Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Scientific Reports

Engineering preferentially-aligned nitrogen-vacancy centre ensembles in CVD grown diamond

Christian Osterkamp, Martin Mangold, Johannes Lang, Priyadharshini Balasubramanian, Tokuyuki Teraji, Boris Naydenov, Fedor Jelezko

Published Apr 8, 2019• 73 citations
Publisher

Abstract

C-enriched diamond aligned along the [111] crystal axis. The preferentially-aligned NV centres are fabricated by a Plasma Enhanced Chemical Vapour Deposition (PECVD) process and their concentration is quantitatively determined by analysing the confocal microscopy images. We further observe that annealing the samples at high temperature (1500 °C) in vacuum leads to a conversion of substitutional nitrogen into NV centres. This treatment also increases the coherence time of the NV centres electron spins up to 40 μs, which corresponds to enhancement of the sensitivity by a factor of three. However, this procedure also leads to a loss of the preferential alignment by 34%.

DOI
10.1038/s41598-019-42314-7

Related papers

Characterization and optimization of NV centers in CVD diamond for sensing applications

Tingpeng Luo, Lukas Lindner, Julia Langer +13 more

The negatively charged nitrogen-vacancy (NV-) center in diamond is a promising spin system for quantum sensing applications. NV-ensembles are favored for an improved signal-to-noise ratio and sensitivity. The optimization of diamond with NV-ensembles often requires a high NV concentration, a long spin coherence time T2 and a stable charge state. However, these key requirements are interdependent and can be difficult to optimize: nitrogen impurities as the main decoherence source of the NV spin limits the coherence time T2, and pursuing high NV concentration can deteriorate the NV-charge-state stability. Consequently, their best achievable combination becomes an essential question for the material characterization. In this work, we systematically investigate the NV center creation and properties in chemical vapor deposition (CVD) diamond. We have grown CVD diamond series with a varying nitrogen flow over four orders of magnitude, leading to a broad range of single substitutional nitrogen (P1 center) densities from 0.2 to 20 ppm. On these series, we study P1, NV creations and NV charge states after growth, as well as their transformation under subsequent electron beam irradiation. Furthermore, for a fixed nitrogen concentration, we optimize electron-irradiation fluences with two different accelerated electron energies. We discuss a general approach to determine the optimal irradiation conditions, for which an enhanced NV concentration and an optimum of NV charge states can both be satisfied. Moreover, through irradiation and annealing treatments, we monitor the change in T2 and aim to increase the NV density without compromising T2. We achieve NV concentrations from 1 to 168 ppb with T2 from 549 to 45.5 µs respectively. This study shows a pathway to engineer properties of NV-doped CVD diamonds for improved sensitivity.

•Jun 8, 2022•0 citations

Engineering colour centres in tailored diamond

Christian Osterkamp

When the word diamond comes up, the majority of people thinks about engagement rings or gemstones. In fact, it is additionally, one of the most promising host materials for the implementation of advanced technology, exploiting the nature of quantum physics. Such quantum technologies have disruptive potential, ones the quantum effects can be applied in macroscopic, commercial products. The nitrogen-vacancy (NV) centre in diamond is a promising candidate to perform such tasks in the fields of quantum computation, quantum cryptography or metrology. Especially in the field of quantum sensing, the NV sensor impresses with nano-scale spatial resolution paired with high sensitivity. The electronic spin of the atomic-sized point defect can be initialised, manipulated and read-out at ambient conditions and coherence lifetimes are comparably long. Diamond magnetometers based on negatively charged NV centres have shown to be very attractive, and the sensitivity goes down to the single-atom level. In order to exploit such a high sensitivity level for sensing prospects, in this thesis, the NV centres are fabricated well confined in a certain distance to the diamond surface, since the detectable field usually decays with the third power of the distance between sensor and target. The surface depicts a fracture of the spin wise protecting diamond lattice and charge fluctuations affect the stability of NV centres, which are overcome by diamond surface termination. In order to improve the sensitivity further, the sensor density, measurement contrast and interaction time are increased. The nitrogen doping technique, which is applied during a plasma-enhanced chemical vapour deposition (PECVD) diamond growth process is used to fabricate NV centre ensembles aligned along one diamond crystal axis, thereby improving the measurement contrast by a factor up to four. The interaction time limiting spin bath is analysed using the sensor capabilities of the NVs, which leads to enhanced growth strategies and the fabrication of sensitivity optimised NV centre ensembles for magnetometry applications.

•Jan 1, 2020•0 citations

Creation of NV-ensembles in CVD diamond for quantum sensing applications

T. Luo, Lukas Lindner, J. Langer +12 more

We systematically investigate the NV center creation and properties in bulk chemical vapor deposition (CVD) diamond, throughout growth, electron-beam irradiation, and annealing steps. We study diamond series grown with a varying nitrogen flow over 4 orders of magnitude, resulting in a broad range of single substitutional nitrogen (P1 center) densities from 0.2 to 20 ppm. We investigate in-situ P1 and NV creations, as well as NV charge states distributions. As the next step, we optimize electron-irradiation fluences for a fixed nitrogen concentration, with two different accelerated electron energies. We bring up a general approach to determine the optimal irradiation conditions, and discuss criteria for P1 to NV conversion ratios in the context of stable NV charge states. Through all these optimizations, we enhance the NV- concentration remarkably in our CVD diamond samples, without sacrificing their Hahn-echo coherence time T2. We achieve NV concentrations from 1 to 168 ppb with T2 from 549 to 45.5 µs respectively. This study shows a pathway to engineer targeted, optimized properties of NV-ensembles in bulk CVD diamonds for improved sensitivity.

•Sep 7, 2022•0 citations

Quantifying selective alignment of ensemble nitrogen-vacancy centers in (111) diamond

Kosuke Tahara, Hayato Ozawa, Takayuki Iwasaki +2 more

Selective alignment of nitrogen-vacancy (NV) centers in diamond is an important technique towards its applications. Quantification of the alignment ratio is necessary to design the optimized diamond samples. However, this is not a straightforward problem for dense ensemble of the NV centers. We estimate the alignment ratio of ensemble NV centers along the [111] direction in (111) diamond by optically detected magnetic resonance measurements. Diamond films deposited by N2 doped chemical vapor deposition have NV center densities over 1 × 1015 cm−3 and alignment ratios over 75%. Although spin coherence time (T2) is limited to a few μs by electron spins of nitrogen impurities, the combination of the selective alignment and the high density can be a possible way to optimize NV-containing diamond samples for the sensing applications.

Applied Physics Letters•Nov 9, 2015•38 citations

Creation of nitrogen-vacancy centers in chemical vapor deposition diamond for sensing applications

Tingpeng Luo, Lukas Lindner, J Langer +13 more

Abstract The nitrogen-vacancy (NV) center in diamond is a promising quantum system for magnetometry applications exhibiting optical readout of minute energy shifts in its spin sub-levels. Key material requirements for NV ensembles are a high NV − concentration, a long spin coherence time and a stable charge state. However, these are interdependent and can be difficult to optimize during diamond growth and subsequent NV creation. In this work, we systematically investigate the NV center formation and properties in bulk chemical vapor deposition (CVD) diamond. The nitrogen flow during growth is varied by over four orders of magnitude, resulting in a broad range of single substitutional nitrogen concentrations of 0.2–20 parts per million. For a fixed nitrogen concentration, we optimize electron-irradiation fluences with two different accelerated electron energies, and we study defect formation via optical characterizations. We discuss a general approach to determine the optimal irradiation conditions, for which an enhanced NV concentration and an optimum of NV charge states can both be satisfied. We achieve spin–spin coherence times T 2 ranging from 45.5 to 549 μ s for CVD diamonds containing 168 to 1 parts per billion NV − centers, respectively. This study shows a pathway to engineer properties of NV-doped CVD diamonds for improved sensitivity.

arXiv:2111.07981•New Journal of Physics•Feb 25, 2022•87 citations

Production of oriented nitrogen-vacancy color centers in synthetic diamond

Andrew Mark Edmonds, Ulrika F. S. D’Haenens-Johansson, Robin J. Cruddace +6 more

The negatively charged nitrogen-vacancy (${\mathrm{NV}}^{\ensuremath{-}}$) center in diamond is an attractive candidate for applications that range from magnetometry to quantum information processing. Here we show that only a fraction of the nitrogen (typically $<0.5$%) incorporated during homoepitaxial diamond growth by chemical vapor deposition (CVD) is in the form of undecorated ${\mathrm{NV}}^{\ensuremath{-}}$ centers. Furthermore, studies on CVD diamond grown on $(110)$-oriented substrates show a near 100% preferential orientation of NV centers along only the $[111]$ and $[\overline{1}\overline{1}1]$ directions, rather than the four possible orientations. The results indicate that NV centers grow in as units, as the diamond is deposited, rather than by migration and association of their components. The NV unit of the ${\mathrm{NVH}}^{\ensuremath{-}}$ is similarly preferentially oriented, but it is not possible to determine whether this defect was formed by H capture at a preferentially aligned NV center or as a complete unit. Reducing the number of NV orientations from four orientations to two orientations should lead to increased optically detected magnetic resonance contrast and thus improved magnetic sensitivity in ensemble-based magnetometry.

arXiv:1112.5757•Physical Review B•Jul 5, 2012•181 citations
C-enriched diamond aligned along the [111] crystal axis. The preferentially-aligned NV centres are fabricated by a Plasma Enhanced Chemical Vapour Deposition (PECVD) process and their concentration is quantitatively determined by analysing the confocal microscopy images. We further observe that annealing the samples at high temperature (1500 °C) in vacuum leads to a conversion of substitutional nitrogen into NV centres. This treatment also increases the coherence time of the NV centres electron spins up to 40 μs, which corresponds to enhancement of the sensitivity by a factor of three. However, this procedure also leads to a loss of the preferential alignment by 34%.
The negatively charged nitrogen-vacancy (NV-) center in diamond is a promising spin system for quantum sensing applications. NV-ensembles are favored for an improved signal-to-noise ratio and sensitivity. The optimization of diamond with NV-ensembles often requires a high NV concentration, a long spin coherence time T2 and a stable charge state. However, these key requirements are interdependent and can be difficult to optimize: nitrogen impurities as the main decoherence source of the NV spin limits the coherence time T2, and pursuing high NV concentration can deteriorate the NV-charge-state stability. Consequently, their best achievable combination becomes an essential question for the material characterization. In this work, we systematically investigate the NV center creation and properties in chemical vapor deposition (CVD) diamond. We have grown CVD diamond series with a varying nitrogen flow over four orders of magnitude, leading to a broad range of single substitutional nitrogen (P1 center) densities from 0.2 to 20 ppm. On these series, we study P1, NV creations and NV charge states after growth, as well as their transformation under subsequent electron beam irradiation. Furthermore, for a fixed nitrogen concentration, we optimize electron-irradiation fluences with two different accelerated electron energies. We discuss a general approach to determine the optimal irradiation conditions, for which an enhanced NV concentration and an optimum of NV charge states can both be satisfied. Moreover, through irradiation and annealing treatments, we monitor the change in T2 and aim to increase the NV density without compromising T2. We achieve NV concentrations from 1 to 168 ppb with T2 from 549 to 45.5 µs respectively. This study shows a pathway to engineer properties of NV-doped CVD diamonds for improved sensitivity.
When the word diamond comes up, the majority of people thinks about engagement rings or gemstones. In fact, it is additionally, one of the most promising host materials for the implementation of advanced technology, exploiting the nature of quantum physics. Such quantum technologies have disruptive potential, ones the quantum effects can be applied in macroscopic, commercial products. The nitrogen-vacancy (NV) centre in diamond is a promising candidate to perform such tasks in the fields of quantum computation, quantum cryptography or metrology. Especially in the field of quantum sensing, the NV sensor impresses with nano-scale spatial resolution paired with high sensitivity. The electronic spin of the atomic-sized point defect can be initialised, manipulated and read-out at ambient conditions and coherence lifetimes are comparably long. Diamond magnetometers based on negatively charged NV centres have shown to be very attractive, and the sensitivity goes down to the single-atom level. In order to exploit such a high sensitivity level for sensing prospects, in this thesis, the NV centres are fabricated well confined in a certain distance to the diamond surface, since the detectable field usually decays with the third power of the distance between sensor and target. The surface depicts a fracture of the spin wise protecting diamond lattice and charge fluctuations affect the stability of NV centres, which are overcome by diamond surface termination. In order to improve the sensitivity further, the sensor density, measurement contrast and interaction time are increased. The nitrogen doping technique, which is applied during a plasma-enhanced chemical vapour deposition (PECVD) diamond growth process is used to fabricate NV centre ensembles aligned along one diamond crystal axis, thereby improving the measurement contrast by a factor up to four. The interaction time limiting spin bath is analysed using the sensor capabilities of the NVs, which leads to enhanced growth strategies and the fabrication of sensitivity optimised NV centre ensembles for magnetometry applications.
We systematically investigate the NV center creation and properties in bulk chemical vapor deposition (CVD) diamond, throughout growth, electron-beam irradiation, and annealing steps. We study diamond series grown with a varying nitrogen flow over 4 orders of magnitude, resulting in a broad range of single substitutional nitrogen (P1 center) densities from 0.2 to 20 ppm. We investigate in-situ P1 and NV creations, as well as NV charge states distributions. As the next step, we optimize electron-irradiation fluences for a fixed nitrogen concentration, with two different accelerated electron energies. We bring up a general approach to determine the optimal irradiation conditions, and discuss criteria for P1 to NV conversion ratios in the context of stable NV charge states. Through all these optimizations, we enhance the NV- concentration remarkably in our CVD diamond samples, without sacrificing their Hahn-echo coherence time T2. We achieve NV concentrations from 1 to 168 ppb with T2 from 549 to 45.5 µs respectively. This study shows a pathway to engineer targeted, optimized properties of NV-ensembles in bulk CVD diamonds for improved sensitivity.
Selective alignment of nitrogen-vacancy (NV) centers in diamond is an important technique towards its applications. Quantification of the alignment ratio is necessary to design the optimized diamond samples. However, this is not a straightforward problem for dense ensemble of the NV centers. We estimate the alignment ratio of ensemble NV centers along the [111] direction in (111) diamond by optically detected magnetic resonance measurements. Diamond films deposited by N2 doped chemical vapor deposition have NV center densities over 1 × 1015 cm−3 and alignment ratios over 75%. Although spin coherence time (T2) is limited to a few μs by electron spins of nitrogen impurities, the combination of the selective alignment and the high density can be a possible way to optimize NV-containing diamond samples for the sensing applications.
Abstract The nitrogen-vacancy (NV) center in diamond is a promising quantum system for magnetometry applications exhibiting optical readout of minute energy shifts in its spin sub-levels. Key material requirements for NV ensembles are a high NV − concentration, a long spin coherence time and a stable charge state. However, these are interdependent and can be difficult to optimize during diamond growth and subsequent NV creation. In this work, we systematically investigate the NV center formation and properties in bulk chemical vapor deposition (CVD) diamond. The nitrogen flow during growth is varied by over four orders of magnitude, resulting in a broad range of single substitutional nitrogen concentrations of 0.2–20 parts per million. For a fixed nitrogen concentration, we optimize electron-irradiation fluences with two different accelerated electron energies, and we study defect formation via optical characterizations. We discuss a general approach to determine the optimal irradiation conditions, for which an enhanced NV concentration and an optimum of NV charge states can both be satisfied. We achieve spin–spin coherence times T 2 ranging from 45.5 to 549 μ s for CVD diamonds containing 168 to 1 parts per billion NV − centers, respectively. This study shows a pathway to engineer properties of NV-doped CVD diamonds for improved sensitivity.
The negatively charged nitrogen-vacancy (${\mathrm{NV}}^{\ensuremath{-}}$) center in diamond is an attractive candidate for applications that range from magnetometry to quantum information processing. Here we show that only a fraction of the nitrogen (typically <0.5<0.5<0.5%) incorporated during homoepitaxial diamond growth by chemical vapor deposition (CVD) is in the form of undecorated ${\mathrm{NV}}^{\ensuremath{-}}$ centers. Furthermore, studies on CVD diamond grown on (110)(110)(110)-oriented substrates show a near 100% preferential orientation of NV centers along only the [111][111][111] and [1‾1‾1][\overline{1}\overline{1}1][111] directions, rather than the four possible orientations. The results indicate that NV centers grow in as units, as the diamond is deposited, rather than by migration and association of their components. The NV unit of the ${\mathrm{NVH}}^{\ensuremath{-}}$ is similarly preferentially oriented, but it is not possible to determine whether this defect was formed by H capture at a preferentially aligned NV center or as a complete unit. Reducing the number of NV orientations from four orientations to two orientations should lead to increased optically detected magnetic resonance contrast and thus improved magnetic sensitivity in ensemble-based magnetometry.