Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

APS

Frequency measurements of cold-atom clocks

Scott A. Diddams

Published Apr 1, 2001• 1 citation
OpenAlex

Related papers

Atomic Clocks and Cold Atom Scattering

Chad Fertig, Ronald Legere, J.Irfon Rees +3 more

Springer eBooks•Jan 1, 2003•1 citation

Scattering of cold atom coherences by hot atoms: Background gas collision shifts of primary fountain clocks

Kurt Gibble

We theoretically analyze frequency shifts of cold-atom clocks due to background gas collisions. Because nearly all collisions with room-temperature background gases that transfer momentum eject cold atoms from a clock, the frequency shifts for cold atoms are significantly different than those of room-temperature clocks. From general arguments, measurements of the loss of Ramsey fringe amplitude can usefully bound this source of systematic error.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2013•2 citations

Microwave interrogation cavity for the rubidium space cold atom clock

Wei Ren, Yuan-Ci Gao, Tang Li +2 more

The performance of space cold atom clocks (SCACs) should be improved thanks to the microgravity environment in space. The microwave interrogation cavity is a key element in a SCAC. In this paper, we develop a microwave interrogation cavity especially for the rubidium SCAC. The interrogation cavity has two microwave interaction zones with a single feed-in source, which is located at the center of the cavity for symmetric coupling excitation and to ensure that the two interaction zones are in phase. The interrogation cavity has a measured resonance frequency of 6.835056471 GHz with a loaded quality factor of nearly 4200, which shows good agreement with simulation results. We measure the Rabi frequency of the clock transition of the rubidium atom in each microwave interaction zone, and subsequently demonstrate that the distributions of the magnetic field in the two interaction zones are the same and meet all requirements of the rubidium SCAC.

Chinese Physics B•Jun 1, 2016•3 citations

Accuracy of a commercial cold-atom microwave clock

Luc Archambault, Bruno Pelle, L. Lorini +3 more

•Jun 12, 2023•0 citations

Cold-Atom Clocks as Part of a Timing Ensemble

Steven Peil, J. L. Hanssen, Thomas B. Swanson +2 more

•Dec 5, 2013•0 citations

Eliminating cold-collision frequency shifts

Kurt Gibble, BOUDEWIJN J. VERHAAR

A technique to cancel the frequency shift due to cold collisions of laser-cooled atoms is proposed. Results for future clocks based on $^{135}\mathrm{Cs}$ and $^{137}\mathrm{Cs}$ are presented. We find a $^{137}\mathrm{Cs}$ fountain clock can be operated with no cold-collision shift by adjusting the population ratios in the fountain, and it may also be possible for $^{135}\mathrm{Cs}$. This technique can also be applied to other phase-sensitive measurements using cold atoms, including atom interferometers.

Physical Review A•Oct 1, 1995•57 citations
The performance of space cold atom clocks (SCACs) should be improved thanks to the microgravity environment in space. The microwave interrogation cavity is a key element in a SCAC. In this paper, we develop a microwave interrogation cavity especially for the rubidium SCAC. The interrogation cavity has two microwave interaction zones with a single feed-in source, which is located at the center of the cavity for symmetric coupling excitation and to ensure that the two interaction zones are in phase. The interrogation cavity has a measured resonance frequency of 6.835056471 GHz with a loaded quality factor of nearly 4200, which shows good agreement with simulation results. We measure the Rabi frequency of the clock transition of the rubidium atom in each microwave interaction zone, and subsequently demonstrate that the distributions of the magnetic field in the two interaction zones are the same and meet all requirements of the rubidium SCAC.
A technique to cancel the frequency shift due to cold collisions of laser-cooled atoms is proposed. Results for future clocks based on 135Cs^{135}\mathrm{Cs}135Cs and 137Cs^{137}\mathrm{Cs}137Cs are presented. We find a 137Cs^{137}\mathrm{Cs}137Cs fountain clock can be operated with no cold-collision shift by adjusting the population ratios in the fountain, and it may also be possible for 135Cs^{135}\mathrm{Cs}135Cs. This technique can also be applied to other phase-sensitive measurements using cold atoms, including atom interferometers.