Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE/LEOS Summer Topical Meetings

Time-Domain Measurement of Continuous-Variable Entanglement Using Temporally Shaped Local Oscillator Pulses

Ami Shinjo, Yujiro Eto, Takuya Hirano

Published Jul 1, 2018• 0 citations
Publisher

Abstract

We demonstrated time-domain measurement and frequency domain measurement of continuous-variable (CV) entanglement with pulsed light source and waveguides. The experiment with pulsed light source has difficulty in temporal mode matching between the entangled beams and local oscillator (LO) beams. To break through this difficulty, we shorten the duration of LO pulse by optical parametric amplification (OPA) in a waveguide. We generated entanglement that satisfied EPR-Reid criterion in the time domain measurement.

DOI
10.1109/phosst.2018.8456728

Related papers

Observation of strong continuous-variable Einstein-Podolsky-Rosen entanglement using shaped local oscillators

Ami Shinjo, Naoyuki Hashiyama, Akane Koshio +2 more

The continuous-variable (CV) Einstein-Podolsky-Rosen (EPR) paradox and steering are demonstrated using a pulsed light source and waveguides. We shorten the duration of the local oscillator (LO) pulse by using parametric amplification to improve the temporal mode-matching between the entangled pulse and the LO pulse. After correcting for the amplifier noise, the product of the measured conditional variance of the quadrature-phase amplitudes is 0.74 < 1, which satisfies the EPR-Reid criterion.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 24, 2016•2 citations

Pulse-resolved measurement of continuous-variable Einstein-Podolsky-Rosen entanglement with shaped local oscillators

Ami Shinjo, Yujiro Eto, Takuya Hirano

We report an experimental demonstration of the continuous-variable Einstein-Podolsky-Rosen (EPR) paradox and quantum steering using a pulsed light source and nonlinear optical waveguides. In this pulsed light source experiment, time-domain measurements were performed in which one measured value of the quadrature phase amplitude of the light field was independently obtained for each pulse. This independence is useful for application to quantum information processing and fundamental physics. To realize time-domain measurements, in-house built homodyne detectors were used to detect individual pulses. In addition, to improve the temporal-mode matching between the local oscillator (LO) and entangled pulse, the duration of the LO pulse was shortened by single-pass optical parametric amplification. The product of the conditional variances of the quadrature amplitudes was 0.82 ± 0.09 < 1, which satisfies the condition for realization of the EPR paradox and quantum steering.

Optics Express•Jun 11, 2019•7 citations

Complete temporal mode analysis in pulse-pumped fiber-optical parametric amplifier for continuous variable entanglement generation

Xueshi Guo, Nannan Liu, Xiaoying Li +1 more

Mode matching plays an important role in measuring the continuous variable entanglement. For the signal and idler twin beams generated by a pulse pumped fiber optical parametric amplifier (FOPA), the spatial mode matching is automatically achieved in single mode fiber, but the temporal mode property is complicated because it is highly sensitive to the dispersion and the gain of the FOPA. We study the temporal mode structure and derive the input-output relation for each temporal mode of signal and idler beams after decomposing the joint spectral function of twin beams with the singular-value decomposition method. We analyze the measurement of the quadrature-amplitude entanglement, and find mode matching between the multi-mode twin beams and the local oscillators of homodyne detection systems is crucial to achieve a high degree of entanglement. The results show that the noise contributed by the temporal modes nonorthogonal to local oscillator may be much larger than the vacuum noise, so the mode mis-match can not be accounted for by merely introducing an effective loss. Our study will be useful for developing a source of high quality continuous variable entanglement by using the FOPA.

Optics Express•Nov 2, 2015•35 citations

Direct Temporal Mode Measurement for the Characterization of Temporally Multiplexed High Dimensional Quantum Entanglement in Continuous Variables

Nan Huo, Yuhong Liu, Jiamin Li +6 more

Field-orthogonal temporal mode analysis of optical fields has recently been developed for a new framework of quantum information science. However, so far, the exact profiles of the temporal modes are not known, which makes it difficult to achieve mode selection and demultiplexing. Here, we report a novel method that measures directly the exact form of the temporal modes. This, in turn, enables us to make mode-orthogonal homodyne detection with mode-matched local oscillators. We apply the method to a pulse-pumped, specially engineered fiber parametric amplifier and demonstrate temporally multiplexed multidimensional quantum entanglement of continuous variables in telecom wavelength. The temporal mode characterization technique can be generalized to other pulse-excited systems to find their eigenmodes for multiplexing in the temporal domain.

arXiv:1910.09102•Physical Review Letters•May 27, 2020•30 citations

Time-domain measurement of continuous-variable entanglement using temporally shaped local oscillator pulses

Ami Shinjo

The International Commission for Optics•May 16, 2017•0 citations

Generation of continuous variable quantum entanglement using a fiber optical parametric amplifier

Xueshi Guo, Nannan Liu, Yuhong Liu +2 more

We demonstrate the experimental generation of quadrature amplitude entanglement in the 1550 nm band by using a fiber optical parametric amplifier. The measured noise variances of the difference and sum of the quadrature amplitudes of the pulsed signal and idler twin beams fall below the shot noise limit by about 1 and 0.8 dB (4.2 and 3.6 dB after the correction for efficiency), respectively, showing that the inseparability criterion of Einstein-Podolsky-Rosen entanglement I<2 is satisfied. Our investigation reveals that the quality of the measured entanglement can be further improved by increasing the transmission efficiency of the twin beams and by optimizing the temporal mode matching of the two sets of homodyne detection systems.

Optics Letters•Feb 1, 2016•24 citations
We demonstrated time-domain measurement and frequency domain measurement of continuous-variable (CV) entanglement with pulsed light source and waveguides. The experiment with pulsed light source has difficulty in temporal mode matching between the entangled beams and local oscillator (LO) beams. To break through this difficulty, we shorten the duration of LO pulse by optical parametric amplification (OPA) in a waveguide. We generated entanglement that satisfied EPR-Reid criterion in the time domain measurement.
We report an experimental demonstration of the continuous-variable Einstein-Podolsky-Rosen (EPR) paradox and quantum steering using a pulsed light source and nonlinear optical waveguides. In this pulsed light source experiment, time-domain measurements were performed in which one measured value of the quadrature phase amplitude of the light field was independently obtained for each pulse. This independence is useful for application to quantum information processing and fundamental physics. To realize time-domain measurements, in-house built homodyne detectors were used to detect individual pulses. In addition, to improve the temporal-mode matching between the local oscillator (LO) and entangled pulse, the duration of the LO pulse was shortened by single-pass optical parametric amplification. The product of the conditional variances of the quadrature amplitudes was 0.82 ± 0.09 < 1, which satisfies the condition for realization of the EPR paradox and quantum steering.
Mode matching plays an important role in measuring the continuous variable entanglement. For the signal and idler twin beams generated by a pulse pumped fiber optical parametric amplifier (FOPA), the spatial mode matching is automatically achieved in single mode fiber, but the temporal mode property is complicated because it is highly sensitive to the dispersion and the gain of the FOPA. We study the temporal mode structure and derive the input-output relation for each temporal mode of signal and idler beams after decomposing the joint spectral function of twin beams with the singular-value decomposition method. We analyze the measurement of the quadrature-amplitude entanglement, and find mode matching between the multi-mode twin beams and the local oscillators of homodyne detection systems is crucial to achieve a high degree of entanglement. The results show that the noise contributed by the temporal modes nonorthogonal to local oscillator may be much larger than the vacuum noise, so the mode mis-match can not be accounted for by merely introducing an effective loss. Our study will be useful for developing a source of high quality continuous variable entanglement by using the FOPA.
Field-orthogonal temporal mode analysis of optical fields has recently been developed for a new framework of quantum information science. However, so far, the exact profiles of the temporal modes are not known, which makes it difficult to achieve mode selection and demultiplexing. Here, we report a novel method that measures directly the exact form of the temporal modes. This, in turn, enables us to make mode-orthogonal homodyne detection with mode-matched local oscillators. We apply the method to a pulse-pumped, specially engineered fiber parametric amplifier and demonstrate temporally multiplexed multidimensional quantum entanglement of continuous variables in telecom wavelength. The temporal mode characterization technique can be generalized to other pulse-excited systems to find their eigenmodes for multiplexing in the temporal domain.
We demonstrate the experimental generation of quadrature amplitude entanglement in the 1550 nm band by using a fiber optical parametric amplifier. The measured noise variances of the difference and sum of the quadrature amplitudes of the pulsed signal and idler twin beams fall below the shot noise limit by about 1 and 0.8 dB (4.2 and 3.6 dB after the correction for efficiency), respectively, showing that the inseparability criterion of Einstein-Podolsky-Rosen entanglement I<2 is satisfied. Our investigation reveals that the quality of the measured entanglement can be further improved by increasing the transmission efficiency of the twin beams and by optimizing the temporal mode matching of the two sets of homodyne detection systems.