M. Dovale Álvarez, Daniel Brown, A. W. Jones, Conor M Mow-Lowry, Haixing Miao, A. Freise

Published Aug 23, 2018• 0 citations
Publisher

Abstract

Atom interferometers employing optical cavities to enhance the beam splitter pulses promise significant advances in science and technology, notably for future gravitational wave detectors. Long cavities, on the scale of hundreds of meters, have been proposed in experiments aiming to become demonstrators for gravitational wave detection at frequencies below 1 Hz, where laser interferometers, such as LIGO, have poor sensitivity. Our group at the Birmingham Institute of Gravitational Wave Astronomy has explored the fundamental limitations of two-mirror cavities for atomic beam splitting, and established upper bounds on the temperature of the atomic ensemble as a function of cavity length and three design parameters: the cavity $g$-factor, the bandwidth, and the optical suppression factor of the first and second order spatial modes. A lower bound to the cavity bandwidth which avoids elongation of the interaction time and maximizes power enhancement was found. An upper limit to cavity length is also found for symmetric two-mirror cavities. These key limitations impact the feasibility of long-baseline detectors, which suffer from a naturally larger bandwidth and worse optical suppression of higher order optical modes. Our findings will aid the design of current and future experiments using this technology, such as the MIGA experiment in Bordeaux. In the future we aim to fully model the effect that the imperfect optical wavefronts have on the atomic transitions.

DOI
10.22323/1.325.0016

Related papers

Fundamental limitations of cavity-assisted atom interferometry

M. Dovale Álvarez, Daniel Brown, A. W. Jones +3 more

Atom interferometers employing optical cavities to enhance the beam splitter pulses promise significant advances in science and technology, notably for future gravitational wave detectors. Long cavities, on the scale of hundreds of meters, have been proposed in experiments aiming to observe gravitational waves with frequencies below 1 Hz, where laser interferometers, such as LIGO, have poor sensitivity. Alternatively, short cavities have also been proposed for enhancing the sensitivity of more portable atom interferometers. We explore the fundamental limitations of two-mirror cavities for atomic beam splitting, and establish upper bounds on the temperature of the atomic ensemble as a function of cavity length and three design parameters: the cavity $g$ factor, the bandwidth, and the optical suppression factor of the first and second order spatial modes. A lower bound to the cavity bandwidth is found which avoids elongation of the interaction time and maximizes power enhancement. An upper limit to cavity length is found for symmetric two-mirror cavities, restricting the practicality of long baseline detectors. For shorter cavities, an upper limit on the beam size was derived from the geometrical stability of the cavity. These findings aim to aid the design of current and future cavity-assisted atom interferometers.

arXiv:1710.02448•Physical Review A•Nov 8, 2017•24 citations

Fundamental Limitations Of Cavity-Assisted Atom Interferometry

D. D. Brown M. Dovale-Álvarez

Atom interferometers employing optical cavities to enhance the beam splitter pulses promise significant advances in science and technology, notably for future gravitational wave detectors. Long cavities, on the scale of hundreds of meters, have been proposed in experiments aiming to observe gravitational waves with frequencies below 1 Hz, where laser interferometers, such as LIGO, have poor sensitivity. Alternatively, short cavities have also been proposed for enhancing the sensitivity of more portable atom interferometers.We explore the fundamental limitations of two-mirror cavities for atomic beam splitting, and establish upper bounds on the temperature of the atomic ensemble as a function of cavity length and three design parameters: the cavity g factor, the bandwidth, and the optical suppression factor of the first and second order spatial modes. A lower bound to the cavity bandwidth is found which avoids elongation of the interaction time and maximizes power enhancement. An upper limit to cavity length is found for symmetric two-mirror cavities, restricting the practicality of long baseline detectors. For shorter cavities, an upper limit on the beam size was derived from the geometrical stability of the cavity. These findings aim to aid the design of current and future cavity-assisted atom interferometers.

•Nov 8, 2017•0 citations

Circulating pulse cavity enhancement as a method for extreme momentum transfer atom interferometry

Rustin Nourshargh, Samuel Lellouch, Sam Hedges +3 more

Abstract Large-scale atom interferometers promise unrivaled strain sensitivity to mid-band gravitational waves, and will probe a new parameter space in the search for ultra-light scalar dark matter. These proposals require gradiometry with kilometer-scale baselines, a momentum separation above 104ℏk between interferometer arms, and optical transitions to long-lived clock states to reach the target sensitivities. Prohibitively high optical power and wavefront flatness requirements have thus far limited the maximum achievable momentum splitting. Here we propose a scheme for optical cavity enhanced atom interferometry, using circulating, spatially resolved pulses, and intracavity frequency modulation to meet these requirements. We present parameters for the realization of 20 kW circulating pulses in a 1 km interferometer enabling 104ℏk splitting on the 698 nm clock transition in 87Sr. This scheme addresses the presently insurmountable laser power requirements and is feasible in the context of a kilometer-scale atom interferometer facility.

arXiv:2012.06426•Communications Physics•Dec 2, 2021•21 citations

Spatial and pulse efficiency constraints in atom interferometric gravitational wave detectors

Patrik Schach, Enno Giese

Abstract Currently planned and constructed terrestrial detectors for gravitational waves and dark matter based on differential light-pulse atom interferometry are designed around three primary strategies to enhance their sensitivity: (i) Resonant-mode enhancement using multiple diamonds, (ii) large-momentum-transfer (LMT) techniques to increase arm separation within the interferometer, and (iii) very-long baseline schemes that increase the distance between the two interferometers. Both resonant-mode enhancement and LMT techniques result in a greater number of light pulses, making high pulse fidelity during atom-light interactions imperative. At the same time, increasing the number of diamonds in vertical configurations leads to taller atomic fountains, which consequently reduces the available distance between interferometers. As a result, the number of diamonds, LMT pulses, and the fountain height are interdependent parameters that must be carefully balanced. In this work, we present optimal configurations for multi-diamond geometries in resonant mode, explicitly accounting for the spatial extent of a single interferometer, considering constraints imposed by the baseline dimensions and atomic losses due to imperfect pulses. For this optimization, we numerically scan the relevant parameters such as initial position and momentum of the atomic cloud, transferred momenta, and number of loops. For each parameter set, we verify whether the imposed conditions are met and evaluate the resulting sensitivities to identify optimal configurations. We provide practical analytical relations to estimate the optimal number of pulses that should be applied. Many proposals beyond demonstrator experiments require pulse numbers that demand efficiencies not yet demonstrated with state-of-the-art momentum transfer techniques. As a result, the observed sensitivity falls short of expectations—an effect caused by both arm separation and atom loss per pulse—highlighting the urgent need for research aimed at improving pulse fidelities.

arXiv:2506.09511•Quantum Science and Technology•Aug 27, 2025•3 citations

Quantum limited measurements in gravitational wave detectors

Andrew R. Wade

Gravitational waves manifest as a time varying straining of space: they arise from the accelerating motions of large bodies of mass and propagate across the universe at the speed of light as ripples in the fabric of space-time, a fleetingly weak effect so far eluding direct detection. The detection of gravitation waves is expected to yield a rich vein to observational astronomy, complementing existing electromagnetic surveys and revealing a hitherto unexplored range of phenomena. First generation interferometric gravitational wave detectors, notably Enhanced LIGO, achieved strain sensitivities of one part in ten to power twenty-one per square-root-Hertz at 100 Hz with an expected detection rate of 2-3 events per year. Commissioning of a new generation of Advanced LIGO interferometric detectors has concluded recently with a resultant ten-fold sensitivity improvement. Overall their potential event detection space has increased by a factor of 1000. The quantum nature of light within these detectors now limits their sensitivity over most of their frequency range. This quantum noise limit is driven by the vacuum quadrature fluctuations propagated through their open detection ports and represents a fundamental noise floor to their strain sensitivity. This thesis addresses two distinct approaches to quantum noise improvement for future upgrades to advanced detectors. The first addresses the issue of quantum noise by adopting a quantum non-demolition approach to detector readout variables, the so-called `speed-meter’ design. Such a modified instrument samples test mass momentum, a quantity for which time separated measurements commute and are therefore not bound by Heisenberg-like limits. A novel polarisation-folded sloshing cavity type speed-meter is proposed where readout fields are stored and delayed in the orthogonal polarisation of the interferometer’s arms cavities. Here frequency dependence is selected to cancel position like measurements so that only test mass momentum information remains. A quantum noise propagation model is developed and a sensitivity performance is demonstrated that beats the standard quantum limit below 100 Hz over a broad range of frequencies. A second approach to achieve quantum noise enhancement in advanced detectors involves injection of quadrature-squeezed states in the place of vacuum. This dissertation details the development of a prototype squeezed vacuum source suitable to the demanding enhancement requirements for an Advanced LIGO squeezing installation. The construction of a doubly resonant, bow-tie cavity source is presented. This employs a novel monolithic all-glass cavity construction and is vacuum compatible. This design demonstrates the viability of building a cavity using optical contacting as a construction technique for attaching mounting prisms to highly polished fused-silica breadboards. Such a design can be expected to have excellent length noise stability, provide low intrinsic phase noise and would be suitable to mount on seismic isolation stages within the LIGO vacuum envelope. Further, the travelling wave cavity design should provide excellent 50 dB intrinsic backscatter isolation. We demonstrate the first operation of such a complex non-linear device under vacuum, producing 8.6 dB of measured vacuum squeezing down to 10 Hz across the advanced LIGO ‘audio-band’ detection range.

•Jan 1, 2016•1 citation

Atom Interferometry in an Optical Cavity

Paul Hamilton, Matt Jaffe, Justin M. Brown +3 more

We propose and demonstrate a new scheme for atom interferometry, using light pulses inside an optical cavity as matter wave beam splitters. The cavity provides power enhancement, spatial filtering, and a precise beam geometry, enabling new techniques such as low power beam splitters (<100 μW), large momentum transfer beam splitters with modest power, or new self-aligned interferometer geometries utilizing the transverse modes of the optical cavity. As a first demonstration, we obtain Ramsey-Raman fringes with >75% contrast and measure the acceleration due to gravity, g, to 60 μg/sqrt[Hz] resolution in a Mach-Zehnder geometry. We use >10(7) cesium atoms in the compact mode volume (600 μm 1/e(2) waist) of the cavity and show trapping of atoms in higher transverse modes. This work paves the way toward compact, high sensitivity, multiaxis interferometry.

arXiv:1409.7130•Physical Review Letters•Mar 11, 2015•113 citations
Atom interferometers employing optical cavities to enhance the beam splitter pulses promise significant advances in science and technology, notably for future gravitational wave detectors. Long cavities, on the scale of hundreds of meters, have been proposed in experiments aiming to become demonstrators for gravitational wave detection at frequencies below 1 Hz, where laser interferometers, such as LIGO, have poor sensitivity. Our group at the Birmingham Institute of Gravitational Wave Astronomy has explored the fundamental limitations of two-mirror cavities for atomic beam splitting, and established upper bounds on the temperature of the atomic ensemble as a function of cavity length and three design parameters: the cavity ggg-factor, the bandwidth, and the optical suppression factor of the first and second order spatial modes. A lower bound to the cavity bandwidth which avoids elongation of the interaction time and maximizes power enhancement was found. An upper limit to cavity length is also found for symmetric two-mirror cavities. These key limitations impact the feasibility of long-baseline detectors, which suffer from a naturally larger bandwidth and worse optical suppression of higher order optical modes. Our findings will aid the design of current and future experiments using this technology, such as the MIGA experiment in Bordeaux. In the future we aim to fully model the effect that the imperfect optical wavefronts have on the atomic transitions.
Atom interferometers employing optical cavities to enhance the beam splitter pulses promise significant advances in science and technology, notably for future gravitational wave detectors. Long cavities, on the scale of hundreds of meters, have been proposed in experiments aiming to observe gravitational waves with frequencies below 1 Hz, where laser interferometers, such as LIGO, have poor sensitivity. Alternatively, short cavities have also been proposed for enhancing the sensitivity of more portable atom interferometers. We explore the fundamental limitations of two-mirror cavities for atomic beam splitting, and establish upper bounds on the temperature of the atomic ensemble as a function of cavity length and three design parameters: the cavity ggg factor, the bandwidth, and the optical suppression factor of the first and second order spatial modes. A lower bound to the cavity bandwidth is found which avoids elongation of the interaction time and maximizes power enhancement. An upper limit to cavity length is found for symmetric two-mirror cavities, restricting the practicality of long baseline detectors. For shorter cavities, an upper limit on the beam size was derived from the geometrical stability of the cavity. These findings aim to aid the design of current and future cavity-assisted atom interferometers.
Atom interferometers employing optical cavities to enhance the beam splitter pulses promise significant advances in science and technology, notably for future gravitational wave detectors. Long cavities, on the scale of hundreds of meters, have been proposed in experiments aiming to observe gravitational waves with frequencies below 1 Hz, where laser interferometers, such as LIGO, have poor sensitivity. Alternatively, short cavities have also been proposed for enhancing the sensitivity of more portable atom interferometers.We explore the fundamental limitations of two-mirror cavities for atomic beam splitting, and establish upper bounds on the temperature of the atomic ensemble as a function of cavity length and three design parameters: the cavity g factor, the bandwidth, and the optical suppression factor of the first and second order spatial modes. A lower bound to the cavity bandwidth is found which avoids elongation of the interaction time and maximizes power enhancement. An upper limit to cavity length is found for symmetric two-mirror cavities, restricting the practicality of long baseline detectors. For shorter cavities, an upper limit on the beam size was derived from the geometrical stability of the cavity. These findings aim to aid the design of current and future cavity-assisted atom interferometers.
Abstract Large-scale atom interferometers promise unrivaled strain sensitivity to mid-band gravitational waves, and will probe a new parameter space in the search for ultra-light scalar dark matter. These proposals require gradiometry with kilometer-scale baselines, a momentum separation above 104ℏk between interferometer arms, and optical transitions to long-lived clock states to reach the target sensitivities. Prohibitively high optical power and wavefront flatness requirements have thus far limited the maximum achievable momentum splitting. Here we propose a scheme for optical cavity enhanced atom interferometry, using circulating, spatially resolved pulses, and intracavity frequency modulation to meet these requirements. We present parameters for the realization of 20 kW circulating pulses in a 1 km interferometer enabling 104ℏk splitting on the 698 nm clock transition in 87Sr. This scheme addresses the presently insurmountable laser power requirements and is feasible in the context of a kilometer-scale atom interferometer facility.
Abstract Currently planned and constructed terrestrial detectors for gravitational waves and dark matter based on differential light-pulse atom interferometry are designed around three primary strategies to enhance their sensitivity: (i) Resonant-mode enhancement using multiple diamonds, (ii) large-momentum-transfer (LMT) techniques to increase arm separation within the interferometer, and (iii) very-long baseline schemes that increase the distance between the two interferometers. Both resonant-mode enhancement and LMT techniques result in a greater number of light pulses, making high pulse fidelity during atom-light interactions imperative. At the same time, increasing the number of diamonds in vertical configurations leads to taller atomic fountains, which consequently reduces the available distance between interferometers. As a result, the number of diamonds, LMT pulses, and the fountain height are interdependent parameters that must be carefully balanced. In this work, we present optimal configurations for multi-diamond geometries in resonant mode, explicitly accounting for the spatial extent of a single interferometer, considering constraints imposed by the baseline dimensions and atomic losses due to imperfect pulses. For this optimization, we numerically scan the relevant parameters such as initial position and momentum of the atomic cloud, transferred momenta, and number of loops. For each parameter set, we verify whether the imposed conditions are met and evaluate the resulting sensitivities to identify optimal configurations. We provide practical analytical relations to estimate the optimal number of pulses that should be applied. Many proposals beyond demonstrator experiments require pulse numbers that demand efficiencies not yet demonstrated with state-of-the-art momentum transfer techniques. As a result, the observed sensitivity falls short of expectations—an effect caused by both arm separation and atom loss per pulse—highlighting the urgent need for research aimed at improving pulse fidelities.
Gravitational waves manifest as a time varying straining of space: they arise from the accelerating motions of large bodies of mass and propagate across the universe at the speed of light as ripples in the fabric of space-time, a fleetingly weak effect so far eluding direct detection. The detection of gravitation waves is expected to yield a rich vein to observational astronomy, complementing existing electromagnetic surveys and revealing a hitherto unexplored range of phenomena. First generation interferometric gravitational wave detectors, notably Enhanced LIGO, achieved strain sensitivities of one part in ten to power twenty-one per square-root-Hertz at 100 Hz with an expected detection rate of 2-3 events per year. Commissioning of a new generation of Advanced LIGO interferometric detectors has concluded recently with a resultant ten-fold sensitivity improvement. Overall their potential event detection space has increased by a factor of 1000. The quantum nature of light within these detectors now limits their sensitivity over most of their frequency range. This quantum noise limit is driven by the vacuum quadrature fluctuations propagated through their open detection ports and represents a fundamental noise floor to their strain sensitivity. This thesis addresses two distinct approaches to quantum noise improvement for future upgrades to advanced detectors. The first addresses the issue of quantum noise by adopting a quantum non-demolition approach to detector readout variables, the so-called `speed-meter’ design. Such a modified instrument samples test mass momentum, a quantity for which time separated measurements commute and are therefore not bound by Heisenberg-like limits. A novel polarisation-folded sloshing cavity type speed-meter is proposed where readout fields are stored and delayed in the orthogonal polarisation of the interferometer’s arms cavities. Here frequency dependence is selected to cancel position like measurements so that only test mass momentum information remains. A quantum noise propagation model is developed and a sensitivity performance is demonstrated that beats the standard quantum limit below 100 Hz over a broad range of frequencies. A second approach to achieve quantum noise enhancement in advanced detectors involves injection of quadrature-squeezed states in the place of vacuum. This dissertation details the development of a prototype squeezed vacuum source suitable to the demanding enhancement requirements for an Advanced LIGO squeezing installation. The construction of a doubly resonant, bow-tie cavity source is presented. This employs a novel monolithic all-glass cavity construction and is vacuum compatible. This design demonstrates the viability of building a cavity using optical contacting as a construction technique for attaching mounting prisms to highly polished fused-silica breadboards. Such a design can be expected to have excellent length noise stability, provide low intrinsic phase noise and would be suitable to mount on seismic isolation stages within the LIGO vacuum envelope. Further, the travelling wave cavity design should provide excellent 50 dB intrinsic backscatter isolation. We demonstrate the first operation of such a complex non-linear device under vacuum, producing 8.6 dB of measured vacuum squeezing down to 10 Hz across the advanced LIGO ‘audio-band’ detection range.
We propose and demonstrate a new scheme for atom interferometry, using light pulses inside an optical cavity as matter wave beam splitters. The cavity provides power enhancement, spatial filtering, and a precise beam geometry, enabling new techniques such as low power beam splitters (<100 μW), large momentum transfer beam splitters with modest power, or new self-aligned interferometer geometries utilizing the transverse modes of the optical cavity. As a first demonstration, we obtain Ramsey-Raman fringes with >75% contrast and measure the acceleration due to gravity, g, to 60 μg/sqrt[Hz] resolution in a Mach-Zehnder geometry. We use >10(7) cesium atoms in the compact mode volume (600 μm 1/e(2) waist) of the cavity and show trapping of atoms in higher transverse modes. This work paves the way toward compact, high sensitivity, multiaxis interferometry.