Bulletin of the American Physical Society

Investigation of low-outgassing lithium sources for a portable cold-atom vacuum standard

Eric B. Norrgard, Daniel S. Barker, James A. Fedchak, Nikolai N. Klimov, Julia K. Scherschligt, Stephen Eckel

Published May 31, 2018• 0 citations
OpenAlex

Related papers

Progress toward a cold-atom based vacuum standard and pressure gauge

Stephen Eckel, Daniel S. Barker, James A. Fedchak +3 more

Bulletin of the American Physical Society•Jun 2, 2020•0 citations

Comparison of two multiplexed portable cold-atom vacuum standards

L. Ehinger, B. P. Acharya, Daniel S. Barker +4 more

We compare the vacuum measured by two portable cold-atom vacuum standards (pCAVSs) based on ultracold 7Li atoms. pCAVSs are quantum-based standards that use a priori scattering calculations to convert a measured loss rate of cold atoms from a conservative trap into a background gas pressure. Our pCAVS devices share the same laser system and measure the vacuum concurrently. The two pCAVSs together detected a leak with a rate on the order of 10−6 Pa l/s. After fixing the leak, the pCAVS measured pressure of about 40 nPa with 2.6% uncertainty. The two pCAVSs agree within their uncertainties, even when swapping some of their component parts. Operation of the pCAVS was found to cause some additional outgassing, on the order of 10−8 Pa l/s, which can be mitigated in the future by better thermal management.

arXiv:2204.03705•AVS Quantum Science•Jul 15, 2022•25 citations

Electron impact ionization studies with trapped lithium atoms

Ming-Tie Huang, Liang Zhang, Sunao Hasegawa +3 more

APS•May 1, 2002•0 citations

Precise quantum measurement of vacuum with cold atoms

Daniel S. Barker, B. P. Acharya, James A. Fedchak +5 more

We describe the cold-atom vacuum standards (CAVS) under development at the National Institute of Standards and Technology (NIST). The CAVS measures pressure in the ultra-high and extreme-high vacuum regimes by measuring the loss rate of sub-millikelvin sensor atoms from a magnetic trap. Ab initio quantum scattering calculations of cross sections and rate coefficients relate the density of background gas molecules or atoms to the loss rate of ultra-cold sensor atoms. The resulting measurement of pressure through the ideal gas law is traceable to the second and the kelvin, making it a primary realization of the pascal. At NIST, two versions of the CAVS have been constructed: a laboratory standard used to achieve the lowest possible uncertainties and pressures, and a portable version that is a potential replacement for the Bayard-Alpert ionization gauge. Both types of CAVSs are connected to a combined extreme-high vacuum flowmeter and dynamic expansion system to enable sensing of a known pressure of gas. In the near future, we anticipate being able to compare the laboratory scale CAVS, the portable CAVS, and the flowmeter/dynamic expansion system to validate the operation of the CAVS as both a standard and vacuum gauge.

Review of Scientific Instruments•Dec 1, 2022•18 citations

Measurement of vacuum pressure with a magneto-optical trap: A pressure-rise method

R. Moore, Lucie A. Lee, Elizabeth A. Findlay +3 more

The lifetime of an atom trap is often limited by the presence of residual background gases in the vacuum chamber. This leads to the lifetime being inversely proportional to the pressure. Here, we use this dependence to estimate the pressure and to obtain pressure rate-of-rise curves, which are commonly used in vacuum science to evaluate the performance of a system. We observe different rates of pressure increase in response to different levels of outgassing in our system. Therefore, we suggest that this is a sensitive method which will find useful applications in cold atom systems, in particular, where the inclusion of a standard vacuum gauge is impractical.

arXiv:1401.7949•Review of Scientific Instruments•Sep 1, 2015•41 citations

Apparatus for creating quantum degenerate gas of Lithium-6

Vinod Gaire, Levi Salyards, Cameron Caligan +1 more

Bulletin of the American Physical Society•Jun 8, 2017•0 citations
We compare the vacuum measured by two portable cold-atom vacuum standards (pCAVSs) based on ultracold 7Li atoms. pCAVSs are quantum-based standards that use a priori scattering calculations to convert a measured loss rate of cold atoms from a conservative trap into a background gas pressure. Our pCAVS devices share the same laser system and measure the vacuum concurrently. The two pCAVSs together detected a leak with a rate on the order of 10−6 Pa l/s. After fixing the leak, the pCAVS measured pressure of about 40 nPa with 2.6% uncertainty. The two pCAVSs agree within their uncertainties, even when swapping some of their component parts. Operation of the pCAVS was found to cause some additional outgassing, on the order of 10−8 Pa l/s, which can be mitigated in the future by better thermal management.
We describe the cold-atom vacuum standards (CAVS) under development at the National Institute of Standards and Technology (NIST). The CAVS measures pressure in the ultra-high and extreme-high vacuum regimes by measuring the loss rate of sub-millikelvin sensor atoms from a magnetic trap. Ab initio quantum scattering calculations of cross sections and rate coefficients relate the density of background gas molecules or atoms to the loss rate of ultra-cold sensor atoms. The resulting measurement of pressure through the ideal gas law is traceable to the second and the kelvin, making it a primary realization of the pascal. At NIST, two versions of the CAVS have been constructed: a laboratory standard used to achieve the lowest possible uncertainties and pressures, and a portable version that is a potential replacement for the Bayard-Alpert ionization gauge. Both types of CAVSs are connected to a combined extreme-high vacuum flowmeter and dynamic expansion system to enable sensing of a known pressure of gas. In the near future, we anticipate being able to compare the laboratory scale CAVS, the portable CAVS, and the flowmeter/dynamic expansion system to validate the operation of the CAVS as both a standard and vacuum gauge.
The lifetime of an atom trap is often limited by the presence of residual background gases in the vacuum chamber. This leads to the lifetime being inversely proportional to the pressure. Here, we use this dependence to estimate the pressure and to obtain pressure rate-of-rise curves, which are commonly used in vacuum science to evaluate the performance of a system. We observe different rates of pressure increase in response to different levels of outgassing in our system. Therefore, we suggest that this is a sensitive method which will find useful applications in cold atom systems, in particular, where the inclusion of a standard vacuum gauge is impractical.