Conference on Precision Electromagnetic Measurements

High-Precision Magnetic Field Vector Measurement Based on the Quantum Coherent Superposition States

Yufeng Shi, Xiaoli Zhao, Shuang Gao, Wenguan Ren, Sipei Shao, Guoqing Yang

Published Jul 1, 2018• 1 citation
Publisher

Abstract

The high precision measurement of magnetic field vector based on quantum coherent superposition states due to the interaction of the atomic system with linearly polarized light and magnetic field is described. The coordinate systems are physically orthogonal, which defined by the directions of light polarization and propagation. Because the quantum beat signals resulted by the coherent superposition states are no longer affected by nonlinear Zeeman shift, the measurement has smaller systematic error. The method is suitable for the measurements of vector fields such as the Earth's magnetic field.

DOI
10.1109/cpem.2018.8501244

Related papers

In situ calibrated angle between the quantization axis and the propagating direction of the light field for trapping neutral atoms

Rui-Jun 瑞军 Guo 郭, Xiao-Dong 晓东 He 何, Cheng 诚 Sheng 盛 +7 more

The recently developed magic-intensity trapping technique of neutral atoms efficiently mitigates the detrimental effect of light shifts on atomic qubits and substantially enhances the coherence time. This technique relies on applying a bias magnetic field precisely parallel to the wave vector of a circularly polarized trapping laser field. However, due to the presence of the vector light shift experienced by the trapped atoms, it is challenging to precisely define a parallel magnetic field, especially at a low bias magnetic field strength, for the magic-intensity trapping of 85Rb qubits. In this work, we present a method to calibrate the angle between the bias magnetic field and the trapping laser field with the compensating magnetic fields in the other two directions orthogonal to the bias magnetic field direction. Experimentally, with a constant-depth trap and a fixed bias magnetic field, we measure the respective resonant frequencies of the atomic qubits in a linearly polarized trap and a circularly polarized one via the conventional microwave Rabi spectra with different compensating magnetic fields and obtain the corresponding total magnetic fields via the respective resonant frequencies using the Breit–Rabi formula. With known total magnetic fields, the angle is a function of the other two compensating magnetic fields. Finally, the projection value of the angle on either of the directions orthogonal to the bias magnetic field direction can be reduced to 0(4)° by applying specific compensating magnetic fields. The measurement error is mainly attributed to the fluctuation of atomic temperature. Moreover, it also demonstrates that, even for a small angle, the effect is strong enough to cause large decoherence of Rabi oscillation in a magic-intensity trap. Although the compensation method demonstrated here is explored for the magic-intensity trapping technique, it can be applied to a variety of similar precision measurements with trapped neutral atoms.

Chinese Physics B•Aug 17, 2023•1 citation

Magnetic-field measurements based on quantum superpositions

Szymon Pustelny, Maria Koczwara, Przemyslaw Wlodarczyk +1 more

The authors report on their investigations on nonlinear Faraday effect (NFE), i.e. light-intensity dependent rotation of the polarization plane of linearly polarized light upon its propagation through a medium placed in a magnetic field. The phenomenon is associated with quantum superpositions of atomic or molecular levels of particles constituting the medium. In this context it is based on the same grounds as electromagnetically induced transparency, coherent population trapping, storage and retrieval of light pulse from a medium. The paper also discusses the mechanisms of generation and detection of the superpositions with light and means of controllable tailoring of a quantum state in long-living (lifetimes >10 ms) atomic state.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2009•0 citations

Vector magnetic Field Measurement using Synchronous Coherent Population Trapping

G. S. Pati, Renu Tripathi, Mauricio Pulido +1 more

We are investigating magnetic resonance signals produced by SCPT to determine the direction of magnetic field. The essence of vector magnetic field measurement lies in studying the dependence of light transmission associated with SCPT resonances by rotating the linear polarization state of the light field. We are studying this effect by doing a proof-of-principle experiment in a rubidium vapor cell and also, using a theoretical model.

Frontiers in Optics•Jan 1, 2022•1 citation

Polarization rotation under two-photon Raman resonance for magnetometry

Swarupananda Pradhan, Rita Behera, A. K. Das

The polarization rotation and coherent population trapping signal arising due to two photon process using linearly polarized light are found to be significantly enhanced for a Zeeman degenerate system. The zero crossing of the dispersive profile is found to be shifting proportional to the applied magnetic field, albeit the absorptive profile position remains invariant for a slightly imbalanced orthogonal circular polarization component. It provides an alternative method for precise measurement of vector magnetic field without requirement of a bias field. The use of polarization rotation signal for magnetic field measurement offers added advantage due to improved signal to noise ratio.

Applied Physics Letters•Apr 23, 2012•17 citations

All-optical vector atomic magnetometer

E. Zhivun, Brian Patton, Chris Hovde +1 more

We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in a cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the AC Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of 50 fT/ √ Hz in measurement of the field magnitude and 0.5 mrad/ √ Hz in the field direction; elimination of technical noise would improve these sensitivities to 12 fT/ √ Hz and 5 μrad/ √ Hz, respectively. Applications for a precise all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.

Bulletin of the American Physical Society•Jun 5, 2014•24 citations

Accurate vector magnetometer via Zeeman Rabi oscillations

Thanmay S. Menon, D. P. Hewatt, Christopher Kiehl +3 more

Accurate magnetic field direction sensing in compact platforms is critical in applications spanning magnetic navigation, space science, and biomedical imaging. We demonstrate a single-optical-axis vector optically pumped magnetometer based on Rabi oscillations between Zeeman sublevels driven by a series of resonant radiofrequency (RF) polarization ellipses (PEs). A calibration protocol based on controlled rotations of the DC magnetic field determines the spatial orientation of each PE. We develop a detailed theoretical model describing the angular dependence of the Rabi frequencies, incorporating key systematics including RF Stark shifts and Bloch-Siegert shifts. We also account for an RF-based heading-error systematic affecting Rabi-frequency measurements arising from the nonlinear Zeeman effect. Simultaneous Larmor measurements yield the magnitude of the magnetic field, enabling integrated vector-scalar measurements. The magnetometer achieves deadzone-free vector operation with 80 $μ$rad mean angular accuracy and angular noise densities as low as 8 $μ$rad$/\sqrt{\mathrm{Hz}}$, offering a pathway towards miniaturized sensors without requiring 3D optical access or sensor rotations.

arXiv:2603.08594•Physical Review Applied•Oct 1, 2026•0 citations
The high precision measurement of magnetic field vector based on quantum coherent superposition states due to the interaction of the atomic system with linearly polarized light and magnetic field is described. The coordinate systems are physically orthogonal, which defined by the directions of light polarization and propagation. Because the quantum beat signals resulted by the coherent superposition states are no longer affected by nonlinear Zeeman shift, the measurement has smaller systematic error. The method is suitable for the measurements of vector fields such as the Earth's magnetic field.
The recently developed magic-intensity trapping technique of neutral atoms efficiently mitigates the detrimental effect of light shifts on atomic qubits and substantially enhances the coherence time. This technique relies on applying a bias magnetic field precisely parallel to the wave vector of a circularly polarized trapping laser field. However, due to the presence of the vector light shift experienced by the trapped atoms, it is challenging to precisely define a parallel magnetic field, especially at a low bias magnetic field strength, for the magic-intensity trapping of 85Rb qubits. In this work, we present a method to calibrate the angle between the bias magnetic field and the trapping laser field with the compensating magnetic fields in the other two directions orthogonal to the bias magnetic field direction. Experimentally, with a constant-depth trap and a fixed bias magnetic field, we measure the respective resonant frequencies of the atomic qubits in a linearly polarized trap and a circularly polarized one via the conventional microwave Rabi spectra with different compensating magnetic fields and obtain the corresponding total magnetic fields via the respective resonant frequencies using the Breit–Rabi formula. With known total magnetic fields, the angle is a function of the other two compensating magnetic fields. Finally, the projection value of the angle on either of the directions orthogonal to the bias magnetic field direction can be reduced to 0(4)° by applying specific compensating magnetic fields. The measurement error is mainly attributed to the fluctuation of atomic temperature. Moreover, it also demonstrates that, even for a small angle, the effect is strong enough to cause large decoherence of Rabi oscillation in a magic-intensity trap. Although the compensation method demonstrated here is explored for the magic-intensity trapping technique, it can be applied to a variety of similar precision measurements with trapped neutral atoms.
The authors report on their investigations on nonlinear Faraday effect (NFE), i.e. light-intensity dependent rotation of the polarization plane of linearly polarized light upon its propagation through a medium placed in a magnetic field. The phenomenon is associated with quantum superpositions of atomic or molecular levels of particles constituting the medium. In this context it is based on the same grounds as electromagnetically induced transparency, coherent population trapping, storage and retrieval of light pulse from a medium. The paper also discusses the mechanisms of generation and detection of the superpositions with light and means of controllable tailoring of a quantum state in long-living (lifetimes >10 ms) atomic state.
The polarization rotation and coherent population trapping signal arising due to two photon process using linearly polarized light are found to be significantly enhanced for a Zeeman degenerate system. The zero crossing of the dispersive profile is found to be shifting proportional to the applied magnetic field, albeit the absorptive profile position remains invariant for a slightly imbalanced orthogonal circular polarization component. It provides an alternative method for precise measurement of vector magnetic field without requirement of a bias field. The use of polarization rotation signal for magnetic field measurement offers added advantage due to improved signal to noise ratio.
We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in a cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the AC Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of 50 fT/ √ Hz in measurement of the field magnitude and 0.5 mrad/ √ Hz in the field direction; elimination of technical noise would improve these sensitivities to 12 fT/ √ Hz and 5 μrad/ √ Hz, respectively. Applications for a precise all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.
Accurate magnetic field direction sensing in compact platforms is critical in applications spanning magnetic navigation, space science, and biomedical imaging. We demonstrate a single-optical-axis vector optically pumped magnetometer based on Rabi oscillations between Zeeman sublevels driven by a series of resonant radiofrequency (RF) polarization ellipses (PEs). A calibration protocol based on controlled rotations of the DC magnetic field determines the spatial orientation of each PE. We develop a detailed theoretical model describing the angular dependence of the Rabi frequencies, incorporating key systematics including RF Stark shifts and Bloch-Siegert shifts. We also account for an RF-based heading-error systematic affecting Rabi-frequency measurements arising from the nonlinear Zeeman effect. Simultaneous Larmor measurements yield the magnitude of the magnetic field, enabling integrated vector-scalar measurements. The magnetometer achieves deadzone-free vector operation with 80 μμμrad mean angular accuracy and angular noise densities as low as 8 μμμrad/Hz/\sqrt{\mathrm{Hz}}/Hz​, offering a pathway towards miniaturized sensors without requiring 3D optical access or sensor rotations.