129Xe relaxation times without the influence of intensity gradient of pump laser

Tianyu Qian, Yang Zhang, Jintao Zheng +3 more

In the atomic cell of the spin exchange optical pumping system, the optical pumping inevitably introduces a magnetic field gradient, which affects the measurement result of the nuclear spin relaxation time a lot. To address this issue, our method achieves the measurement while excluding the influence of this magnetic field gradient. In this method, the pump laser is turned off after the spins of 87Rb and 129Xe have been effectively polarized, which results in the spin polarization of the 87Rb atoms being provided only by the spin exchange with 129Xe. Ultimately, the transverse and longitudinal components of the polarization of 129Xe are detected by the in situ87Rb atom magnetometer to obtain the T1 and T2 of 129Xe under different conditions. Using our method, since the influence of inhomogeneity caused by the pump laser is eliminated, the relaxation characteristic of atomic cells can be measured more quickly, essentially, and conveniently, which helps compare the performance of different atomic cells and find the best cell fabrication process further.

AIP Advances•Dec 1, 2023•0 citations

Measurement of a129Xe transverse relaxation rate without the influence of Rb polarization-induced magnetic gradient

Deok Young Lee, Sangkyung Lee, Sin Hyuk Yim

We demonstrate the measurement of the transverse spin relaxation rate of Xe without the influence of the Rb polarization-induced magnetic field gradient. The optical pumping beam and probe beam turn on and off repeatedly during the measurement to reduce the relaxation originating from the Rb polarization-induced magnetic field gradient. During the absence of the optical pumping beam, the nuclear spin of the noble gas atom does not experience the alkali-polarization-induced magnetic field gradient so that the transverse spin relaxation rate ( 1 / T 2 ) decreases. When the duty cycle reaches zero, the measured transverse relaxation time T 2 approaches the longitudinal spin relaxation time T 1 . Our method helps in roughly estimating the longitudinal spin relaxation time with a single measurement of the free induction decay.

Applied Optics•Jul 12, 2021•23 citations
In order to investigate the influence of pump beam truncation on the transverse relaxation time of 129Xe nuclear spins in a nuclear magnetic resonance gyroscope, we measured the transverse relaxation rate as a function of pump laser power and vapor cell temperature for two ovens with different optical access sizes. The experimental results conform qualitatively to a theoretical model based on magnetic field gradient induced by polarization gradient of Rb atoms. It is found that the non-uniform power distribution in the beam cross-section led to remarkable relaxation, especially for the 129Xe nuclear spins in a large-size vapor cell. To reduce the polarization gradient, the spatial distribution of the pump laser power in the cell should be as homogenous as possible. These results are of significance to the design of a high precision nuclear magnetic resonance gyroscope.
We propose an average Rb polarization model to analyze the influence of temperature on the spin polarization of Rb and 129Xe in a Nuclear Magnetic Resonance Gyroscope (NMRG) with low pump power. This model is essentially based on summing the Rb spin polarization along the direction of the pump beam and dividing the result by the cell length. We experimentally study the spin polarization of Rb and 129Xe atoms as a function of the cell temperature at low values of the pump power. The experimental results and the values calculated with the average Rb polarization model are in good agreement for both Rb and 129Xe. The spin polarization of Rb atoms decreases with increasing cell temperature, with a decreasing trend which is rapid at temperatures below 110 °C, and slower at temperatures above 110 °C. The experimental values of the 129Xe polarization, obtained with a pump power of 1 mW, first increase to a maximum P 129Xe−ave = 0.66 % at 118 °C, and then decreases as the temperature increases. Increasing the power of the pump beam shifts the temperature maximum to a higher value. Our model is suitable for the analysis of Rb and 129Xe polarization at high temperature and low pump power, i.e. when the power of the pump beam is completely absorbed within a few millimeters of the front window of the cell. Therefore, the present model can provide theoretical support for the improvement of the Signal-to-Noise-Ratio (SNR) of the NMRG, and to determine its optimal working temperature.
The spin polarization of 87Rb and 129Xe atomic ensemble has great impact on the signal intensity of a nuclear magnetic resonance gyroscope. The coupled spin polarization modelling process for 87Rb and 129Xe atoms ensemble is presented in detail. Three dimensional spatial distribution of the spin polarization field is obtained by numerical solution and is in good agreement with the experiment results. Influencing factors including temperature, power and detuned frequency of the pumping laser, average collision times of anti-relaxation coatings and partial pressure of gas composition are investigated. The work presents an indirect method to estimate the average collision times given the Xe polarization with different temperatures. It is found the average collision times of the 129Xe atoms with the inner surface of a bare glass cell of 3×3×3mm3 can reach up to about 2.7×105 times. It is also found that the pumping frequency corresponding to the maximum polarization of the Xe atoms polarized by spin exchange of Rb atoms is not consistent with the D1 line of the 87Rb atom when the temperature of the cell is above a certain temperature, but is detuned at a certain frequency. Quantitative analysis of the effect of anti-relaxation coatings on the spin polarization suggests that the appropriate average number of collisions of the Rb atoms with the inner surface of the cell is about 1500 times.
We analyze the transverse nuclear magnetizations of 129Xe and 131Xe in a vapor cell containing natural Xe, 87Rb, and buffer gases. The Xe atoms are polarized through spin-exchange optical pumping (SEOP) with Rb atoms under low-magnetic-field conditions. From the free-induction-decay (FID) signal, we measure the nuclear magnetization of the Xe atoms in the Xe-Rb vapor cell. Furthermore, we measure the dependence of the gyromagnetic ratio on the magnetization of 129Xe and 131Xe by examining the amplitude of the FID signal of each isotope, and we evaluate the relationship between the magnetic field gradient and transverse relaxation rate for both of the 129Xe and 131Xe isotopes.
The spin-exchange-pumped nuclear magnetic resonance gyroscope (NMRG) is a pivotal tool in quantum navigation. The transverse relaxation of atoms critically impacts the NMRG’s performance parameters and is essential for judging normal operation. Conventional methods for measuring transverse relaxation typically use dual beams, which involves complex optical path and frequency stabilization systems, thereby complicating miniaturization and integration. This paper proposes a method to construct a 133Cs parametric resonance magnetometer using a single-beam vertical-cavity surface-emitting laser (VCSEL) to measure the transverse relaxation of 129Xe and 131Xe. Based on this method, the volume of the gyroscope probe is significantly reduced to 50 cm3. Experimental results demonstrate that the constructed Cs-Xe NMRG can achieve a transverse relaxation time (T2) of 8.1 s under static conditions. Within the cell temperature range of 70 °C to 110 °C, T2 decreases with increasing temperature, while the signal amplitude inversely increases. The research lays the foundation for continuous measurement operations of miniaturized NMRGs.
In the atomic cell of the spin exchange optical pumping system, the optical pumping inevitably introduces a magnetic field gradient, which affects the measurement result of the nuclear spin relaxation time a lot. To address this issue, our method achieves the measurement while excluding the influence of this magnetic field gradient. In this method, the pump laser is turned off after the spins of 87Rb and 129Xe have been effectively polarized, which results in the spin polarization of the 87Rb atoms being provided only by the spin exchange with 129Xe. Ultimately, the transverse and longitudinal components of the polarization of 129Xe are detected by the in situ87Rb atom magnetometer to obtain the T1 and T2 of 129Xe under different conditions. Using our method, since the influence of inhomogeneity caused by the pump laser is eliminated, the relaxation characteristic of atomic cells can be measured more quickly, essentially, and conveniently, which helps compare the performance of different atomic cells and find the best cell fabrication process further.
We demonstrate the measurement of the transverse spin relaxation rate of Xe without the influence of the Rb polarization-induced magnetic field gradient. The optical pumping beam and probe beam turn on and off repeatedly during the measurement to reduce the relaxation originating from the Rb polarization-induced magnetic field gradient. During the absence of the optical pumping beam, the nuclear spin of the noble gas atom does not experience the alkali-polarization-induced magnetic field gradient so that the transverse spin relaxation rate ( 1 / T 2 ) decreases. When the duty cycle reaches zero, the measured transverse relaxation time T 2 approaches the longitudinal spin relaxation time T 1 . Our method helps in roughly estimating the longitudinal spin relaxation time with a single measurement of the free induction decay.