Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Investigations on Microwave Power Shift in Compact Vapor-Cell Atomic Clock

William Moreno, Matthieu Pellaton, Nil Almat, Mohammadreza Gharavipour, C. Affolderbach, G. Mileti

Published Apr 1, 2019• 2 citations
Publisher

Abstract

We employ a three-level Bloch vector model to simulate Ramsey fringes of our Rb vapor-cell atomic clock. The residual inhomogeneity of the microwave magnetic field across the buffer-gas cell is a key ingredient for correctly modelling the behavior at high microwave powers (pulse area > π/2. We add to this model different position-dependent frequency shifts that arise from external fields, and we identify inhomogeneous light-shifts as the dominant contribution for reproducing the measured clock frequency shifts as a function of microwave power. Other frequency shifts give negligible contributions.

DOI
10.1109/fcs.2019.8856053

Related papers

Imaging Microwave and DC Magnetic Fields in a Vapor-Cell Rb Atomic Clock

C. Affolderbach, Guanxiang Du, Thejesh Bandi +3 more

We report on the experimental measurement of the dc and microwave magnetic field distributions inside a recently developed compact magnetron-type microwave cavity mounted inside the physics package of a high-performance vapor-cell atomic frequency standard. Images of the microwave field distribution with sub-100-μm lateral spatial resolution are obtained by pulsed optical-microwave Rabi measurements, using the Rb atoms inside the cell as field probes and detecting with a CCD camera. Asymmetries observed in the microwave field images can be attributed to the precise practical realization of the cavity and the Rb vapor cell. Similar spatially resolved images of the dc magnetic field distribution are obtained by Ramsey-type measurements. The T2relaxation time in the Rb vapor cell is found to be position dependent and correlates with the gradient of the dc magnetic field. The presented method is highly useful for experimental in situ characterization of dc magnetic fields and resonant microwave structures, for atomic clocks or other atom-based sensors and instrumentation.

arXiv:1505.07739•IEEE Transactions on Instrumentation and Measurement•Jul 21, 2015•45 citations

Ramsey-fringe shape in an alkali-metal vapor cell with buffer gas

Salvatore Micalizio, Claudio Eligio Calosso, Filippo Levi +1 more

In this paper we describe a few phenomena that may affect the linewidth and/or the line shape of Ramsey fringes observed in an alkali-metal vapor cell with buffer gas. Experiments are performed on a vapor-cell--microwave-cavity arrangement in which ${}^{87}\mathrm{Rb}$ atoms successively experience laser pumping preparation (through a ${D}_{2}$ line), microwave interrogation with a couple of coherent pulses, and clock signal detection by means of laser absorption. We show that the linewidth of the Ramsey central fringe is influenced by the Rabi pattern produced by a single microwave pulse. Moreover, cycle memory and atomic density effects can modify the shape of the Ramsey central fringe from the common sinusoidal behavior. A simple three-level model well reproduces the experimental observations.

Physical Review A•Sep 3, 2013•15 citations

Study of additive manufactured microwave cavities for pulsed optically pumped atomic clock applications

C. Affolderbach, William Moreno, A. E. Ivanov +5 more

Additive manufacturing (AM) of passive microwave components is of high interest for the cost-effective and rapid prototyping or manufacture of devices with complex geometries. Here, we present an experimental study on the properties of recently demonstrated microwave resonator cavities manufactured by AM, in view of their applications to high-performance compact atomic clocks. The microwave cavities employ a loop-gap geometry using six electrodes. The critical electrode structures were manufactured monolithically using two different approaches: Stereolithography (SLA) of a polymer followed by metal coating and Selective Laser Melting (SLM) of aluminum. The tested microwave cavities show the desired TE011-like resonant mode at the Rb clock frequency of ≈6.835 GHz, with a microwave magnetic field highly parallel to the quantization axis across the vapor cell. When operated in an atomic clock setup, the measured atomic Rabi oscillations are comparable to those observed for conventionally manufactured cavities and indicate a good uniformity of the field amplitude across the vapor cell. Employing a time-domain Ramsey scheme on one of the SLA cavities, high-contrast (34%) Ramsey fringes are observed for the Rb clock transition, along with a narrow (166 Hz linewidth) central fringe. The measured clock stability of 2.2 × 10−13 τ−1/2 up to the integration time of 30 s is comparable to the current state-of-the-art stabilities of compact vapor-cell clocks based on conventional microwave cavities and thus demonstrates the feasibility of the approach.

Applied Physics Letters•Mar 12, 2018•23 citations

Frequency Shifts in a Coherent Population Trapping Cs Vapor Cell Atomic Clock

Juliette Breurec, Moustafa Abdel Hafiz, Claudio Eligio Calosso +2 more

We report on measurements of frequency shifts in a microwave cesium vapor cell atomic clock based on coherent population trapping (CPT). The dependence of the clock frequency on numerous experimental parameters, such as the laser power, the laser frequency, the microwave power, the cell temperature, the static magnetic field, but also the temperature of some key components, or the translation and rotation of critical wave plates and optical elements, is investigated. The stability budget of the clock frequency at one day is reported and discussed. This study constitutes a solid database for the future demonstration of a CPT-based cell clock with enhanced mid- and long-term stability performances.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•May 29, 2025•4 citations

A frequency shift compensation method for light shift and vapor-cell temperature shift in atomic clocks

Dou Li, Kangqi Liu, Linzhen Zhao +1 more

Light shift and vapor-cell temperature shift are the two most significant factors dominating the long-term instability of compact atomic clocks. Due to the different physical mechanisms, there is not yet a solution that can effectively suppress the frequency shifts induced by these two effects. Here, we propose a 'resonance-offset' locking approach that compensates for the two physical frequency shifts. In this approach, the additional offset locking shift can effectively counteract the atomic resonance shifts arising from changes in vapor-cell temperature and light power, reducing the net impact on the clock's frequency to nearly zero. We have demonstrated this strategy on the 778 nm Rubidium two-photon optical frequency standard, successfully compensating for light shift and cell-temperature shift, respectively. This general method is particularly appealing for compact vapor-cell microwave and optical atomic clocks designed for the excellent stability rather than accuracy.

arXiv:2405.14281•May 23, 2024•1 citation

Raman-Ramsey resonances in atomic vapor cells: Rabi pulling and optical-density effects

Salvatore Micalizio, Aldo Godone

Raman-Ramsey interference has proved a very effective technique to implement compact and high performing vapor cell frequency standards. In this paper, we theoretically characterize Raman-Ramsey resonances in an optically thick atomic vapor. Specifically, some parameters of interest for frequency standards applications, like contrast and linewidth of the central Raman-Ramsey fringe, are evaluated at different temperatures for $^{133}\mathrm{Cs}$ and $^{87}\mathrm{Rb}$ vapor cells with buffer gas. Density narrowing and broadening effects are described and explained in terms of a three-level theory where laser field propagation through the atomic medium is taken into account. Also, we investigate light shift both in low and high atomic density regimes. Light shift, which potentially degrades the medium- to long-term stability of Raman-Ramsey clocks, is composed of two contributions. The first is a pulling effect exerted by the wide Rabi profile enclosing the interference pattern on the central Raman-Ramsey fringe. The second light-shift term is strictly related to the detection time. Calculations derived from our model well describe already existing experimental results and new behaviors are predicted.

Physical Review A•Apr 26, 2019•14 citations
We employ a three-level Bloch vector model to simulate Ramsey fringes of our Rb vapor-cell atomic clock. The residual inhomogeneity of the microwave magnetic field across the buffer-gas cell is a key ingredient for correctly modelling the behavior at high microwave powers (pulse area > π/2. We add to this model different position-dependent frequency shifts that arise from external fields, and we identify inhomogeneous light-shifts as the dominant contribution for reproducing the measured clock frequency shifts as a function of microwave power. Other frequency shifts give negligible contributions.
We report on the experimental measurement of the dc and microwave magnetic field distributions inside a recently developed compact magnetron-type microwave cavity mounted inside the physics package of a high-performance vapor-cell atomic frequency standard. Images of the microwave field distribution with sub-100-μm lateral spatial resolution are obtained by pulsed optical-microwave Rabi measurements, using the Rb atoms inside the cell as field probes and detecting with a CCD camera. Asymmetries observed in the microwave field images can be attributed to the precise practical realization of the cavity and the Rb vapor cell. Similar spatially resolved images of the dc magnetic field distribution are obtained by Ramsey-type measurements. The T2relaxation time in the Rb vapor cell is found to be position dependent and correlates with the gradient of the dc magnetic field. The presented method is highly useful for experimental in situ characterization of dc magnetic fields and resonant microwave structures, for atomic clocks or other atom-based sensors and instrumentation.
In this paper we describe a few phenomena that may affect the linewidth and/or the line shape of Ramsey fringes observed in an alkali-metal vapor cell with buffer gas. Experiments are performed on a vapor-cell--microwave-cavity arrangement in which 87Rb{}^{87}\mathrm{Rb}87Rb atoms successively experience laser pumping preparation (through a D2{D}_{2}D2​ line), microwave interrogation with a couple of coherent pulses, and clock signal detection by means of laser absorption. We show that the linewidth of the Ramsey central fringe is influenced by the Rabi pattern produced by a single microwave pulse. Moreover, cycle memory and atomic density effects can modify the shape of the Ramsey central fringe from the common sinusoidal behavior. A simple three-level model well reproduces the experimental observations.
Additive manufacturing (AM) of passive microwave components is of high interest for the cost-effective and rapid prototyping or manufacture of devices with complex geometries. Here, we present an experimental study on the properties of recently demonstrated microwave resonator cavities manufactured by AM, in view of their applications to high-performance compact atomic clocks. The microwave cavities employ a loop-gap geometry using six electrodes. The critical electrode structures were manufactured monolithically using two different approaches: Stereolithography (SLA) of a polymer followed by metal coating and Selective Laser Melting (SLM) of aluminum. The tested microwave cavities show the desired TE011-like resonant mode at the Rb clock frequency of ≈6.835 GHz, with a microwave magnetic field highly parallel to the quantization axis across the vapor cell. When operated in an atomic clock setup, the measured atomic Rabi oscillations are comparable to those observed for conventionally manufactured cavities and indicate a good uniformity of the field amplitude across the vapor cell. Employing a time-domain Ramsey scheme on one of the SLA cavities, high-contrast (34%) Ramsey fringes are observed for the Rb clock transition, along with a narrow (166 Hz linewidth) central fringe. The measured clock stability of 2.2 × 10−13 τ−1/2 up to the integration time of 30 s is comparable to the current state-of-the-art stabilities of compact vapor-cell clocks based on conventional microwave cavities and thus demonstrates the feasibility of the approach.
We report on measurements of frequency shifts in a microwave cesium vapor cell atomic clock based on coherent population trapping (CPT). The dependence of the clock frequency on numerous experimental parameters, such as the laser power, the laser frequency, the microwave power, the cell temperature, the static magnetic field, but also the temperature of some key components, or the translation and rotation of critical wave plates and optical elements, is investigated. The stability budget of the clock frequency at one day is reported and discussed. This study constitutes a solid database for the future demonstration of a CPT-based cell clock with enhanced mid- and long-term stability performances.
Light shift and vapor-cell temperature shift are the two most significant factors dominating the long-term instability of compact atomic clocks. Due to the different physical mechanisms, there is not yet a solution that can effectively suppress the frequency shifts induced by these two effects. Here, we propose a 'resonance-offset' locking approach that compensates for the two physical frequency shifts. In this approach, the additional offset locking shift can effectively counteract the atomic resonance shifts arising from changes in vapor-cell temperature and light power, reducing the net impact on the clock's frequency to nearly zero. We have demonstrated this strategy on the 778 nm Rubidium two-photon optical frequency standard, successfully compensating for light shift and cell-temperature shift, respectively. This general method is particularly appealing for compact vapor-cell microwave and optical atomic clocks designed for the excellent stability rather than accuracy.
Raman-Ramsey interference has proved a very effective technique to implement compact and high performing vapor cell frequency standards. In this paper, we theoretically characterize Raman-Ramsey resonances in an optically thick atomic vapor. Specifically, some parameters of interest for frequency standards applications, like contrast and linewidth of the central Raman-Ramsey fringe, are evaluated at different temperatures for 133Cs^{133}\mathrm{Cs}133Cs and 87Rb^{87}\mathrm{Rb}87Rb vapor cells with buffer gas. Density narrowing and broadening effects are described and explained in terms of a three-level theory where laser field propagation through the atomic medium is taken into account. Also, we investigate light shift both in low and high atomic density regimes. Light shift, which potentially degrades the medium- to long-term stability of Raman-Ramsey clocks, is composed of two contributions. The first is a pulling effect exerted by the wide Rabi profile enclosing the interference pattern on the central Raman-Ramsey fringe. The second light-shift term is strictly related to the detection time. Calculations derived from our model well describe already existing experimental results and new behaviors are predicted.