Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Low Temperature Physics

Investigation of Single-Crystal Niobium for Microwave Kinetic Inductance Detectors

Agnès Dominjon, S. Shu, M. Kroug, Takashi Noguchi, Yutaro Sekímoto, Wenlei Shan, Shigeyuki Sekiguchi, Tom Nitta

Published Dec 5, 2018• 5 citations
Publisher
DOI
10.1007/s10909-018-2101-2

Related papers

Investigation of Optical Coupling in Microwave Kinetic Inductance Detectors Using Superconducting Reflective Plates

Paul Nicaise, Jie Hu, Jean-Marc Martin +6 more

arXiv:2207.02497•Journal of Low Temperature Physics•Jul 9, 2022•8 citations

Development of Microwave Kinetic Inductance Detectors for IR Single-Photon Counting

R. Mezzena, M. Faverzani, E. Ferri +5 more

Journal of Low Temperature Physics•Nov 10, 2019•12 citations

Antenna-coupled microwave kinetic inductance detectors

Peter K. Day, Henry George LeDuc, Alexey Goldin +5 more

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment•Jan 5, 2006•49 citations

Sensitivity of a Microwave Kinetic Inductance Detector (MKID)

Takashi Noguchi

The Japan Society of Applied Physics•Feb 13, 2013•0 citations

Characterization of two-level system noise for a microwave kinetic inductance detector comprising niobium film on a silicon substrate

Yoshinori Sueno, S. Honda, Hiroki Kutsuma +5 more

Abstract A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector. It comprises a resonator circuit constructed with a superconducting film on a dielectric substrate. To expand its field of application, it is important to establish a method to suppress the two-level system (TLS) noise that is caused by the electric fluctuations between the two energy states at the surface of the substrate. The electric field density can be decreased by expanding the strip width (S) and gap width from the ground plane (W) in the MKID circuit, allowing the suppression of TLS noise. However, this effect has not yet been confirmed for MKIDs made with niobium films on silicon substrates. In this study, we demonstrate its effectiveness for such MKIDs. We expanded the dimension of the circuit from (S, W) = (3.00 μm, 4.00 μm) to (S, W) = (5.00 μm, 23.7 μm), and achieved an increased suppression of 5.5 dB in TLS noise.

arXiv:2110.00127•Progress of Theoretical and Experimental Physics•Jan 31, 2022•8 citations

Design and Fabrication of Microwave Kinetic Inductance Detectors using NbN Symmetric Spiral Resonator Array

Kei Hayashi, Atsushi SAITO, Yasunobu Ogawa +9 more

We designed and fabricated a microwave kinetic inductance detector (MKID) using a niobium nitride (NbN) symmetric spiral resonator array. Previously we revealed that a rewound spiral structure works as not only a high-Q half-wavelength resonator but also as a broadband terahertz antenna. We conducted simulations for a 9 resonator array assuming NbN as the superconducting material and sapphire as the dielectric substrate, and obtained a maximum attenuation of over 30 dB and unloaded quality factors of over 2 × 10 5 for frequencies between 4.4 and 4.9 GHz. We fabricated the 9 resonator array MKID using NbN thin film deposited on an m-sapphire substrate by using dc magnetron sputtering. We observed half-wavelength resonances of around 4.5 GHz at 4 K. We measured the optical response of the MKID. The frequency shift was 0.5 MHz when illuminated with 650 nm photons.

Journal of Physics Conference Series•May 12, 2014•10 citations
Abstract A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector. It comprises a resonator circuit constructed with a superconducting film on a dielectric substrate. To expand its field of application, it is important to establish a method to suppress the two-level system (TLS) noise that is caused by the electric fluctuations between the two energy states at the surface of the substrate. The electric field density can be decreased by expanding the strip width (S) and gap width from the ground plane (W) in the MKID circuit, allowing the suppression of TLS noise. However, this effect has not yet been confirmed for MKIDs made with niobium films on silicon substrates. In this study, we demonstrate its effectiveness for such MKIDs. We expanded the dimension of the circuit from (S, W) = (3.00 μm, 4.00 μm) to (S, W) = (5.00 μm, 23.7 μm), and achieved an increased suppression of 5.5 dB in TLS noise.
We designed and fabricated a microwave kinetic inductance detector (MKID) using a niobium nitride (NbN) symmetric spiral resonator array. Previously we revealed that a rewound spiral structure works as not only a high-Q half-wavelength resonator but also as a broadband terahertz antenna. We conducted simulations for a 9 resonator array assuming NbN as the superconducting material and sapphire as the dielectric substrate, and obtained a maximum attenuation of over 30 dB and unloaded quality factors of over 2 × 10 5 for frequencies between 4.4 and 4.9 GHz. We fabricated the 9 resonator array MKID using NbN thin film deposited on an m-sapphire substrate by using dc magnetron sputtering. We observed half-wavelength resonances of around 4.5 GHz at 4 K. We measured the optical response of the MKID. The frequency shift was 0.5 MHz when illuminated with 650 nm photons.