Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)

Accurate Determination of the Landé g-Factors for 5s2 1S0 and 5s5p 3P0 States of the 87Sr Atom

Benquan Lu, Yebing Wang, Qinfang Xu, Mo-Juan Yin, Hong Chang

Published Jan 1, 2018• 0 citations
Publisher

Abstract

In the ultra-cold 87Sr atomic system, the Zeeman shift of the clock transition was measured with the σ±-polarized interrogation to accurately determine the g-factors of the 5s2 1S0 and 5s5p 3P0 states.
DOI
10.1364/cleopr.2018.tu3g.6

Related papers

Experimental Determination of the Landé g -Factors for 5 s 2 1 S and 5 s 5 p 3 P States of the 87 Sr Atom

Benquan Lu, Yebing Wang, Yang Guo +4 more

We present an experimental determination on the Landé g-factors for the 5s 2 1 S 0 and 5 s 5 p 3 P 0 states in ultra-cold atomic systems, which is important for evaluating the Zeeman shift of the clock transition in the 87 Sr optical lattice clock. The Zeeman shift of the 5s5p 3 P 0 –5s 2 1 S 0 forbidden transition is measured with the π-polarized and σ ± -polarized interrogations at different magnetic field strengths. Moreover, in the g-factor measurement with the σ ± -transition spectra, it is unnecessary to calibrate the external magnetic field. By this means, the ground state 5s 2 1 S 0 g-factor for the 87 Sr atom is −1.306(52)×10 −4 , which is the first experimental determination to the best of our knowledge, and the result matches very well with the theoretical estimation. The differential g-factor δg between the 5s5p 3 P 0 state and the 5s 2 1 S 0 state of the 87 Sr atoms is measured in the experiment as well, which are −7.67(36) × 10 −5 with π-transition spectra and −7.72(43) × 10 −5 with σ ± -transition spectra, in good agreement with the previous report [Phys. Rev. A 76 (2007) 022510]. This work can also be used for determining the differential g-factor of the clock states for the optical clocks based on other atoms .

Chinese Physics Letters•Apr 1, 2018•5 citations

Interrogation of spin polarized clock transition in strontium optical lattice clock

Yang Guo, Yin Mo-Juan, Qinfang Xu +5 more

We demonstrate a spin-polarized clock transition spectrum of the 87Sr optical lattice clock. The clock transition 5s2 1S05s5p 3P0 of isotope 87Sr has a hyperfine structure due to non-zero nuclear spin, inducing ten -polarized transitions from each individual mF state under the condition of a bias magnetic field along the probing polarization axis. In this experiment, atoms are driven to a certain mF state by a circular-polarization pump light to maximize the atomic population, which is beneficial to the stability and uncertainty evaluation of the optical lattice clock. After two stages cooling and trapping, about 3.5106 atoms are trapped in the red magneto-optical trap with a temperature of 3.9 K. A grating-feedback external cavity diode laser with a tapered amplifier is used to build the optical lattice with a magic-wavelength of 813.426 nm. Both waists of the counter-propagating lattice beam along the horizontal direction are overlapped to form a one-dimensional (1D) optical lattice. The lifetime of the atoms trapped in the 1D optical lattice is 1600 ms. The clock laser at 698 nm is a grating-feedback diode laser, which is locked to an ultra-low expansion cavity by the Pound-Drever-Hall technique to stabilize the frequency and phase. As a result, the linewidth of clock laser is narrowed to Hz level. By the normalized shelving method, we obtain a resolved sideband spectrum of 87Sr 5s2 1S05s5p 3P0 transition. According to the spectrum, the lattice temperature along the longitudinal direction is approximately 4.2 K. After that a linewidth of 6.7 Hz of the degenerate clock transition is obtained at a probing time of 150 ms by utilizing a three-dimensional (3D) bias magnetic field, which is used to eliminate the stray magnetic fields. Then a small bias magnetic field of 300 mGs is applied along the polarization axis of the lattice light to achieve the spectrum of Zeeman magnetic sublevels of the clock transition. Furthermore, the mF=+9/2 and mF=-9/2 magnetic sublevels are picked to be respectively pumped by the +-polarized and --polarized light at 689 nm, a variable liquid crystal wave plate is employed to switch on both polarizations. Finally, the spin polarized clock transition spectrum is obtained at the interrogating pulse of 150 ms, and the linewidths of the mF=+9/2, mF=-9/2 magnetic sublevel transitions are 6.8 Hz and 6.2 Hz respectively.

Acta Physica Sinica•Jan 1, 2018•2 citations

ISOTOPE SHIFT SPECTROSCOPY OF ULTRACOLD STRONTIUM

Neal C. Pisenti

We describe the design, construction, and performance of a laser system to probe the ultra-narrow (Γ/2π ≈ mHz) clock transition 1S0 → 3P0 in strontium. We present the first reported spectroscopy of this transition in two of the bosonic isotopes, 84Sr and 86Sr. Furthermore, we measure the complete set of isotope shifts between all four stable isotopes on the clock line and the narrow intercombination line 1S0 → 3P1, permitting a King plot analysis of the isotope shifts. Complications arising from the unambiguous determination of a line center in 87Sr 3P1 prevent us from making claims about the King linearity, but we provide a statistical boot- strap analysis of the isotope shifts 88−84Sr and 88−86Sr to compute a field shift ratio F698/F689 = 0.9979, with a 95% confidence interval [0.9952,1.0008]. The intercept term K698 − (F698/F689) K689 is similarly determined to be -2.0 GHz-amu, with a 95% confidence interval [−3.9, −0.3] GHz-amu. Finally, we describe the design of a next-generation apparatus that will enable improvements on the results described here, as well as other studies that involve coherent manipulation of strontium atoms on the clock line.

•Jan 1, 2019•1 citation

Ultrastable laser system for spectroscopy of the 1S0 – 3P0 clock transition in Sr atoms

O I Berdasov, A Yu Gribov, G S Belotelov +5 more

Ultrastable laser system for spectroscopy of the 1S0–3P0 clock transition in Sr atoms, Berdasov, O.I., Gribov, A.Yu., Belotelov, G.S., Pal’chikov, V.G., Strelkin, S.A., Khabarova, K.Yu., Kolachevsky, N.N., Slyusarev, S.N.

Quantum Electronics•May 9, 2017•9 citations

Observation of the hyperfine structure of the 2S1/2−2D5/2 transition in 87Sr+

G. P. Barwood, K. Gao, Patrick Robert Gill +2 more

The hyperfine structure of the ${}^{2}{S}_{1/2}{\ensuremath{-}}^{2}{D}_{5/2}$ quadrupole transition at 674 nm in ${}^{87}{\mathrm{Sr}}^{+}$ has been observed. The ion was confined in a Paul trap and cooled using laser radiation at 422 and 1092 nm. The quadrupole transition was observed by monitoring quantum jumps in the 422-nm fluorescence. The odd isotope of strontium has ``clock'' transitions independent of the first-order Zeeman shift and the ${}^{2}{D}_{5/2}$ state hyperfine structure constants have been determined as ${A}_{{D}_{5/2}}=2.1743(14)\mathrm{MHz}$ and ${B}_{{D}_{5/2}}=49.11(6)\mathrm{MHz}.$ Standard uncertainties have been added in parentheses. These values allow the second-order Zeeman shifts to be calculated. The ${}^{88}{\mathrm{Sr}}^{+}{\ensuremath{-}}^{87}{\mathrm{Sr}}^{+}$ isotope shift for the 674-nm quadrupole transition has been measured to be 247.99(4) MHz.

Physical Review A•Jan 8, 2003•44 citations

Recent Advances Concerning the 87Sr Optical Lattice Clock at the National Time Service Center

Yebing Wang, Xiaotong Lu, Benquan Lu +2 more

We review recent experimental progress concerning the 87Sr optical lattice clock at the National Time Service Center in China. Hertz-level spectroscopy of the 87Sr clock transition for the optical lattice clock was performed, and closed-loop operation of the optical lattice clock was realized. A fractional frequency instability of 2.8 × 10−17 was attained for an averaging time of 2000 s. The Allan deviation is found to be 1.6 × 10−15/τ1/2 and is limited mainly by white-frequency-noise. The Landé g-factors of the (5s2)1S0 and (5s5p)3P0 states in 87Sr were measured experimentally; they are important for evaluating the clock’s Zeeman shifts. We also present recent work on the miniaturization of the strontium optical lattice clock for space applications.

Applied Sciences•Nov 8, 2018•14 citations
We present an experimental determination on the Landé g-factors for the 5s 2 1 S 0 and 5 s 5 p 3 P 0 states in ultra-cold atomic systems, which is important for evaluating the Zeeman shift of the clock transition in the 87 Sr optical lattice clock. The Zeeman shift of the 5s5p 3 P 0 –5s 2 1 S 0 forbidden transition is measured with the π-polarized and σ ± -polarized interrogations at different magnetic field strengths. Moreover, in the g-factor measurement with the σ ± -transition spectra, it is unnecessary to calibrate the external magnetic field. By this means, the ground state 5s 2 1 S 0 g-factor for the 87 Sr atom is −1.306(52)×10 −4 , which is the first experimental determination to the best of our knowledge, and the result matches very well with the theoretical estimation. The differential g-factor δg between the 5s5p 3 P 0 state and the 5s 2 1 S 0 state of the 87 Sr atoms is measured in the experiment as well, which are −7.67(36) × 10 −5 with π-transition spectra and −7.72(43) × 10 −5 with σ ± -transition spectra, in good agreement with the previous report [Phys. Rev. A 76 (2007) 022510]. This work can also be used for determining the differential g-factor of the clock states for the optical clocks based on other atoms .
We demonstrate a spin-polarized clock transition spectrum of the 87Sr optical lattice clock. The clock transition 5s2 1S05s5p 3P0 of isotope 87Sr has a hyperfine structure due to non-zero nuclear spin, inducing ten -polarized transitions from each individual mF state under the condition of a bias magnetic field along the probing polarization axis. In this experiment, atoms are driven to a certain mF state by a circular-polarization pump light to maximize the atomic population, which is beneficial to the stability and uncertainty evaluation of the optical lattice clock. After two stages cooling and trapping, about 3.5106 atoms are trapped in the red magneto-optical trap with a temperature of 3.9 K. A grating-feedback external cavity diode laser with a tapered amplifier is used to build the optical lattice with a magic-wavelength of 813.426 nm. Both waists of the counter-propagating lattice beam along the horizontal direction are overlapped to form a one-dimensional (1D) optical lattice. The lifetime of the atoms trapped in the 1D optical lattice is 1600 ms. The clock laser at 698 nm is a grating-feedback diode laser, which is locked to an ultra-low expansion cavity by the Pound-Drever-Hall technique to stabilize the frequency and phase. As a result, the linewidth of clock laser is narrowed to Hz level. By the normalized shelving method, we obtain a resolved sideband spectrum of 87Sr 5s2 1S05s5p 3P0 transition. According to the spectrum, the lattice temperature along the longitudinal direction is approximately 4.2 K. After that a linewidth of 6.7 Hz of the degenerate clock transition is obtained at a probing time of 150 ms by utilizing a three-dimensional (3D) bias magnetic field, which is used to eliminate the stray magnetic fields. Then a small bias magnetic field of 300 mGs is applied along the polarization axis of the lattice light to achieve the spectrum of Zeeman magnetic sublevels of the clock transition. Furthermore, the mF=+9/2 and mF=-9/2 magnetic sublevels are picked to be respectively pumped by the +-polarized and --polarized light at 689 nm, a variable liquid crystal wave plate is employed to switch on both polarizations. Finally, the spin polarized clock transition spectrum is obtained at the interrogating pulse of 150 ms, and the linewidths of the mF=+9/2, mF=-9/2 magnetic sublevel transitions are 6.8 Hz and 6.2 Hz respectively.
We describe the design, construction, and performance of a laser system to probe the ultra-narrow (Γ/2π ≈ mHz) clock transition 1S0 → 3P0 in strontium. We present the first reported spectroscopy of this transition in two of the bosonic isotopes, 84Sr and 86Sr. Furthermore, we measure the complete set of isotope shifts between all four stable isotopes on the clock line and the narrow intercombination line 1S0 → 3P1, permitting a King plot analysis of the isotope shifts. Complications arising from the unambiguous determination of a line center in 87Sr 3P1 prevent us from making claims about the King linearity, but we provide a statistical boot- strap analysis of the isotope shifts 88−84Sr and 88−86Sr to compute a field shift ratio F698/F689 = 0.9979, with a 95% confidence interval [0.9952,1.0008]. The intercept term K698 − (F698/F689) K689 is similarly determined to be -2.0 GHz-amu, with a 95% confidence interval [−3.9, −0.3] GHz-amu. Finally, we describe the design of a next-generation apparatus that will enable improvements on the results described here, as well as other studies that involve coherent manipulation of strontium atoms on the clock line.
The hyperfine structure of the ${}^{2}{S}_{1/2}{\ensuremath{-}}^{2}{D}_{5/2}$ quadrupole transition at 674 nm in 87Sr+{}^{87}{\mathrm{Sr}}^{+}87Sr+ has been observed. The ion was confined in a Paul trap and cooled using laser radiation at 422 and 1092 nm. The quadrupole transition was observed by monitoring quantum jumps in the 422-nm fluorescence. The odd isotope of strontium has ``clock'' transitions independent of the first-order Zeeman shift and the 2D5/2{}^{2}{D}_{5/2}2D5/2​ state hyperfine structure constants have been determined as AD5/2=2.1743(14)MHz{A}_{{D}_{5/2}}=2.1743(14)\mathrm{MHz}AD5/2​​=2.1743(14)MHz and BD5/2=49.11(6)MHz.{B}_{{D}_{5/2}}=49.11(6)\mathrm{MHz}.BD5/2​​=49.11(6)MHz. Standard uncertainties have been added in parentheses. These values allow the second-order Zeeman shifts to be calculated. The ${}^{88}{\mathrm{Sr}}^{+}{\ensuremath{-}}^{87}{\mathrm{Sr}}^{+}$ isotope shift for the 674-nm quadrupole transition has been measured to be 247.99(4) MHz.
We review recent experimental progress concerning the 87Sr optical lattice clock at the National Time Service Center in China. Hertz-level spectroscopy of the 87Sr clock transition for the optical lattice clock was performed, and closed-loop operation of the optical lattice clock was realized. A fractional frequency instability of 2.8 × 10−17 was attained for an averaging time of 2000 s. The Allan deviation is found to be 1.6 × 10−15/τ1/2 and is limited mainly by white-frequency-noise. The Landé g-factors of the (5s2)1S0 and (5s5p)3P0 states in 87Sr were measured experimentally; they are important for evaluating the clock’s Zeeman shifts. We also present recent work on the miniaturization of the strontium optical lattice clock for space applications.