Conference on Lasers and Electro-Optics

Quantum-Enhanced Optomechanical Magnetometry

Jan Bílek, Bei‐Bei Li, Ulrich B. Hoff, Lars S. Madsen, Stefan Forstner, Varun Prakash, Clemens Schäfermeier, Tobias Gehring, Warwick P. Bowen, Ulrik L. Andersen

Published Jan 1, 2018• 1 citation
Publisher

Abstract

Quantum-enhanced measurements of magnetic fields are experimentally demonstrated using a microcavity optomechanical magnetometer and squeezed states of light. We attain an improvement of the magnetic field sensitivity of 20% using 2.2dB phase-squeezed states.
DOI
10.1364/cleo_at.2018.jth2a.25

Related papers

Precision magnetic field sensing using a cavity optomechanical system

Bei‐Bei Li, Jan Bílek, Douglas A. P. Bulla +2 more

A broad band and sensitive magnetometry has been demonstrated by integrating a magnetostrictive material with a high Q optical microcavity. We have developed a scalable fabrication method and demonstrated quantum light enhanced optomechanical magnetometry.

International Photonics and Optoelectronics Meetings•Jan 1, 2019•3 citations

Experimental light-squeezing-enhanced magnetometry

Alessandro Ceré, Florian Wolfgramm, Federica A. Beduini +3 more

The ability to measure magnetic fields with high sensitivity is a key requirement in many physical, biological and medical applications. Currently the most sensitive magnetometers are optical magnetometers, in which the polarization of an atomic sample responds to the field and is read out by an optical measurement. These instruments are limited by two fundamental sources of quantum noise: projection noise of the atoms and shot noise of the light. For magnetometers designed to have a high statistical sensitivity, contributions from both sources are comparable. Here we show that the sensitivity can be improved by the application of non-classical light.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•May 1, 2011•0 citations

Quantum Magnetometer with Dual‐Coupling Optomechanics

Gui‐Lei Zhu, Jing Liu, Ying Wu +1 more

Abstract An experimentally feasible magnetometer based on a dual‐coupling optomechanical system is proposed, where the radiation‐pressure coupling transduces the magnetic signal to the optical phase, and the quadratic optomechanical interaction induces a periodic squeezing effect. The latter not only amplifies the signal to be measured, but also accelerates the signal transducing rate characterized by an experimentally observable phase accumulation efficiency. In the vicinity of opto‐mechanical decoupled time, the ultimate bound to the estimability of magnetic signal is proportional to , and then the optimized accuracy of estimation can be enhanced nearly three orders with a controllable squeezing parameter . Moreover, this proposal is robust against the mechanical thermal noise, and the sensitivity of a specific measurement can reach to the order of in the presence of dissipations and without ground state cooling of mechanical oscillator. The proposal fundamentally broadens the fields of quantum metrology and cavity optomechanics, with the potential application for on‐chip magnetic detection with high precision.

arXiv:2205.00433•Laser & Photonics Review•Jul 1, 2022•13 citations

Improving sensitivity of an amplitude-modulated magneto-optical atomic magnetometer using squeezed light

Jiahui Li, Irina V. Novikova

We experimentally demonstrate that a squeezed probe optical field can improve the sensitivity of magnetic field measurements based on nonlinear magneto-optical rotation (NMOR) with an amplitude-modulated pump when compared to a coherent probe field under identical conditions. To realize an all-atomic magnetometer prototype, we utilize a nonlinear atomic interaction, known as polarization self-rotation, to produce a squeezed probe field. An independent pump field, amplitude-modulated at the Larmor frequency of the bias magnetic field, allows us to extend the range of most sensitive NMOR measurements to sub-Gauss magnetic fields. While the overall sensitivity of the magnetometer is rather low ( > 250 p T / H z ), we clearly observe a 15 % sensitivity improvement when the squeezed probe is used. Our observations confirm the recently reported quantum enhancement in a modulated atomic magnetometer [ Phys. Rev. Lett. 127 , 193601 ( 2021 ) PRLTAO 0031-9007 10.1103/PhysRevLett.127.193601 ].

arXiv:2207.12962•Journal of the Optical Society of America B•Oct 5, 2022•15 citations

Squeezed light enhanced sensing of a micro-mechanical oscillator (Conference Presentation)

Ulrik L. Andersen

Ultra-precise measurements of various parameters such as the mass of nano-particles, magnetic fields or gravity can be attained by probing the phononic modes of a micro-mechanical oscillator with light. The sensitivity of such measurements is in part governed by the noise of the phononic mode as well as the noise of the probing light mode, so by decreasing the noise of the probe beam an enhanced sensitivity can be expected. We demonstrate this effect by using squeezed states of light where the quantum uncertainty of the relevant quadrature is reduced below the shot noise level. Using this squeezing-enhanced sensitivity effect, we demonstrate 1) improved feedback cooling of a phononic mode in a microtoroidal cavity and 2) improved sensing of a magnetic field using the coupling to a microtoroidal phononic mode via a magnetorestrictive material. We present our recent experimental results and discuss future directions.

Quantum Communications and Quantum Imaging•Sep 19, 2017•0 citations

Quantum-Light-Enhanced Optical Magnetometry

Florian Wolfgramm, Alessandro Ceré, Yannick A. de Icaza Astiz +4 more

We demonstrate a light-shot-noise limited magnetometer based on the Faraday effect in a hot unpolarized ensemble of rubidium atoms. By using off-resonant, polarization-squeezed probe light, we improve the sensitivity of the magnetometer by 3.2 dB.

•Jan 1, 2011•0 citations
The ability to measure magnetic fields with high sensitivity is a key requirement in many physical, biological and medical applications. Currently the most sensitive magnetometers are optical magnetometers, in which the polarization of an atomic sample responds to the field and is read out by an optical measurement. These instruments are limited by two fundamental sources of quantum noise: projection noise of the atoms and shot noise of the light. For magnetometers designed to have a high statistical sensitivity, contributions from both sources are comparable. Here we show that the sensitivity can be improved by the application of non-classical light.
Abstract An experimentally feasible magnetometer based on a dual‐coupling optomechanical system is proposed, where the radiation‐pressure coupling transduces the magnetic signal to the optical phase, and the quadratic optomechanical interaction induces a periodic squeezing effect. The latter not only amplifies the signal to be measured, but also accelerates the signal transducing rate characterized by an experimentally observable phase accumulation efficiency. In the vicinity of opto‐mechanical decoupled time, the ultimate bound to the estimability of magnetic signal is proportional to , and then the optimized accuracy of estimation can be enhanced nearly three orders with a controllable squeezing parameter . Moreover, this proposal is robust against the mechanical thermal noise, and the sensitivity of a specific measurement can reach to the order of in the presence of dissipations and without ground state cooling of mechanical oscillator. The proposal fundamentally broadens the fields of quantum metrology and cavity optomechanics, with the potential application for on‐chip magnetic detection with high precision.
We experimentally demonstrate that a squeezed probe optical field can improve the sensitivity of magnetic field measurements based on nonlinear magneto-optical rotation (NMOR) with an amplitude-modulated pump when compared to a coherent probe field under identical conditions. To realize an all-atomic magnetometer prototype, we utilize a nonlinear atomic interaction, known as polarization self-rotation, to produce a squeezed probe field. An independent pump field, amplitude-modulated at the Larmor frequency of the bias magnetic field, allows us to extend the range of most sensitive NMOR measurements to sub-Gauss magnetic fields. While the overall sensitivity of the magnetometer is rather low ( > 250 p T / H z ), we clearly observe a 15 % sensitivity improvement when the squeezed probe is used. Our observations confirm the recently reported quantum enhancement in a modulated atomic magnetometer [ Phys. Rev. Lett. 127 , 193601 ( 2021 ) PRLTAO 0031-9007 10.1103/PhysRevLett.127.193601 ].
Ultra-precise measurements of various parameters such as the mass of nano-particles, magnetic fields or gravity can be attained by probing the phononic modes of a micro-mechanical oscillator with light. The sensitivity of such measurements is in part governed by the noise of the phononic mode as well as the noise of the probing light mode, so by decreasing the noise of the probe beam an enhanced sensitivity can be expected. We demonstrate this effect by using squeezed states of light where the quantum uncertainty of the relevant quadrature is reduced below the shot noise level. Using this squeezing-enhanced sensitivity effect, we demonstrate 1) improved feedback cooling of a phononic mode in a microtoroidal cavity and 2) improved sensing of a magnetic field using the coupling to a microtoroidal phononic mode via a magnetorestrictive material. We present our recent experimental results and discuss future directions.