Time-reversed quantum trajectories are defined for a thermally pumped micromaser for atom arrivals modelled as a renewal process. They are shown to arise naturally in the derivation of an equality between atomic beam and cavity field correlations, and are used to obtain Crooks fluctuation relations for entropy flow.
Abstract The micromaser is examined with the aim of understanding certain of its properties based on a time-reversed quantum trajectory analysis. The background theory of master equations derived from a repeated interaction model perspective is briefly reviewed and extended by taking into account the more general renewal process description of the sequence of interactions of the system with incoming ancilla, and results compared with other recent (and not so recent) approaches that use this generalisation. The results are then specialised to the micromaser, and a quantum trajectory unravelling of the micromaser dynamics is formulated that enables time-reversed quantum trajectories, defined according to the Crooks approach, to, first, be shown to arise naturally in the analysis of micromaser and atomic beam correlations, and second used in the formulation of a fluctuation relation for the probabilities of trajectories and their time-reversed counterparts.
In this paper results are reported for the application of the quantum trajectory method to analysing the dynamics of the micromaser. The master equation for the cavity field is derived by a method which highlights the close relationship between the quantum trajectory method and the usual model for the one-atom micromaser. Possible quantum trajectory unravellings of the micromaser dynamics are discussed, and a simple number-state unravelling is described and used to generate simulations from which the cavity-field intensity correlation function is calculated. Attention is principally confined to the case of a Poissonian atomic beam, though a method of dealing with the non-Markovian master equation obtained for non-Poissonian beams is also examined. A formal theory of atomic detection analogous to the Glauber - Kelly - Kleiner theory of photodetection is proposed, based on a quantum-field description of the atomic beam. This theory is used to establish the connection between the atomic detection record obtained by continuous monitoring of the atoms leaving the cavity and the quantum trajectories followed by the cavity field. Results obtained by other treatments of atomic detection are regained. A classical correlation function obtained from the detection record of ground-state atoms emerging from a micromaser cavity is then shown, by use of a quantum trajectory analysis, to be identical to the cavity field intensity correlation function, apart from shot-noise-type contributions, provided the cavity reservoir is at zero temperature.
We study the dynamics of the single-atom maser, or micromaser, by means of the recently introduced method of thermodynamics of quantum jump trajectories. We find that the dynamics of the micromaser displays multiple space-time phase transitions, i.e., phase transitions in ensembles of quantum jump trajectories. This rich dynamical phase structure becomes apparent when trajectories are classified by dynamical observables that quantify dynamical activity, such as the number of atoms that have changed state while traversing the cavity. The space-time transitions can be either first order or continuous, and are controlled not just by standard parameters of the micromaser but also by nonequilibrium "counting" fields. We discuss how the dynamical phase behavior relates to the better known stationary-state properties of the micromaser.
By applying a quantum-trajectory approach to a master equation for the cavity mode density operator, we investigate the dynamics and the trapping states of a micromaser or microlaser including the effects of cavity temperature, two-atom events, atomic velocity spread, and partial excitation of the atomic beam. In the description of two-atom collective effects we allow for the nonsimultaneous arrival of atoms in the cavity, generalizing to a mean number of atoms ${N}_{\mathrm{at}}\ensuremath{\approx}1,$ a recent treatment [M. I. Kolobov and F. Haake, Phys. Rev. A 55, 3033 (1997)]. We show that, in trapping regions, our treatment of two-atom events can give strikingly different effects with respect to the approximation of simultaneous arrival of atom pairs; e.g., detrapping instead of trapping, different times of approach to the steady state, and different photonstatistics. Also, we simulate micromaser dynamics with parameter values corresponding to the recent experimental observation of the trapping effect by Walther and collaborators [H. Weidinger et al., Technical Digest of the European Quantum Electronics Conference '98 (IEEE, Piscataway, NJ, 1998)].
We present a quantum theory of the micromaser which allows for arbitrary (sub- as well as super-Poissonian) fluctuations of the pumping beam. It handles the interaction with the active atoms (gain) and cavity decay (loss) on an equal footing. In conventional reservoir theory the rate of change of the cavity field is a sum of the changes due to separate interactions with the individual reservoirs, i.e., the interactions are uncorrelated. In our approach, corrections to reservoir theory arise. They contain the commutator of the gain and loss operators. The magnitude of these additional terms is characterized by the quantity p/Nex where p is a parameter describing pump-beam fluctuations. The parameter is, in fact, the negative of the Mandel Q parameter of the pump beam so that p=1 corresponds to regular pumping, p=0 to Poissonian one and p0 to super-Poissonian pump beam fluctuations. Nex is the number of excited atoms passing through the cavity during the lifetime of the intracavity field. Thus we recover the conventional reservoir limit if p=0 and/or Nex is large. In all other cases the interactions with the gain and loss reservoirs are correlated. We exploit some of the consequences of the additional terms, presenting analytical as well as numerical results for the steady-state photon statistics (mean photon number and photon-number fluctuations, in particular) without resorting to the p expansion.
A method is presented for theoretically investigating the properties of a one-atom micromaser with stationary non-Poissonian pumping. The method is based on treating the statistics of the arrival times of the individual pump atoms with the help of the theory of stochastic point processes. Considerable simplification is achieved by assuming the pump statistics to be described by a stationary renewal process. Thus the influence of super- as well as sub-Poissonian pumping with different strengths of correlation between the pump atoms and different correlation decay times may be studied quantitatively. The level-selective statistics of the atoms leaving the cavity is investigated as well as the photon statistics of the cavity field. Moreover, the relation to the other models used in the literature for describing the micromaser pump statistics is discussed. It is found that for sub- (super-)Poissonian pumping, the stationary expectation value of the cavity photon number (which corresponds to its time-averaged value) is larger (smaller) than the conditioned mean photon number that would result from averaging over the number of photons present in the cavity at the time instants immediately before the injection of the individual pump atoms. For Poissonian pumping, both quantities are shown to be equal. The relative standard deviation of the stationary cavity photon number is decreased (increased) for sub- (super-) Poissonian pumping, in comparison to the corresponding values that would result from Poissonian pumping. Moreover, it turns out that for sub- (super-)Poissonian pumping, the normalized coincidence probability density for the detection of the outgoing deexcited atoms is smaller (larger) than the normalized cavity field intensity correlation function at zero time delay. The difference decreases with increasing lifetime of the pump-atom correlations. Finally, the level-selective delayed coincidence probability densities of the outgoing atoms and their waiting-time distributions are found to be affected greatly by the correlation strength as well as the correlation decay time of the incoming pump atoms.