Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

APS

Large Momentum Separation Contrast Interferometry with Yb Bose-Einstein condensates

Katherine E. McAlpine, Daniel Gochnauer, Benjamin Plotkin-Swing, Subhadeep Gupta

Published May 1, 2018• 0 citations
OpenAlex

Related papers

Precision Contrast Interferometry with Yb Bose-Einstein condensates for $h/m$ and $\alpha$

Daniel Gochnauer, Katherine E. McAlpine, Benjamin Plotkin-Swing +1 more

Bulletin of the American Physical Society•May 29, 2018•0 citations

High contrast interferometry and finite temperature coherence of Bose-Einstein condensates

Christopher Carson

•Jan 1, 2015•0 citations

Construction of next generation Yb Bose-Einstein condensate interferometer

Benjamin Plotkin-Swing, Alan O. Jamison, Anupriya Jayakumar +4 more

Bulletin of the American Physical Society•Jun 3, 2014•0 citations

Advances in precision contrast interferometry with Yb Bose-Einstein condensates

Alan O. Jamison, Benjamin Plotkin-Swing, Subhadeep Gupta

Using a three-path contrast interferometer (CI) geometry and laser-pulse diffraction gratings, we create a matter-wave interferometer with ytterbium (Yb) atoms. We present advances in contrast interferometry relevant to high-precision measurements. By comparing to a traditional atom interferometer, we demonstrate the immunity of the CI to vibrations for long interaction times ($>20\phantom{\rule{0.28em}{0ex}}\mathrm{ms}$). We characterize and demonstrate control over the two largest systematic effects for a high-precision measurement of the fine-structure constant via photon recoil with our interferometer: diffraction phases and atomic interactions. Diffraction phases are an important systematic for most interferometers using large-momentum transfer beam splitters; atomic interactions are a key concern for any Bose-Einstein condensate (BEC) interferometer. Finally, we consider the prospects for a future subpart per billion photon recoil measurement using a Yb CI.

arXiv:1404.6028•Physical Review A•Dec 1, 2014•44 citations

Precision Interferometry with Bose-Einstein Condensates

Alan O. Jamison

This dissertation describes the creation of the first matter-wave interferometer using ytterbium (Yb) atoms. Most of the experiments focus on a contrast interferometer geometry with a Bose-Einstein condensate (BEC) as source. The recoil frequency of the 174-Yb atom is measured with this interferometer. The recoil frequency of an atom is part of a set of precision measurements that together give a value for the fine structure constant. The experimental results of this dissertation lay the groundwork for a future sub part-per-billion (ppb) precision measurement of the Yb recoil frequency. The contrast interferometry technique is extended to substantially longer times scales than those achieved in previous experiments. A measurement at the ~10 parts-per-million level is made. Systematic effects and statistical scaling are studied and found to be compatible with the desired sub-ppb precision for a future measurement. Such a measurement requires a detailed theoretical study of possible systematic shifts to the measured value. A substantial portion of this dissertation consists of this analysis, carried out in sufficient generality as to guide future sub-ppb level measurements. In addition to a large number of possible systematic shifts due to well-understood physics, two more complex effects are identified and studied: Diffraction phases and atom-atom interactions.

•Jan 1, 2014•5 citations

Large Momentum Separation Matter Wave Interferometry

Benjamin Plotkin-Swing

This work establishes a new benchmark for momentum separation in a matter wave interferometer with stable, visible fringes. With a path separation of 112 photon recoil momenta, our signal visibility of 30% and phase stability of 0.6rad exceed the performance of earlier free space interferometers. Contributing to this success are the symmetric form of the 3 path contrast interferometer geometry, which rejects phase noise due to vibrations and other systematic errors, the narrow momentum width of the Bose-Einstein condensate (BEC) source, and atom-optics parameters chosen to suppress unwanted diffraction phases. These results can be applied toward a competitive measurement of the fine-structure constant and a test of QED. The described experiments were performed in a new ytterbium BEC apparatus whose design, construction, and operation is documented here.

•Apr 24, 2018•4 citations
Precision Contrast Interferometry with Yb Bose-Einstein condensates for h/mh/mh/m and α\alphaα
Using a three-path contrast interferometer (CI) geometry and laser-pulse diffraction gratings, we create a matter-wave interferometer with ytterbium (Yb) atoms. We present advances in contrast interferometry relevant to high-precision measurements. By comparing to a traditional atom interferometer, we demonstrate the immunity of the CI to vibrations for long interaction times (>20ms>20\phantom{\rule{0.28em}{0ex}}\mathrm{ms}>20ms). We characterize and demonstrate control over the two largest systematic effects for a high-precision measurement of the fine-structure constant via photon recoil with our interferometer: diffraction phases and atomic interactions. Diffraction phases are an important systematic for most interferometers using large-momentum transfer beam splitters; atomic interactions are a key concern for any Bose-Einstein condensate (BEC) interferometer. Finally, we consider the prospects for a future subpart per billion photon recoil measurement using a Yb CI.
This dissertation describes the creation of the first matter-wave interferometer using ytterbium (Yb) atoms. Most of the experiments focus on a contrast interferometer geometry with a Bose-Einstein condensate (BEC) as source. The recoil frequency of the 174-Yb atom is measured with this interferometer. The recoil frequency of an atom is part of a set of precision measurements that together give a value for the fine structure constant. The experimental results of this dissertation lay the groundwork for a future sub part-per-billion (ppb) precision measurement of the Yb recoil frequency. The contrast interferometry technique is extended to substantially longer times scales than those achieved in previous experiments. A measurement at the ~10 parts-per-million level is made. Systematic effects and statistical scaling are studied and found to be compatible with the desired sub-ppb precision for a future measurement. Such a measurement requires a detailed theoretical study of possible systematic shifts to the measured value. A substantial portion of this dissertation consists of this analysis, carried out in sufficient generality as to guide future sub-ppb level measurements. In addition to a large number of possible systematic shifts due to well-understood physics, two more complex effects are identified and studied: Diffraction phases and atom-atom interactions.
This work establishes a new benchmark for momentum separation in a matter wave interferometer with stable, visible fringes. With a path separation of 112 photon recoil momenta, our signal visibility of 30% and phase stability of 0.6rad exceed the performance of earlier free space interferometers. Contributing to this success are the symmetric form of the 3 path contrast interferometer geometry, which rejects phase noise due to vibrations and other systematic errors, the narrow momentum width of the Bose-Einstein condensate (BEC) source, and atom-optics parameters chosen to suppress unwanted diffraction phases. These results can be applied toward a competitive measurement of the fine-structure constant and a test of QED. The described experiments were performed in a new ytterbium BEC apparatus whose design, construction, and operation is documented here.