Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

A Numerical Analysis of Interaction-free Measurement With a Shot-Noise-Limited Electron Source and Conditional Sample Re-illumination

Akshay Agarwal, Vivek K Goyal, Karl K. Berggren

Published Mar 8, 2018• 0 citations
OpenAlex

Related papers

Reduced damage in electron microscopy by using interaction-free measurement and conditional reillumination

Akshay Agarwal, Karl K. Berggren, Yuri J. van Staaden +1 more

Interaction-free measurement (IFM) has been proposed as a means of high-resolution, low-damage imaging of radiation-sensitive samples, such as biomolecules and proteins. The basic setup for IFM is a Mach-Zehnder interferometer, and recent progress in nanofabricated electron-diffraction gratings has made it possible to incorporate a Mach-Zehnder interferometer in a transmission electron microscope (TEM). Therefore, the limits of performance of IFM with such an interferometer and a shot-noise limited electron source (such as that in a TEM) are of interest. In this paper, we compare the error probability and sample damage for ideal IFM and classical imaging schemes, through theoretical analysis and numerical simulation. We consider a sample that is either completely transparent or completely opaque at each pixel. In our analysis, we also evaluate the impact of an additional detector for scattered electrons. Inclusion of the scattering detector results in reduction of error by up to an order of magnitude, for both IFM and classical schemes. We also investigate a sample reillumination scheme based on updating priors after each round of illumination and find that this scheme further reduces error. Implementation of these methods is likely achievable with existing instrumentation and would result in improved resolution in low-dose electron microscopy.

arXiv:1901.09702•Physical Review A•Jun 5, 2019•12 citations

Experimental Realization of Interaction‐free Measurementsa

Paul G. Kwiat, Harald Weinfurter, Thomas Herzog +2 more

Annals of the New York Academy of Sciences•Apr 1, 1995•42 citations

Classical Inputs and Measurements Enable Phase Sensitivity beyond the Shot-Noise Limit

Jiandong Zhang, Zijing Zhang, Longzhu Cen +2 more

Coherent-state-based phase estimation is a fruitful testbed for the field of precision measurements since coherent states are robust to decoherence when compared with exotic quantum states. The seminal work done by Caves (https://doi.org/10.1103/PhysRevD.23.1693 , Phys. Rev. D 23, 1693 (1981)) stated that the phase sensitivity of a U(2) interferometer fed with a coherent state is limited by the shot-noise limit (SNL). In this Letter, we demonstrate that this bound is not conclusive sensitivity limit and can be broken when the measurement includes an external phase reference. The SNL can be surpassed by a factor of $\sqrt{2}$ and the validity is supported through the calculation of quantum Fisher information. Additionally, we discuss other single-mode Gaussian inputs of which sensitivities are beyond the SNL. Our work shows potential applications for many metological scenarios, particularly when the measured samples immersed in great lossy environments or can withstand bright illumination.

arXiv:2001.00160•Jan 1, 2020•1 citation

Interaction-free Interferometry with Electrons

Amy E. Turner, Cameron Johnson, Benjamin J. McMorran

Microscopy and Microanalysis•Jul 30, 2020•1 citation

Bayesian Optimization of Interaction Free Measurement with Electrons

Nicolas Puentes, Benjamin M McMorran

High energy electrons enable atomic resolution, but also engender radiolysis or ionization damage to beam-sensitive materials, hampering the atomic imaging of medically and technologically relevant materials/processes such as cellular dynamics and proteomics. The dose required to resolve beam-sensitive materials usually far exceeds its critical dose, requiring dose dispersion across identically prepared samples that incur extensive computational processing and precise sample preparation. Numerous techniques are proposed and employed to minimize ionization damage while maximizing information acquired. The Elitzur and Vaidman quantum bomb detector is one such method [1], involving interaction-free measurements (IFM) [2-3]. In the thought experiment of Elitzur and Vaidman, single particles that are spacelike separated pass through an aligned Mach–Zehnder interferometer such that the particles self-interfere resulting in detections only at the bright port (Fig. 1(a)). Inserting an opaque object into the interferometer, disrupts the self-interference of the particles such that detections occur at the dark port (Fig. 1(b)). These dark port detections (IFMs) inform on the presence of the opaque object without the particles directly interacting with it. This phenomena extends to phase objects enabling quantitative phase imaging using interaction free measurements. A two-grating Mach–Zehnder interferometer (2GMZI) was constructed in a Titan TEM to realize IFM with electrons [4]. Now we construct the 2GMZI in a Spectra TEM similarly as before and is schematically shown in Figure 1(c). There are numerous new features from the previous generation Titan TEM pertinent to 2GMZI—such as a cold FEG and a Dectris ELA (direct electron) detector—improving electron coherence and signal-to-noise of the dark port. In the interim between the 2GMZI setups, analyses and simulations were performed to optimize the two nanofabricated gratings in mill pattern and configuration. Here we discuss such grating optimizations with an objective to maximize the Fisher information per unit radiation damage in beam-sensitive materials. The Fisher information (FIM) of interest quantifies the expected information in the detected electrons about phase differences imparted by the specimen (see Figure 2). The FIM is tunable by varying the proportion of electrons propagating via each path determined by the gratings. For instance, the pump probe configuration—where the pump carries most electrons through vacuum and the probe passes through the sample—minimizes radiation damage to the sample, but reduces the Fisher information and increases background noise via longer imaging sessions to acquire the necessary signal. The output grating may also be tuned to create multiple dark ports, increasing the overall signal. The interplay between minimizing radiation damage while maximizing the Fisher information leads to many local solutions where the global solution status depends on the critical dose of samples and the background shot noise. Utilizing these global solution configurations of 2GMZI for IFM imaging will improve low-dose phase imaging of beam-sensitive materials, decreasing the dose for high resolution imaging [5]. Sub figures (a) and (b) illustrate an electron, Mach–Zehnder interferometer in which traditional optical components—such as beam splitters and mirrors—are interchanged for gratings and magnetic lenses. Inserting an opaque object (b), prevents deconstructive interference at the dark port (DP), enabling interaction free measurements. Sub figure (c) further details the implementation of a Mach–Zehnder interferometer in an electron microscope. These two sub figures were simulated using two incident probes in the sample plane like Figure 1(c), and the specimen-induced phase-difference is swept. Sub figure (a) shows the normalized intensity of the modes, in which mode -1 and 0 correspond to the dark and bright port, respectively. Sub figure (b) is the corresponding Fisher information for each respective mode. The outer modes should be ideally suppressed.

Microscopy and Microanalysis•Jul 1, 2026•0 citations

Diffraction-based interaction-free measurements

Spencer Rogers, Yakir Aharonov, Cyril Elouard +1 more

arXiv:1907.05977•Quantum Studies Mathematics and Foundations•Sep 14, 2019•1 citation
Interaction-free measurement (IFM) has been proposed as a means of high-resolution, low-damage imaging of radiation-sensitive samples, such as biomolecules and proteins. The basic setup for IFM is a Mach-Zehnder interferometer, and recent progress in nanofabricated electron-diffraction gratings has made it possible to incorporate a Mach-Zehnder interferometer in a transmission electron microscope (TEM). Therefore, the limits of performance of IFM with such an interferometer and a shot-noise limited electron source (such as that in a TEM) are of interest. In this paper, we compare the error probability and sample damage for ideal IFM and classical imaging schemes, through theoretical analysis and numerical simulation. We consider a sample that is either completely transparent or completely opaque at each pixel. In our analysis, we also evaluate the impact of an additional detector for scattered electrons. Inclusion of the scattering detector results in reduction of error by up to an order of magnitude, for both IFM and classical schemes. We also investigate a sample reillumination scheme based on updating priors after each round of illumination and find that this scheme further reduces error. Implementation of these methods is likely achievable with existing instrumentation and would result in improved resolution in low-dose electron microscopy.
Coherent-state-based phase estimation is a fruitful testbed for the field of precision measurements since coherent states are robust to decoherence when compared with exotic quantum states. The seminal work done by Caves (https://doi.org/10.1103/PhysRevD.23.1693 , Phys. Rev. D 23, 1693 (1981)) stated that the phase sensitivity of a U(2) interferometer fed with a coherent state is limited by the shot-noise limit (SNL). In this Letter, we demonstrate that this bound is not conclusive sensitivity limit and can be broken when the measurement includes an external phase reference. The SNL can be surpassed by a factor of 2\sqrt{2}2​ and the validity is supported through the calculation of quantum Fisher information. Additionally, we discuss other single-mode Gaussian inputs of which sensitivities are beyond the SNL. Our work shows potential applications for many metological scenarios, particularly when the measured samples immersed in great lossy environments or can withstand bright illumination.
High energy electrons enable atomic resolution, but also engender radiolysis or ionization damage to beam-sensitive materials, hampering the atomic imaging of medically and technologically relevant materials/processes such as cellular dynamics and proteomics. The dose required to resolve beam-sensitive materials usually far exceeds its critical dose, requiring dose dispersion across identically prepared samples that incur extensive computational processing and precise sample preparation. Numerous techniques are proposed and employed to minimize ionization damage while maximizing information acquired. The Elitzur and Vaidman quantum bomb detector is one such method [1], involving interaction-free measurements (IFM) [2-3]. In the thought experiment of Elitzur and Vaidman, single particles that are spacelike separated pass through an aligned Mach–Zehnder interferometer such that the particles self-interfere resulting in detections only at the bright port (Fig. 1(a)). Inserting an opaque object into the interferometer, disrupts the self-interference of the particles such that detections occur at the dark port (Fig. 1(b)). These dark port detections (IFMs) inform on the presence of the opaque object without the particles directly interacting with it. This phenomena extends to phase objects enabling quantitative phase imaging using interaction free measurements. A two-grating Mach–Zehnder interferometer (2GMZI) was constructed in a Titan TEM to realize IFM with electrons [4]. Now we construct the 2GMZI in a Spectra TEM similarly as before and is schematically shown in Figure 1(c). There are numerous new features from the previous generation Titan TEM pertinent to 2GMZI—such as a cold FEG and a Dectris ELA (direct electron) detector—improving electron coherence and signal-to-noise of the dark port. In the interim between the 2GMZI setups, analyses and simulations were performed to optimize the two nanofabricated gratings in mill pattern and configuration. Here we discuss such grating optimizations with an objective to maximize the Fisher information per unit radiation damage in beam-sensitive materials. The Fisher information (FIM) of interest quantifies the expected information in the detected electrons about phase differences imparted by the specimen (see Figure 2). The FIM is tunable by varying the proportion of electrons propagating via each path determined by the gratings. For instance, the pump probe configuration—where the pump carries most electrons through vacuum and the probe passes through the sample—minimizes radiation damage to the sample, but reduces the Fisher information and increases background noise via longer imaging sessions to acquire the necessary signal. The output grating may also be tuned to create multiple dark ports, increasing the overall signal. The interplay between minimizing radiation damage while maximizing the Fisher information leads to many local solutions where the global solution status depends on the critical dose of samples and the background shot noise. Utilizing these global solution configurations of 2GMZI for IFM imaging will improve low-dose phase imaging of beam-sensitive materials, decreasing the dose for high resolution imaging [5]. Sub figures (a) and (b) illustrate an electron, Mach–Zehnder interferometer in which traditional optical components—such as beam splitters and mirrors—are interchanged for gratings and magnetic lenses. Inserting an opaque object (b), prevents deconstructive interference at the dark port (DP), enabling interaction free measurements. Sub figure (c) further details the implementation of a Mach–Zehnder interferometer in an electron microscope. These two sub figures were simulated using two incident probes in the sample plane like Figure 1(c), and the specimen-induced phase-difference is swept. Sub figure (a) shows the normalized intensity of the modes, in which mode -1 and 0 correspond to the dark and bright port, respectively. Sub figure (b) is the corresponding Fisher information for each respective mode. The outer modes should be ideally suppressed.