Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Development and Characterization of a Ytterbium-171 Miniature Ion Trap Frequency Standard

Heather L. Partner

Published Jan 1, 2012• 0 citations
OpenAlex

Related papers

Miniature trapped-ion frequency standard with 171Yb+; Proceedings.

Peter D. D. Schwindt, Yuan‐Yu Jau, Heather L. Partner +14 more

•Apr 1, 2015•0 citations

Miniature trapped-ion frequency standard with 171Yb+.

Peter D. D. Schwindt

•May 4, 2016•5 citations

Towards a Microwave-Laser Double Resonance Passive Frequency Standard Using Trapped Ytterbium Ions.

David J. Seidel

•Jan 1, 1995•0 citations

Implementation of an Ytterbium 171 Trapped Ion Qubit

Naleli Jubert Matjelo

•Apr 1, 2020•1 citation

Micro Ion Frequency Standard

Peter D. D. Schwindt, Roy H. Olsson, K.E. Wojciechowski +7 more

We are developing a highly miniaturized trapped ion clock to probe the 12.6 GHz hyperfine transition in the 171 Yb + ion. The clock development is being funded by the Integrated Micro Primary Atomic Clock Technology (IMPACT)program from DARPA where the stated goals are to develop a clock that consumes 50 mW of power, has a size of 5 cm 3 , and has a long-term frequency stability of 10 -14 at one month.Trapped ion systems are an excellent candidate for such extreme miniaturization because ions are well isolated from the environment independent of the size of the trap.Trapped ion clocks are characterized by quality factors, Q, in excess of 10 12 and excellent long-term stability, and the Q will be minimally degraded upon miniaturization.To realize the clock in a small package will require the miniaturization of several technologies.One of the primary technologies will be the miniaturized ion trap and vacuum package.Linear RF Paul traps routinely have dimensions of a couple millimeters but miniaturizing the vacuum package with an integral trap, Yb source, and pump will require a novel design.Integrating the miniature, low-power light sources for state detection at 369 nm and 935 nm and for photoionization at 399 nm will also be critical.The 369 nm laser will be a frequency doubled vertical external cavity surface emitting laser (VECSEL).A low-phase-noise local oscillator at 12.6 GHz will also be developed using a micro resonator based on exciting acoustic resonances in aluminum nitride.We will present our proposed approach to developing the micro ion frequency standard and relevant current results.

•Nov 19, 2009•2 citations

Portable, laser-cooled ytterbium ion frequency standard

Sean Mulholland, Hugh A. Klein, G. P. Barwood +6 more

We report on the development of a portable, trapped-ion, microwave frequency standard based on the 12.6 GHz hyperfine transition in laser-cooled ytterbium-171 ions. The entire system fits into a 6U 19-inch rack unit ($51\times49\times28$ cm) and comprises laser, electronics and physics package subsystems. The performance of this development system is evaluated; the fractional frequency instability was measured to be $3.6\times10^{-12}/\surd\tau$ for averaging times between 30 s and 1500 s.

•Nov 15, 2018•1 citation
We are developing a highly miniaturized trapped ion clock to probe the 12.6 GHz hyperfine transition in the 171 Yb + ion. The clock development is being funded by the Integrated Micro Primary Atomic Clock Technology (IMPACT)program from DARPA where the stated goals are to develop a clock that consumes 50 mW of power, has a size of 5 cm 3 , and has a long-term frequency stability of 10 -14 at one month.Trapped ion systems are an excellent candidate for such extreme miniaturization because ions are well isolated from the environment independent of the size of the trap.Trapped ion clocks are characterized by quality factors, Q, in excess of 10 12 and excellent long-term stability, and the Q will be minimally degraded upon miniaturization.To realize the clock in a small package will require the miniaturization of several technologies.One of the primary technologies will be the miniaturized ion trap and vacuum package.Linear RF Paul traps routinely have dimensions of a couple millimeters but miniaturizing the vacuum package with an integral trap, Yb source, and pump will require a novel design.Integrating the miniature, low-power light sources for state detection at 369 nm and 935 nm and for photoionization at 399 nm will also be critical.The 369 nm laser will be a frequency doubled vertical external cavity surface emitting laser (VECSEL).A low-phase-noise local oscillator at 12.6 GHz will also be developed using a micro resonator based on exciting acoustic resonances in aluminum nitride.We will present our proposed approach to developing the micro ion frequency standard and relevant current results.
We report on the development of a portable, trapped-ion, microwave frequency standard based on the 12.6 GHz hyperfine transition in laser-cooled ytterbium-171 ions. The entire system fits into a 6U 19-inch rack unit (51×49×2851\times49\times2851×49×28 cm) and comprises laser, electronics and physics package subsystems. The performance of this development system is evaluated; the fractional frequency instability was measured to be 3.6×10−12/√τ3.6\times10^{-12}/\surd\tau3.6×10−12/√τ for averaging times between 30 s and 1500 s.