Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Towards 0.5 THz Sideband Separation SIS Mixer for Radio Astronomy Receivers

Raquel Rodriguez Monje

Published Jan 1, 2005• 2 citations
OpenAlex

Related papers

Low Noise Single Sideband SIS Mixers for MM and Submillimeter Radio Astronomy [abstract]

Alexandre Karpov, J. Blondel, M. Voß +3 more

•Mar 1, 1998•0 citations

Low-noise THz-range Nb based SIS Receivers for Radio Astronomy

Kirill I. Rudakov, Andrey V. Khudchenko, Lyudmila V. Filippenko +4 more

This repost describes our results on development of low-noise heterodyne THz receivers for ground based and space radio astronomy. Superconductor-insulator-superconductor (SIS) mixers that employ high quality Nb-based tunnel junctions are the key element of the most sensitive heterodyne THz receivers. In particular we present here the SIS receivers for frequency range 211-275 GHz and 800-950 GHz with double sideband (DSB) noise temperature of about 25 K and 220 K, respectively. The latest results on development, fabrication techniques and experimental study of the SIS receivers will be discussed.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Nov 8, 2020•8 citations

Development of a submillimeter sideband-separating balanced SIS mixer

靖隆 芹澤

•Jan 1, 2010•2 citations

A 200-300 GHz single sideband SIS mixer for radio astronomy

Alexandre Karpov, J. Blondel, Dominique Billon-Pierron +1 more

We present an ultra broadband low noise single sideband (SSB) SIS mixer developed for 200-300 GHz radio astronomy receivers. The mixer uses two Nb/AlO/sub x//Nb junctions. Image band rejection by 20 dB is provided in the entire 200-300 GHz band using a mechanical tuning of the single noncontacting backshort in the mixer. The SIS receiver SSB noise temperature is close to 50 K in the main part of the band. A speed-up of the observations at radio telescopes by a factor 2-3 is expected with the new receiver.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•2 citations

Sideband-Separating SIS Mixer at 100GHz Band for Astronomical Observation

Shin’ichiro Asayama, Kimihiko Kimura, Hiroyuki Iwashita +6 more

Softwaretechnik-Trends•Jan 1, 2004•0 citations

Superconducting Sub-THz Receivers for Space and Ground-Based Radio Astronomy

V. P. Koshelets, Kirill I. Rudakov, Andrey V. Khudchenko +5 more

Abstract The developments in the field of low-noise receiving systems in the sub-THz range, performed at the Kotelnikov Institute of Radio Engineering of the Russian Academy of Sciences in recent years and aimed at the creation of receivers with quantum sensitivity for space and ground-based radio telescopes are presented. Superconductor–insulator–superconductor (SIS) mixers based on high-quality tunnel junctions are key elements of the most sensitive sub-THz heterodyne receivers. The article presents the results of the development of SIS receivers in the 211–275 GHz and 800–950 GHz ranges with a noise temperature in the double-sideband (DSB) mode of about 20 K and 220 K, respectively. These achievements will be used to develop receiving systems for APEX and LLMA ground-based telescopes, as well as for the Millimetron space mission.

Bulletin of the Lebedev Physics Institute•Sep 1, 2021•4 citations
This repost describes our results on development of low-noise heterodyne THz receivers for ground based and space radio astronomy. Superconductor-insulator-superconductor (SIS) mixers that employ high quality Nb-based tunnel junctions are the key element of the most sensitive heterodyne THz receivers. In particular we present here the SIS receivers for frequency range 211-275 GHz and 800-950 GHz with double sideband (DSB) noise temperature of about 25 K and 220 K, respectively. The latest results on development, fabrication techniques and experimental study of the SIS receivers will be discussed.
We present an ultra broadband low noise single sideband (SSB) SIS mixer developed for 200-300 GHz radio astronomy receivers. The mixer uses two Nb/AlO/sub x//Nb junctions. Image band rejection by 20 dB is provided in the entire 200-300 GHz band using a mechanical tuning of the single noncontacting backshort in the mixer. The SIS receiver SSB noise temperature is close to 50 K in the main part of the band. A speed-up of the observations at radio telescopes by a factor 2-3 is expected with the new receiver.
Abstract The developments in the field of low-noise receiving systems in the sub-THz range, performed at the Kotelnikov Institute of Radio Engineering of the Russian Academy of Sciences in recent years and aimed at the creation of receivers with quantum sensitivity for space and ground-based radio telescopes are presented. Superconductor–insulator–superconductor (SIS) mixers based on high-quality tunnel junctions are key elements of the most sensitive sub-THz heterodyne receivers. The article presents the results of the development of SIS receivers in the 211–275 GHz and 800–950 GHz ranges with a noise temperature in the double-sideband (DSB) mode of about 20 K and 220 K, respectively. These achievements will be used to develop receiving systems for APEX and LLMA ground-based telescopes, as well as for the Millimetron space mission.