Optik

Coherent population trapping spectral line characteristics for high sensitivity magnetic field measurement

Xiao-nan Zhang, Jian-zhi Sang, Jie Li, Jun Kou, Zhang Ren

Published Dec 10, 2018• 1 citation
Publisher
DOI
10.1016/j.ijleo.2018.12.022

Related papers

Coherent population trapping to measure magnetic fields in hydrogen plasma

James M. Mitrani, D. R. Farley, S. Cohen

Bulletin of the American Physical Society•Nov 2, 2009•0 citations

High sensitively coherent population trapping magnetometer with optically pumped degenerate atoms

Ryo Maeda, Shigeyoshi Goka

A high sensitive coherent population trapping (CPT) magnetometer with optically pumped degenerate state atoms has been developed. The CPT magnetometer in degenerate state, which does not require large magnetic field, has high sensitivity as a CPT magnetometer while keeping simple configuration. Our measurement system achieved magnetic sensitivity of 1pT/√Hz using this technique.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•2 citations

Investigation of the nonlinear CPT spectrum of 87 Rb and its application for large dynamic magnetic measurement

Chi Xu, Shiguang Wang, Yong Hu +2 more

The coherent population trapping (CPT) phenomenon has found widespread application in quantum precision measurements. Various designs based on the narrow resonant spectrum corresponding to the linear Zeeman effect have been demonstrated to achieve high performance. In this article, the nonlinear Zeeman split of the CPT spectrum of 87 Rb in the lin ∥ lin setup is investigated. We observe re-split phenomenon for both magnetic sensitive and magnetic insensitive CPT resonant lines at a large magnetic field. The re-split in the magnetic sensitive lines raises a practical problem to magnetometers worked in the lin ∥ lin setup while the other one shows a good potential for applications in large magnetic field. We propose a design based on the nonlinear split of the magnetic insensitive lines and test its performance. It provides a much larger measurement range compared to the linear one, offering an option for atomic magnetometers where a large dynamic range is preferred.

Chinese Physics B•Jun 1, 2017•4 citations

The Measurement of Simulative Weak Magnetic Field with a Cesium Magnetometer Based on Coherent Population Trapping

温馨 Wen Xin, 刘智 Liu Zhi, 王杰英 WANG Jie-ying +3 more

Acta Sinica Quantum Optica•Jan 1, 2013•0 citations

Potential of the Single-Frequency CPT Resonances for Magnetic Field Measurement

Emilia A. Alipieva, S. Gateva, Elena T. Taskova

Coherent population trapping (CPT) resonances on degenerate two-level system of D/sub 1/ line of /sup 87/Rb were investigated with single-frequency laser excitation in Hanle configuration. Their sensitivity to stray magnetic fields was examined for linear, elliptical, and circular laser polarization. A methodology for magnetic field (MF) measurement using the CPT resonance is proposed. The sensitivity of the system to weak magnetic fields was evaluated and a magnetic field of 3 nT was unambiguously detected.

IEEE Transactions on Instrumentation and Measurement•Mar 21, 2005•16 citations

A coherent population trapping magnetometer using a phase-delayed differential detection method

Pengcheng Du, Jiahao Yuan, Feifan Yang +2 more

Optics & Laser Technology•Apr 30, 2024•6 citations
The coherent population trapping (CPT) phenomenon has found widespread application in quantum precision measurements. Various designs based on the narrow resonant spectrum corresponding to the linear Zeeman effect have been demonstrated to achieve high performance. In this article, the nonlinear Zeeman split of the CPT spectrum of 87 Rb in the lin ∥ lin setup is investigated. We observe re-split phenomenon for both magnetic sensitive and magnetic insensitive CPT resonant lines at a large magnetic field. The re-split in the magnetic sensitive lines raises a practical problem to magnetometers worked in the lin ∥ lin setup while the other one shows a good potential for applications in large magnetic field. We propose a design based on the nonlinear split of the magnetic insensitive lines and test its performance. It provides a much larger measurement range compared to the linear one, offering an option for atomic magnetometers where a large dynamic range is preferred.
Coherent population trapping (CPT) resonances on degenerate two-level system of D/sub 1/ line of /sup 87/Rb were investigated with single-frequency laser excitation in Hanle configuration. Their sensitivity to stray magnetic fields was examined for linear, elliptical, and circular laser polarization. A methodology for magnetic field (MF) measurement using the CPT resonance is proposed. The sensitivity of the system to weak magnetic fields was evaluated and a magnetic field of 3 nT was unambiguously detected.