Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)

Coincidence detection of spatially correlated photon pairs with a novel type of monolithic time-resolving detector array

Manuel Unternährer, Bänz Bessire, Leonardo Gasparini, David Stoppa, André Stefanov

Published Jun 1, 2017• 2 citations
Publisher

Abstract

Spatially entangled photon states are used in experiments addressing fundamental properties of quantum mechanics as well as practical applications [1]. Thereby, the use of these states demands for time-saving detection mechanisms, capable of measuring coincidences between spatially separated photons with high spatial and temporal resolution. In this work, we demonstrate coincidence detection of spatially correlated photon pairs by means of the SPADnet-I sensor [2], a fully digital 8×16 pixel single photon detector array in CMOS technology developed for medical applications. It enables per-pixel time stamping with 265 ps resolution combined with a high frame rate of 500 kfps [3]. Commonly used optically or electrically amplified CCD based systems exhibit magnitudes lower frame rates and temporal resolution.

DOI
10.1109/cleoe-eqec.2017.8086459

Related papers

Coincidence detection of spatially correlated photon pairs with a monolithic time-resolving detector array

Manuel Unternährer, Bänz Bessire, Leonardo Gasparini +2 more

We demonstrate coincidence measurements of spatially entangled photons by means of a multi-pixel based detection array. The sensor, originally developed for positron emission tomography applications, is a fully digital 8×16 silicon photomultiplier array allowing not only photon counting but also per-pixel time stamping of the arrived photons with an effective resolution of 265 ps. Together with a frame rate of 500 kfps, this property exceeds the capabilities of conventional charge-coupled device cameras which have become of growing interest for the detection of transversely correlated photon pairs. The sensor is used to measure a second-order correlation function for various non-collinear configurations of entangled photons generated by spontaneous parametric down-conversion. The experimental results are compared to theory.

arXiv:1609.03419•Optics Express•Dec 5, 2016•34 citations

Coincidence detection of spatially correlated photon pairs with a novel type of monolithic time-resolving detector array

Bänz Bessire, Manuel Unternährer, Leonardo Gasparini +2 more

We demonstrate a novel type of multi-pixel detector array which enables per-pixel time stamping with sub-nanosecond timing resolution and a high frame rate by measuring second-order correlation functions of transverse momentum entangled photons.

Quantum Information and Measurement (QIM)•Jan 1, 2017•2 citations

Characterization of space-momentum entangled photons with a time resolving CMOS SPAD array

Bruno Eckmann, Bänz Bessire, Manuel Unternährer +3 more

Single-photon avalanche diode arrays can provide both the spatial and temporal information of each detected photon. We present here the characterization of spatially entangled photons with a 32 × 32 pixel sensor, specifically designed for quantum imaging applications. The sensor is time-tagging each detection event at pixel level with sub-nanosecond accuracy within frames of 50 ns. The spatial correlations between any number of detections in a defined temporal window can thus be directly extracted from the data.The space-momentum entanglement of photon pairs is demonstrated by violating an EPR-type inequality directly from the measured near-field correlations and far-field anti-correlations.

arXiv:2006.10791•Optics Express•Sep 13, 2020•29 citations

Real-time entangled photon-pair imaging towards field deployment

Robin Camphausen, Álvaro Cuevas, Alexander Demuth +8 more

Quantum technology promises improvements in imaging, computing, and communication, for example using the resource of entanglement between photons with spatial correlations. Detecting spatial correlations, or coincidences, between entangled photons scalably, efficiently, and affordably is therefore an essential capability. However, this task is non-trivial for existing camera technologies, which require low illumination intensities or low detection duty cycles to count coincidences at high signal-to-noise ratios, resulting in long acquisition time, or use expensive custom electronic components. Here, we present an entanglement imaging system based around a novel Single-Photon Avalanche Diode (SPAD) array camera, optimized for sparse illumination with correlated photon pairs. The system is capable of maintaining a duty cycle close to 100%, while simultaneously detecting spatially resolved coincidences with high SNR, enabling the acquisition of real-time entanglement videos at a ~Hz frame rate. We use our system to demonstrate real-time monitoring of entanglement interference visibility, optical system point spread function, as well as real-time widefield entanglement-enhanced phase imaging. Our results show that SPAD array cameras represent a natural choice for scalable entanglement detection and imaging applications.

•Nov 30, 2023•1 citation

Quantum correlations measured with multi-pixel detectors

Frauke Izdebski

use of any of the information contained in it must acknowledge this thesis as the source of the quotation or information. This thesis investigates the measurement of spatial correlations of photon pairs gener-ated through spontaneous parametric down-conversion with single-photon sensitive multi-pixel detectors. A custom designed and fabricated 8×1 fibre array detector for time to position multi-plexing was characterised. This detector was then commissioned in an experiment measuring the spatial correlations of photon pairs in position, momentum and in-termediate bases. The fibre array measured eight positions simultaneously with one Single-Photon Avalanche Diode, which led to an eight-fold increase in the data ac-quisition rate compared to traditional experiments, where a single SPAD was scanned across the detection plane. To capture all of the emitted light, an electron-multiplying CCD (EMCCD) camera was used. The spatial correlations were measured for the first time in momentum and pos-

•Aug 1, 2013•0 citations

Analysis of a quantum imaging system based on SPAD detection

Fabio Severini, Francesca Madonini, Federica Villa

The ability to generate and handle quantum correlations in twin-beam states is the foundation to overcome the imaging limitations imposed by classical light [1], relying on efficient detectors able to select temporal correlations among photons with maximized signal-to-noise ratio. Indeed, quantum information is contained in the interaction with the sample of just two photons, thus losing even one of them or mixing them up with background can completely compromise the experiment. To this end, assessing and evaluating the expected probability of measurement errors is of utmost importance to optimize the detector design. A typical experimental setup of a quantum imaging system based on Spontaneous Parametric Down Conversion (SPDC), the most effective way of producing temporally and spatially correlated entangled photons [2], involves a pump laser hitting a non-linear birefringent crystal producing a down-converted signal, some passive optical components to generate polarization-entangled photons and a pixelated photon detector that eventually reveals the position of coincident entangled photons. The overall detection efficiency of the measurement setup (i.e. heralding efficiency ηH) gathers all its possible losses and non-idealities of the mentioned setup components, namely the crystal conversion efficiency, the optical losses, the detector Photon Detection Efficiency (PDE) and fill-factor. In this study, we consider a detection based on a Single Photon Avalanche Diode (SPAD) array, able to detect coincidences on-chip and with event-driven architecture, which provides fast readout, low power consumption and optimized data throughput. However, related to every on-chip coincidence detection and event-driven based architecture, some operations require a certain amount of time to be performed that, combined with the generation of undesired single photons (both due to limited heralding efficiency and SPAD Dark Count Rate, DCR), yield to three measurement errors, here described with their related probabilities. Firstly, due to the finite duration of the coincidence window ∆tCOINC, there exist a probability Pfalseof wrongly detecting as coincident photons two single photons, and can be expressed as:\begin{equation*}{P_{false}} = \frac{{\left[ {2{\mu _{SOURCE{\text{ }}}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\left( {1 - {e^{ - \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\Delta {t_{COINC}}}}} \right)}}{{{\mu _{SOURCE}}\eta _H^2 + \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + DCR} \right]\left( {1 - {e^{ - \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\Delta {t_{COINC}}}}} \right)}}\tag{1}\end{equation*}where µSOURCEis the number of photon pairs generated by an ideal non-linear crystal. Secondly, in the time needed for the array to "freeze" the pixels state after a coincidence event (∆tFREEZE) so that they can be readout, there is the probability Pspuriousof detecting a third spurious event after a coincidence has been detected, which is expressed as:\begin{equation*}{P_{spurious}} = 1 - {e^{ - \left[ {2{\mu _{SOURCE\eta }}_H\left( {1 - {\eta _H}} \right) + DCR} \right]\Delta {t_{FREEZE}}}}\tag{2}\end{equation*}

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 21, 2021•0 citations
Spatially entangled photon states are used in experiments addressing fundamental properties of quantum mechanics as well as practical applications [1]. Thereby, the use of these states demands for time-saving detection mechanisms, capable of measuring coincidences between spatially separated photons with high spatial and temporal resolution. In this work, we demonstrate coincidence detection of spatially correlated photon pairs by means of the SPADnet-I sensor [2], a fully digital 8×16 pixel single photon detector array in CMOS technology developed for medical applications. It enables per-pixel time stamping with 265 ps resolution combined with a high frame rate of 500 kfps [3]. Commonly used optically or electrically amplified CCD based systems exhibit magnitudes lower frame rates and temporal resolution.
We demonstrate coincidence measurements of spatially entangled photons by means of a multi-pixel based detection array. The sensor, originally developed for positron emission tomography applications, is a fully digital 8×16 silicon photomultiplier array allowing not only photon counting but also per-pixel time stamping of the arrived photons with an effective resolution of 265 ps. Together with a frame rate of 500 kfps, this property exceeds the capabilities of conventional charge-coupled device cameras which have become of growing interest for the detection of transversely correlated photon pairs. The sensor is used to measure a second-order correlation function for various non-collinear configurations of entangled photons generated by spontaneous parametric down-conversion. The experimental results are compared to theory.
Single-photon avalanche diode arrays can provide both the spatial and temporal information of each detected photon. We present here the characterization of spatially entangled photons with a 32 × 32 pixel sensor, specifically designed for quantum imaging applications. The sensor is time-tagging each detection event at pixel level with sub-nanosecond accuracy within frames of 50 ns. The spatial correlations between any number of detections in a defined temporal window can thus be directly extracted from the data.The space-momentum entanglement of photon pairs is demonstrated by violating an EPR-type inequality directly from the measured near-field correlations and far-field anti-correlations.
Quantum technology promises improvements in imaging, computing, and communication, for example using the resource of entanglement between photons with spatial correlations. Detecting spatial correlations, or coincidences, between entangled photons scalably, efficiently, and affordably is therefore an essential capability. However, this task is non-trivial for existing camera technologies, which require low illumination intensities or low detection duty cycles to count coincidences at high signal-to-noise ratios, resulting in long acquisition time, or use expensive custom electronic components. Here, we present an entanglement imaging system based around a novel Single-Photon Avalanche Diode (SPAD) array camera, optimized for sparse illumination with correlated photon pairs. The system is capable of maintaining a duty cycle close to 100%, while simultaneously detecting spatially resolved coincidences with high SNR, enabling the acquisition of real-time entanglement videos at a ~Hz frame rate. We use our system to demonstrate real-time monitoring of entanglement interference visibility, optical system point spread function, as well as real-time widefield entanglement-enhanced phase imaging. Our results show that SPAD array cameras represent a natural choice for scalable entanglement detection and imaging applications.
use of any of the information contained in it must acknowledge this thesis as the source of the quotation or information. This thesis investigates the measurement of spatial correlations of photon pairs gener-ated through spontaneous parametric down-conversion with single-photon sensitive multi-pixel detectors. A custom designed and fabricated 8×1 fibre array detector for time to position multi-plexing was characterised. This detector was then commissioned in an experiment measuring the spatial correlations of photon pairs in position, momentum and in-termediate bases. The fibre array measured eight positions simultaneously with one Single-Photon Avalanche Diode, which led to an eight-fold increase in the data ac-quisition rate compared to traditional experiments, where a single SPAD was scanned across the detection plane. To capture all of the emitted light, an electron-multiplying CCD (EMCCD) camera was used. The spatial correlations were measured for the first time in momentum and pos-
The ability to generate and handle quantum correlations in twin-beam states is the foundation to overcome the imaging limitations imposed by classical light [1], relying on efficient detectors able to select temporal correlations among photons with maximized signal-to-noise ratio. Indeed, quantum information is contained in the interaction with the sample of just two photons, thus losing even one of them or mixing them up with background can completely compromise the experiment. To this end, assessing and evaluating the expected probability of measurement errors is of utmost importance to optimize the detector design. A typical experimental setup of a quantum imaging system based on Spontaneous Parametric Down Conversion (SPDC), the most effective way of producing temporally and spatially correlated entangled photons [2], involves a pump laser hitting a non-linear birefringent crystal producing a down-converted signal, some passive optical components to generate polarization-entangled photons and a pixelated photon detector that eventually reveals the position of coincident entangled photons. The overall detection efficiency of the measurement setup (i.e. heralding efficiency ηH) gathers all its possible losses and non-idealities of the mentioned setup components, namely the crystal conversion efficiency, the optical losses, the detector Photon Detection Efficiency (PDE) and fill-factor. In this study, we consider a detection based on a Single Photon Avalanche Diode (SPAD) array, able to detect coincidences on-chip and with event-driven architecture, which provides fast readout, low power consumption and optimized data throughput. However, related to every on-chip coincidence detection and event-driven based architecture, some operations require a certain amount of time to be performed that, combined with the generation of undesired single photons (both due to limited heralding efficiency and SPAD Dark Count Rate, DCR), yield to three measurement errors, here described with their related probabilities. Firstly, due to the finite duration of the coincidence window ∆tCOINC, there exist a probability Pfalseof wrongly detecting as coincident photons two single photons, and can be expressed as:\begin{equation*}{P_{false}} = \frac{{\left[ {2{\mu _{SOURCE{\text{ }}}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\left( {1 - {e^{ - \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\Delta {t_{COINC}}}}} \right)}}{{{\mu _{SOURCE}}\eta _H^2 + \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + DCR} \right]\left( {1 - {e^{ - \left[ {2{\mu _{SOURCE}}{\eta _H}\left( {1 - {\eta _H}} \right) + {\text{DCR}}} \right]\Delta {t_{COINC}}}}} \right)}}\tag{1}\end{equation*}where µSOURCEis the number of photon pairs generated by an ideal non-linear crystal. Secondly, in the time needed for the array to "freeze" the pixels state after a coincidence event (∆tFREEZE) so that they can be readout, there is the probability Pspuriousof detecting a third spurious event after a coincidence has been detected, which is expressed as:\begin{equation*}{P_{spurious}} = 1 - {e^{ - \left[ {2{\mu _{SOURCE\eta }}_H\left( {1 - {\eta _H}} \right) + DCR} \right]\Delta {t_{FREEZE}}}}\tag{2}\end{equation*}