The emerging field of quantum imaging introduces new methods to overcome classical limitations in optical microscopy. A detection apparatus capable of analyzing the quantum signature of light, is a crucial component in the heart of any such method. We present a novel quantum imaging modality, based on a state-of-the-art single photon avalanche diode (SPAD) array in a confocal setup. This modality enables unprecedented simplicity and scalability in imaging temporal photon correlations. We demonstrate the potential of this approach by measuring temporal correlations of classical and quantum sources, as well as demonstrate a quantum super-resolution technique.
The emerging field of quantum imaging introduces new methods to overcome classical limitations in optical microscopy. A detection apparatus capable of analyzing the quantum signature of light, is a crucial component in the heart of any such method. We present a novel quantum imaging modality, based on a state-of-the-art single photon avalanche diode (SPAD) array in a confocal setup. This modality enables unprecedented simplicity and scalability in imaging temporal photon correlations. We demonstrate the potential of this approach by measuring temporal correlations of classical and quantum sources, as well as demonstrate a quantum super-resolution technique.
By harnessing the properties of photonic quantum states and their interaction with the environment, quantum imaging promises to go beyond the limits of classical imaging. However, the inherent weakness of detected signals and the fragility of quantum states make their properties difficult to measure in practice. In recent years, the emergence of single-photon sensitive cameras enabled the field to take a step closer to practical applications. In this respect, singlephoton avalanche diode (SPAD) cameras are one the most promising technologies as they can detect single photons across many pixels with unparalleled speed, temporal resolution, and very low noise.
Single-photon avalanche diode (SPAD) arrays are essential tools in biophotonics, optical ranging and sensing, and quantum optics. However, their small number of pixels, low quantum efficiency, and small fill factor have so far hindered their use for practical imaging applications. Here, we demonstrate full-field entangled photon-pair correlation imaging using a 100-kpixel SPAD camera. By measuring photon coincidences between more than 500 million pairs of positions, we retrieve the full point spread function of the imaging system and subsequently high-resolution images of target objects illuminated by spatially entangled photon pairs. We show that our imaging approach is robust against stray light, enabling quantum imaging technologies to move beyond laboratory experiments towards real-world applications such as quantum light detection and ranging.
CMOS, detector arrays, interferometer, phase twinning, quantum imaging, SPAD (single photon avalanche diode) We continue our previous program where we introduced a set of quantum-based design rules directed at quantum engineers who design single-photon quantum communications and quantum imaging devices. Here, we report on experimental progress using SPAD (single photon avalanche diode) arrays of our design and fabricated in CMOS (complementary metal oxide semiconductor) technology. Emerging high-resolution imaging techniques based on SPAD arrays have proven useful in a variety of disciplines including bio-fluorescence microscopy and 3D vision systems. They have also been
Temporal photon correlations have been a crucial resource for quantum and quantum-enabled optical science for over half a century. However, attaining non-classical information through these correlations has typically been limited to a single point (or, at best, a few points) at a time. Here, we perform a massively multiplexed wide-field photon correlation measurement using a large single-photon avalanche diode array, the SwissSPAD3. We demonstrate the performance of this apparatus by acquiring wide-field photon correlation measurements of single-photon emitters and illustrate two applications of the attained quantum information: wide-field emitter counting and quantum-enabled super-resolution imaging (by a factor of 500×500). The considerations and limitations of applying this technique in a practical context are discussed. Ultimately, the realization of massively multiplexed wide-field photon correlation measurements can accelerate quantum sensing protocols and quantum-enabled imaging techniques by orders of magnitude.
Quantum techniques are commonly used to enhance measurement performance in many fields, such as imaging, microscopy, communications, computing and metrology. In quantum imaging and microscopy, entangled photons are exploited to improve image resolution and sensitivity, overcoming the diffraction limit and providing Sub-Shot Noise (SSN) measurements [1] . Super resolution imaging, SSN imaging, quantum-enhanced displacement sensing, correlation plenoptic imaging and ghost imaging are different quantum techniques used to enhance image quality. All them require time-resolved single-photon detectors, capable to detect photon coincidences with sub-nanosecond precision.
The ability to generate and handle quantum correlations in twin-beam states is the foundation to overcome the imaging limitations imposed by classical light [1], relying on efficient detectors able to select temporal correlations among photons with maximized signal-to-noise ratio. Indeed, quantum information is contained in the interaction with the sample of just two photons, thus losing even one of them or mixing them up with background can completely compromise the experiment. To this end, assessing and evaluating the expected probability of measurement errors is of utmost importance to optimize the detector design. A typical experimental setup of a quantum imaging system based on Spontaneous Parametric Down Conversion (SPDC), the most effective way of producing temporally and spatially correlated entangled photons [2], involves a pump laser hitting a non-linear birefringent crystal producing a down-converted signal, some passive optical components to generate polarization-entangled photons and a pixelated photon detector that eventually reveals the position of coincident entangled photons. The overall detection efficiency of the measurement setup (i.e. heralding efficiency ηH) gathers all its possible losses and non-idealities of the mentioned setup components, namely the crystal conversion efficiency, the optical losses, the detector Photon Detection Efficiency (PDE) and fill-factor. In this study, we consider a detection based on a Single Photon Avalanche Diode (SPAD) array, able to detect coincidences on-chip and with event-driven architecture, which provides fast readout, low power consumption and optimized data throughput. However, related to every on-chip coincidence detection and event-driven based architecture, some operations require a certain amount of time to be performed that, combined with the generation of undesired single photons (both due to limited heralding efficiency and SPAD Dark Count Rate, DCR), yield to three measurement errors, here described with their related probabilities. Firstly, due to the finite duration of the coincidence window ∆tCOINC, there exist a probability Pfalseof wrongly detecting as coincident photons two single photons, and can be expressed as:\begin{equation*}{P_{false}} = \frac{{\left[ {2{\mu _{SOURCE{\text{ }}}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\left( {1 - {e^{ - \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\Delta {t_{COINC}}}}} \right)}}{{{\mu _{SOURCE}}\eta _H^2 + \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + DCR} \right]\left( {1 - {e^{ - \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\Delta {t_{COINC}}}}} \right)}}\tag{1}\end{equation*}where µSOURCEis the number of photon pairs generated by an ideal non-linear crystal. Secondly, in the time needed for the array to "freeze" the pixels state after a coincidence event (∆tFREEZE) so that they can be readout, there is the probability Pspuriousof detecting a third spurious event after a coincidence has been detected, which is expressed as:\begin{equation*}{P_{spurious}} = 1 - {e^{ - \left[ {2{\mu _{SOURCE\eta }}_H\left( {1 - {\eta _H}} \right) + DCR} \right]\Delta {t_{FREEZE}}}}\tag{2}\end{equation*}