Conference on Precision Electromagnetic Measurements

Towards an Improved Programmable Quantum Current Generator

J. Azib, J. Brun-Picard, F. Schopfer, W. Poirier, Sophie Djordjevic

Published Jul 1, 2018• 3 citations
Publisher

Abstract

We report on a noise characterization and some on-going improvements of a programmable quantum current generator (PQCG) based on the extension of Ohm's law to quantum standards.
DOI
10.1109/cpem.2018.8501115

Related papers

Next generation Programmable Quantum Current Generator

Sophie Djordjevic, Ralf Behr, W. Poirier

This paper describes the latest improvements of the programmable quantum current generator (PQCG), which allow to get rid of the former 10−7relative corrections due to the resistance of the cable and extend the realization of the ampere over a wider current range, down to the µA range. Here we report on the first results of accuracy tests at 46 µA with a measurement uncertainty of one part in 108.

Conference on Precision Electromagnetic Measurements•Jul 8, 2024•0 citations

A7.3 - New developments for the programmable quantum current generator

Nils Huntemann, S. S. Djordjevic, W. Poirier

Lectures•Jan 1, 2023•0 citations

Downscaling currents with the programmable quantum current generator

Sophie Djordjevic, Kamel Dougdag, Ralf Behr +1 more

There is a challenge in downscaling quantized currents generated by the programmable quantum current generator (PQCG) to bridge the gap with other quantum sources and enable comparison of standards. Achieving this objective requires both simplifying and optimizing the settings of the full experiment, which involves two programmable Josepshon voltage standards (PJVS), two quantum Hall resistance standards and one cryogenic current comparator. Here, we describe an upgraded experiment involving a new cryogenic setup based on a pulse-tube refrigerator used to cool down the two PJVS. We demonstrate generation of quantized currents in the range from 4307 nA down to 359 nA with relative uncertainties ranging from 1 part to 9 parts in 108, respectively. The calibration of the ultra low current source from Magnicon using the PQCG is then demonstrated in same current ranges.

Conference on Precision Electromagnetic Measurements•Sep 1, 2026•0 citations

Towards a programmable quantum current generator

J. Brun-Picard, D. Leprat, F. Schopfer +2 more

We report on the development of a programmable quantum current generator (PQCG) based on quantum voltage and resistance standards. First measurements with a digital amperemeter in the 100 μA range demonstrate the linearity of the generated current as a function of the theoretical current, linked to the electron charge, with a relative uncertainty of 2.7 × 10-7(k = 1). To overcome the detector limits and validate the PQCG as a practical realization of the ampere in the new SI, accurate quantization measurements with a target combined uncertainty of a few parts in 108are in progress.

Conference on Precision Electromagnetic Measurements•Jul 1, 2016•0 citations

Precise Quantum Angle Generator Designed for Noisy Quantum Devices

Schnake, Simon Patrik, Rehm, Florian, Krücker, Dirk +4 more

Pos proceedings of science•Jan 1, 2024•0 citations

Establishing Programmable Josephson Voltage Standard and Maintaining Its Quantum Accuracy

TÜBİTAK Ulusal Metroloji Enstitüsü, P.K. 54, 41470, Gebze-Kocaeli, Turkey, Tezgül Coşkun Öztürk, Sarp Ertürk +4 more

International Journal of Electrical and Electronic Engineering & Telecommunications•Jan 1, 2019•6 citations
There is a challenge in downscaling quantized currents generated by the programmable quantum current generator (PQCG) to bridge the gap with other quantum sources and enable comparison of standards. Achieving this objective requires both simplifying and optimizing the settings of the full experiment, which involves two programmable Josepshon voltage standards (PJVS), two quantum Hall resistance standards and one cryogenic current comparator. Here, we describe an upgraded experiment involving a new cryogenic setup based on a pulse-tube refrigerator used to cool down the two PJVS. We demonstrate generation of quantized currents in the range from 4307 nA down to 359 nA with relative uncertainties ranging from 1 part to 9 parts in 108, respectively. The calibration of the ultra low current source from Magnicon using the PQCG is then demonstrated in same current ranges.
We report on the development of a programmable quantum current generator (PQCG) based on quantum voltage and resistance standards. First measurements with a digital amperemeter in the 100 μA range demonstrate the linearity of the generated current as a function of the theoretical current, linked to the electron charge, with a relative uncertainty of 2.7 × 10-7(k = 1). To overcome the detector limits and validate the PQCG as a practical realization of the ampere in the new SI, accurate quantization measurements with a target combined uncertainty of a few parts in 108are in progress.