Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Applied Superconductivity

A Practical Two-Stage SQUID Readout Circuit Improved With Proportional Feedback Schemes

Yongliang Wang, Guofeng Zhang, Shulin Zhang, Hui Dong, Liangliang Rong, Yong Wang, Xiaoming Xie

Published Jan 29, 2020• 2 citations
Publisher

Abstract

Nonlinearity with multiple working points limits the practical applications of a two-stage superconducting quantum interference device (SQUID) readout circuit, which is promising for low-noise performance. To solve this problem, we proposed a simple two-stage SQUID readout circuit with two conventional dc SQUIDs improved with proportional feedback schemes, where transfer coefficient of the first-stage SQUID circuit is enhanced by additional positive feedback circuit; transfer characteristics of the second-stage SQUID circuit are linearized by an additional negative feedback circuit. Two proportional feedback schemes are cooperated together based on matching conditions to achieve both noise suppression and working point matching. Working principles were verified in experiment results. The overall transfer characteristics achieved have only one working point and are simply adjusted according to the voltage swing of an amplifier. Transfer coefficient of the first-stage SQUID circuit was raised up to 10 (20 dB), and the total flux noise of two-stage SQUID readout circuit was reduced below 1 μΦ0/√Hz, where Φ0= 2.07×10-15Wb. Our two-stage SQUID readout circuit is easy-to-operate and suited for high-performance practical SQUID systems.

DOI
10.1109/tasc.2020.2970230

Related papers

Continuous feedback operation of a two-stage dc SQUID system

Insik Jin, F. C. Wellstood

We report on the continuous feedback operation of a two-stage dc Superconducting Quantum Interference Device (SQUID) system in which one SQUID works as a low-noise preamplifier to read out a second low-noise sensor SQUID. We first flux-locked the readout SQUID and measured the characteristics of the sensor SQUID, including its current-voltage characteristics, current-flux characteristics, and noise spectrum. We then investigated how the two SQUIDs could work together by simultaneously flux-locking both the sensor and the readout SQUIDs. With this two-SQUID flux-locking scheme, we recovered the noise spectrum of the sensor SQUID to within 4%. We discuss how to understand and optimize the two-stage SQUID feedback system.

IEEE Transactions on Applied Superconductivity•Jun 1, 1999•3 citations

Superconducting quantum interference device readout circuit with tunable feedback polarity

Xinyu Wu, Jianshe Liu, Wei Chen

Feedback circuits, which act as functional units in superconducting quantum interference device (SQUID) readout circuits, such as positive feedback circuits for suppressing the preamplifier noise contribution or negative feedback circuits for increasing the linear flux range of SQUID, enable SQUIDs to achieve high performance in practical applications. Integrating feedback circuits with different functions into a single SQUID chip contributes to the construction of highly compact SQUID electronics. Here, we propose a SQUID readout circuit with tunable feedback polarity (TFP). The switching of the feedback polarity is easily realized by applying a control current to the superconducting switches integrated into the SQUID chip. The enhancement of the flux-to-voltage transfer coefficient or the linear flux range depends on the choice of feedback polarity. In addition, we introduce a two-stage scheme to address the degraded noise performance induced by negative feedback. This work attempts to develop a compact and versatile architecture of SQUID readout by using a set of compatible superconducting technologies.

Review of Scientific Instruments•Sep 1, 2023•1 citation

Low-noise SQUIDs with large transfer - two stage SQUIDs based on DROSs

M. Podt, Jakob Flokstra, Horst Rogalla

We have realized a two-stage integrated superconducting quantum interference device (SQUID) system with a closed loop bandwidth of 2.5 MHz, operated in a direct voltage readout mode. The corresponding flux slew rate was 1.3×105 Φ0/s and the measured white flux noise was 1.3 μΦ0/√Hz at 4.2 K. The system is based on a conventional dc SQUID with a double relaxation oscillation SQUID (DROS) as the second stage. Because of the large flux-to-voltage transfer, the sensitivity of the system is completely determined by the sensor SQUID and not by the DROS or the room-temperature preamplifier. Decreasing the Josephson junction area enables a further improvement of the sensitivity of the two-stage SQUID systems.

•Aug 26, 2001•0 citations

Two-stage amplifier based on a double relaxation oscillation superconducting quantum interference device

M. Podt, Michiel J. van Duuren, A.W. Hamster +2 more

A low-noise single-chip two-stage superconducting quantum interference device (SQUID) system with a double relaxation oscillation SQUID as the second stage has been realized. The system was operated in a direct voltage readout mode, with a closed loop bandwidth up to 1 MHz. Operated at 4.2 K, the white flux noise measured in flux locked loop was 1.3 μΦ0/√Hz, corresponding to an energy sensitivity of ε≈27h. Owing to the large flux-to-voltage transfer of up to 3.6 mV/Φ0, the room-temperature preamplifier noise did not dominate the overall flux noise.

Applied Physics Letters•Oct 11, 1999•25 citations

Development of low-noise two-stage dc-SQUID for TES detector readout

Nan Li, Mengjie Song, Sixiao Hu +9 more

Abstract Direct-current superconducting quantum interference devices (dc-SQUIDs) are one of the most sensitive magnetic detectors. These sensors are extensively used in the readout of superconducting transition edge sensors (TESs), which are used for the detection of weak signals. A cosmic microwave background (CMB) polarization telescope operating in 22–48 GHz is currently under developing. The TESs calorimeter of the telescope will be readout by a time-division multiplexer SQUID readout system. We develop a two-stage dc-SQUID amplifier circuit, comprising an input-stage SQUID with 4 SQUID cells and a series SQUID array with 100 SQUID cells. This configuration has been shown to achieve extremely high signal gain while effectively controlling system noise. We assess the system noise at 300 mK in an adiabatic demagnetization refrigerator. The measured magnetic flux noise of the two-stage SQUID circuit system is approximately 0.3 μ Φ 0 / Hz at 10 kHz. The current noise equivalent to the input coil of input SQUID is about 2.4 pA / Hz . This result meets the low-noise readout requirements of the CMB TES and other applications with TES detectors.

arXiv:2601.19565•Superconductor Science and Technology•Apr 1, 2026•0 citations

Low-noise ultra-high-speed dc SQUID readout electronics

D. Drung, Colmar Hinnrichs, H.-J. Barthelmess

User-friendly ultra-high-speed readout electronics for dc superconducting quantum interference devices (SQUIDs) are presented. To maximize the system bandwidth, the SQUID is directly read out without flux modulation. A composite preamplifier is used consisting of a slow dc amplifier in parallel with a fast ac amplifier. In this way, excellent dc precision and a high amplifier bandwidth of 50 MHz are achieved, simultaneously. A virtual 50 Ω amplifier input resistance with negligible excess noise is realized by active shunting, i.e., by applying feedback from preamplifier output to input via a high resistance. The white voltage and current noise levels are 0.33 nV Hz −1 and 2.6 pA Hz −1/2 , respectively. The electronics is fully computer controlled via a microcontroller integrated into the flux-locked loop (FLL) board. Easy-to-use software makes the various electronic settings accessible. A wide bias voltage range of 1.3 mV enables the readout of series SQUID arrays. Furthermore, additional current sources allow the operation of two-stage SQUIDs or transition edge sensors. The electronics was tested using various SQUIDs with input inductances between 30 nH and 1.5 µH. Typically, the maximum FLL bandwidth was 20 MHz, which is close to the theoretical limit given by transmission line delay within the FLL. Slew rates of up to 4.6 Φ 0 µs −1 were achieved with series SQUID arrays. Current noise levels as low as 0.47 pA Hz −1/2 and coupled energy sensitivities between 90 h and 500 h were measured at 4.2 K, where h is the Planck constant. The noise did not degrade when the system bandwidth was increased to the maximum value of about 20 MHz. With a two-stage set-up, intrinsic white energy sensitivities of 30 h and 2.3 h were measured at 4.2 and 0.3 K, respectively.

Superconductor Science and Technology•Feb 27, 2006•76 citations
Nonlinearity with multiple working points limits the practical applications of a two-stage superconducting quantum interference device (SQUID) readout circuit, which is promising for low-noise performance. To solve this problem, we proposed a simple two-stage SQUID readout circuit with two conventional dc SQUIDs improved with proportional feedback schemes, where transfer coefficient of the first-stage SQUID circuit is enhanced by additional positive feedback circuit; transfer characteristics of the second-stage SQUID circuit are linearized by an additional negative feedback circuit. Two proportional feedback schemes are cooperated together based on matching conditions to achieve both noise suppression and working point matching. Working principles were verified in experiment results. The overall transfer characteristics achieved have only one working point and are simply adjusted according to the voltage swing of an amplifier. Transfer coefficient of the first-stage SQUID circuit was raised up to 10 (20 dB), and the total flux noise of two-stage SQUID readout circuit was reduced below 1 μΦ0/√Hz, where Φ0= 2.07×10-15Wb. Our two-stage SQUID readout circuit is easy-to-operate and suited for high-performance practical SQUID systems.
We report on the continuous feedback operation of a two-stage dc Superconducting Quantum Interference Device (SQUID) system in which one SQUID works as a low-noise preamplifier to read out a second low-noise sensor SQUID. We first flux-locked the readout SQUID and measured the characteristics of the sensor SQUID, including its current-voltage characteristics, current-flux characteristics, and noise spectrum. We then investigated how the two SQUIDs could work together by simultaneously flux-locking both the sensor and the readout SQUIDs. With this two-SQUID flux-locking scheme, we recovered the noise spectrum of the sensor SQUID to within 4%. We discuss how to understand and optimize the two-stage SQUID feedback system.
Feedback circuits, which act as functional units in superconducting quantum interference device (SQUID) readout circuits, such as positive feedback circuits for suppressing the preamplifier noise contribution or negative feedback circuits for increasing the linear flux range of SQUID, enable SQUIDs to achieve high performance in practical applications. Integrating feedback circuits with different functions into a single SQUID chip contributes to the construction of highly compact SQUID electronics. Here, we propose a SQUID readout circuit with tunable feedback polarity (TFP). The switching of the feedback polarity is easily realized by applying a control current to the superconducting switches integrated into the SQUID chip. The enhancement of the flux-to-voltage transfer coefficient or the linear flux range depends on the choice of feedback polarity. In addition, we introduce a two-stage scheme to address the degraded noise performance induced by negative feedback. This work attempts to develop a compact and versatile architecture of SQUID readout by using a set of compatible superconducting technologies.
We have realized a two-stage integrated superconducting quantum interference device (SQUID) system with a closed loop bandwidth of 2.5 MHz, operated in a direct voltage readout mode. The corresponding flux slew rate was 1.3×105 Φ0/s and the measured white flux noise was 1.3 μΦ0/√Hz at 4.2 K. The system is based on a conventional dc SQUID with a double relaxation oscillation SQUID (DROS) as the second stage. Because of the large flux-to-voltage transfer, the sensitivity of the system is completely determined by the sensor SQUID and not by the DROS or the room-temperature preamplifier. Decreasing the Josephson junction area enables a further improvement of the sensitivity of the two-stage SQUID systems.
A low-noise single-chip two-stage superconducting quantum interference device (SQUID) system with a double relaxation oscillation SQUID as the second stage has been realized. The system was operated in a direct voltage readout mode, with a closed loop bandwidth up to 1 MHz. Operated at 4.2 K, the white flux noise measured in flux locked loop was 1.3 μΦ0/√Hz, corresponding to an energy sensitivity of ε≈27h. Owing to the large flux-to-voltage transfer of up to 3.6 mV/Φ0, the room-temperature preamplifier noise did not dominate the overall flux noise.
Abstract Direct-current superconducting quantum interference devices (dc-SQUIDs) are one of the most sensitive magnetic detectors. These sensors are extensively used in the readout of superconducting transition edge sensors (TESs), which are used for the detection of weak signals. A cosmic microwave background (CMB) polarization telescope operating in 22–48 GHz is currently under developing. The TESs calorimeter of the telescope will be readout by a time-division multiplexer SQUID readout system. We develop a two-stage dc-SQUID amplifier circuit, comprising an input-stage SQUID with 4 SQUID cells and a series SQUID array with 100 SQUID cells. This configuration has been shown to achieve extremely high signal gain while effectively controlling system noise. We assess the system noise at 300 mK in an adiabatic demagnetization refrigerator. The measured magnetic flux noise of the two-stage SQUID circuit system is approximately 0.3 μ Φ 0 / Hz at 10 kHz. The current noise equivalent to the input coil of input SQUID is about 2.4 pA / Hz . This result meets the low-noise readout requirements of the CMB TES and other applications with TES detectors.
User-friendly ultra-high-speed readout electronics for dc superconducting quantum interference devices (SQUIDs) are presented. To maximize the system bandwidth, the SQUID is directly read out without flux modulation. A composite preamplifier is used consisting of a slow dc amplifier in parallel with a fast ac amplifier. In this way, excellent dc precision and a high amplifier bandwidth of 50 MHz are achieved, simultaneously. A virtual 50 Ω amplifier input resistance with negligible excess noise is realized by active shunting, i.e., by applying feedback from preamplifier output to input via a high resistance. The white voltage and current noise levels are 0.33 nV Hz −1 and 2.6 pA Hz −1/2 , respectively. The electronics is fully computer controlled via a microcontroller integrated into the flux-locked loop (FLL) board. Easy-to-use software makes the various electronic settings accessible. A wide bias voltage range of 1.3 mV enables the readout of series SQUID arrays. Furthermore, additional current sources allow the operation of two-stage SQUIDs or transition edge sensors. The electronics was tested using various SQUIDs with input inductances between 30 nH and 1.5 µH. Typically, the maximum FLL bandwidth was 20 MHz, which is close to the theoretical limit given by transmission line delay within the FLL. Slew rates of up to 4.6 Φ 0 µs −1 were achieved with series SQUID arrays. Current noise levels as low as 0.47 pA Hz −1/2 and coupled energy sensitivities between 90 h and 500 h were measured at 4.2 K, where h is the Planck constant. The noise did not degrade when the system bandwidth was increased to the maximum value of about 20 MHz. With a two-stage set-up, intrinsic white energy sensitivities of 30 h and 2.3 h were measured at 4.2 and 0.3 K, respectively.