IEEE Electronic Components and Technology Conference (ECTC)

Integration of Chip-Scale SERF Atomic Magnetometers for Magnetoencephalography Measurement

Guoliang Li, Jintang Shang, Yu Ji, Lin Lü, Zhihua Pan

Published May 1, 2018• 1 citation
Publisher

Abstract

This paper presents a novel scheme on the integration of chip-scale SERF magnetometer using a vertical-cavity surface-emitting laser(VCSEL) as pumping and detecting laser. The fabrication and integration process of the whole system based on stacking PCB boards consist of VCSEL, optical components, rubidium vapor cell, photo-detector, three axis Helmholtz coils. By calculation and measurement, it was found that the module is designed with a minimum output power of 0.15mW and a competitive volume of 1.4×1.4×2.5cm3. Experiments show that the sensitivity of chip-scale SERF magnetometer based on VCSEL is around 1.87pT/Hz1/2in magnetic shield environment, the integration and miniaturization design process of the magnetometer can be empolyed for magnetoencephalography(MEG) measurement.

DOI
10.1109/ectc.2018.00124

Related papers

System integration of a SERF atomic magnetometer on a glass wafer substrate

Yu Ji, Jintang Shang, Qi Gan +1 more

High sensitive SERF(spin-exchange-relaxation-free) atomic magnetometers play an important role in many fields including geophysical mapping, space science, nuclear magnetic resonance, health care and perimeter and remote monitoring. This paper presents a novel approach for the system integration of a SERF atomic magnetometer. First of all, Rb vapor cell integrated with micro heater and Helmholtz coils was selected as physic part of the system and the vapor cell was characterized by pressure broadening effect to analyze nitrogen buffer gas pressure in the vapor cell. Then optical module including laser, micro-lens to collimate light beam emitting from the laser, quarter-wave plate to circularly polarize laser beam was taken as optical pumping and probing source simultaneously, and the interaction of circularly polarized laser beam with rubidium atoms was detected by silicon PIN photo-detectors. At last, Laser module, physics part of the system and silicon PIN photo-detector were integrated on a glass wafer substrate benefiting from the characteristics of non-magnetic material and good flatness, based on the integrated SERF atomic magnetometer, weak magnetic field could be measured. Results demonstrate that the SERF atomic magnetometer is integrated successfully and could be used for the detection of weak magnetic field.

International Conference on Electronic Packaging Technology (ICEPT)•Aug 1, 2015•1 citation

Wafer-level optical packaging for chip-scale atomic magnetometers

Qi Gan, Lei Wu, Yu Ji +1 more

A wafer-level optical package solution for chip-scale atomic magnetometers is presented, which is based on microelectronic fabrication process on a 4 inch wafer. A module is fabricated following the process. By measuring the intensity of the light, it is indicated that the quality of parallelism and polarizability of the laser beam from a Vertical Cavity Surface Emitting Laser (VCSEL) in the module are acceptable. The frequency of the VCSEL is locked to D1 line of Rubidium through proper adjustment of temperature and driving current. The module is employed in an atomic magnetometer which operates in Mz configuration for the detection the strength of magnetic fields. Results show the feasibility of the package in a magnetometer system.

International Conference on Electronic Packaging Technology (ICEPT)•Aug 1, 2015•2 citations

Microfabricated SERF Atomic Magnetometers for Measurement of Weak Magnetic Field

Kangni Liu, Jintang Shang, Jin Zhang +4 more

This paper introduces measurement of weak magnetic field using a novel design of chip-scale Spin Exchange Relaxation Free (SERF) atomic magnetometer based on a microfabricated Rubidium (Rb) vapor cell. The sensor, which integrates a micro-fabricated Rb vapor cell, a heater and related components, is fabricated by stacking printed circuit boards (PCB) and Micro Electro Mechanical Systems (MEMS) process technology. During the experiments, the noise of the measurement using the atomic magnetometer was obtained. In addition, a test of the simulated magnetic field was performed in a shielding cylinder, and the signal of the simulated magnetic field about 100 pT at 1.2 Hz was measured. The signal is processed by the software using a notch filter to suppress the Direct Current (DC) noise and 50Hz noise. This paper provides a novel micro-fabricated device for detecting weak magnetic field.

IEEE Electronic Components and Technology Conference (ECTC)•Jun 1, 2020•3 citations

Performance Characterization and Optimization of a Miniaturized SERF Atomic Magnetometer via Tunable Laser Power

Peng Shi, Chen Zuo, Qisong Li +1 more

Spin-exchange relaxation-free (SERF) atomic magnetometers have emerged as highly promising candidates for ultra-weak magnetic field detection, particularly in biomagnetic imaging, owing to their exceptional sensitivity, amenability to miniaturization, and near-room-temperature operation. While current miniaturized magnetometers typically employ laser chips with fixed optical power, the quantitative impact of laser power on critical performance metrics remains to be fully elucidated. This study systematically investigates the influence of laser power on sensitivity, bandwidth, and dynamic range by incorporating considerations of power broadening, saturation absorption, and noise constraints. A miniaturized probe, integrated with an actively controlled vertical-cavity surface-emitting laser (VCSEL), was developed for experimental validation. Theoretical and experimental results consistently demonstrate that as optical power increases, sensitivity exhibits a non-monotonic dependence, whereas both bandwidth and dynamic range manifest a monotonic upward trend, aligning well with theoretical simulations. The optimized sensor achieved a peak sensitivity of 16 fT/√Hz at 300 μW, while the bandwidth and dynamic range reached 230 Hz and ±5.4 nT at 500 μW, respectively. This work establishes a robust theoretical and experimental framework for the comprehensive performance optimization of laser-integrated miniaturized atomic magnetometers.

Sensors•Mar 23, 2026•0 citations

Ultrasensitive SERF atomic magnetometer with a miniaturized hybrid vapor cell

Yintao Ma, Yao Chen, Mingzhi Yu +8 more

Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.

Microsystems & Nanoengineering•Aug 30, 2024•74 citations

Integration of the SERF Magnetometer and the Mz Magnetometer Using Micro-Fabricated Alkali Vapor Cell

Jin Zhang, Jintang Shang, Guoliang Li +4 more

With the continuous improvement of weak magnetic detection technology, there has been a growing trend towards more compact and integrated magnetometer. The SERF magnetometer and the Mz magnetometer have many common features in operation. Therefore, we design a new kind of miniaturized atomic sensors to integrate the SERF magnetometer and the Mz magnetometer based on micro-fabricated alkali vapor cell. The sensor structure consists of alkali vapor cell, three-axis magnetic field coils, heating module and optical module. This small size sensor has the potential to achieve a portable multi-function device.

IEEE Electronic Components and Technology Conference (ECTC)•May 1, 2018•1 citation
This paper presents a novel scheme on the integration of chip-scale SERF magnetometer using a vertical-cavity surface-emitting laser(VCSEL) as pumping and detecting laser. The fabrication and integration process of the whole system based on stacking PCB boards consist of VCSEL, optical components, rubidium vapor cell, photo-detector, three axis Helmholtz coils. By calculation and measurement, it was found that the module is designed with a minimum output power of 0.15mW and a competitive volume of 1.4×1.4×2.5cm3. Experiments show that the sensitivity of chip-scale SERF magnetometer based on VCSEL is around 1.87pT/Hz1/2in magnetic shield environment, the integration and miniaturization design process of the magnetometer can be empolyed for magnetoencephalography(MEG) measurement.
High sensitive SERF(spin-exchange-relaxation-free) atomic magnetometers play an important role in many fields including geophysical mapping, space science, nuclear magnetic resonance, health care and perimeter and remote monitoring. This paper presents a novel approach for the system integration of a SERF atomic magnetometer. First of all, Rb vapor cell integrated with micro heater and Helmholtz coils was selected as physic part of the system and the vapor cell was characterized by pressure broadening effect to analyze nitrogen buffer gas pressure in the vapor cell. Then optical module including laser, micro-lens to collimate light beam emitting from the laser, quarter-wave plate to circularly polarize laser beam was taken as optical pumping and probing source simultaneously, and the interaction of circularly polarized laser beam with rubidium atoms was detected by silicon PIN photo-detectors. At last, Laser module, physics part of the system and silicon PIN photo-detector were integrated on a glass wafer substrate benefiting from the characteristics of non-magnetic material and good flatness, based on the integrated SERF atomic magnetometer, weak magnetic field could be measured. Results demonstrate that the SERF atomic magnetometer is integrated successfully and could be used for the detection of weak magnetic field.
A wafer-level optical package solution for chip-scale atomic magnetometers is presented, which is based on microelectronic fabrication process on a 4 inch wafer. A module is fabricated following the process. By measuring the intensity of the light, it is indicated that the quality of parallelism and polarizability of the laser beam from a Vertical Cavity Surface Emitting Laser (VCSEL) in the module are acceptable. The frequency of the VCSEL is locked to D1 line of Rubidium through proper adjustment of temperature and driving current. The module is employed in an atomic magnetometer which operates in Mz configuration for the detection the strength of magnetic fields. Results show the feasibility of the package in a magnetometer system.
This paper introduces measurement of weak magnetic field using a novel design of chip-scale Spin Exchange Relaxation Free (SERF) atomic magnetometer based on a microfabricated Rubidium (Rb) vapor cell. The sensor, which integrates a micro-fabricated Rb vapor cell, a heater and related components, is fabricated by stacking printed circuit boards (PCB) and Micro Electro Mechanical Systems (MEMS) process technology. During the experiments, the noise of the measurement using the atomic magnetometer was obtained. In addition, a test of the simulated magnetic field was performed in a shielding cylinder, and the signal of the simulated magnetic field about 100 pT at 1.2 Hz was measured. The signal is processed by the software using a notch filter to suppress the Direct Current (DC) noise and 50Hz noise. This paper provides a novel micro-fabricated device for detecting weak magnetic field.
Spin-exchange relaxation-free (SERF) atomic magnetometers have emerged as highly promising candidates for ultra-weak magnetic field detection, particularly in biomagnetic imaging, owing to their exceptional sensitivity, amenability to miniaturization, and near-room-temperature operation. While current miniaturized magnetometers typically employ laser chips with fixed optical power, the quantitative impact of laser power on critical performance metrics remains to be fully elucidated. This study systematically investigates the influence of laser power on sensitivity, bandwidth, and dynamic range by incorporating considerations of power broadening, saturation absorption, and noise constraints. A miniaturized probe, integrated with an actively controlled vertical-cavity surface-emitting laser (VCSEL), was developed for experimental validation. Theoretical and experimental results consistently demonstrate that as optical power increases, sensitivity exhibits a non-monotonic dependence, whereas both bandwidth and dynamic range manifest a monotonic upward trend, aligning well with theoretical simulations. The optimized sensor achieved a peak sensitivity of 16 fT/√Hz at 300 μW, while the bandwidth and dynamic range reached 230 Hz and ±5.4 nT at 500 μW, respectively. This work establishes a robust theoretical and experimental framework for the comprehensive performance optimization of laser-integrated miniaturized atomic magnetometers.
Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.
With the continuous improvement of weak magnetic detection technology, there has been a growing trend towards more compact and integrated magnetometer. The SERF magnetometer and the Mz magnetometer have many common features in operation. Therefore, we design a new kind of miniaturized atomic sensors to integrate the SERF magnetometer and the Mz magnetometer based on micro-fabricated alkali vapor cell. The sensor structure consists of alkali vapor cell, three-axis magnetic field coils, heating module and optical module. This small size sensor has the potential to achieve a portable multi-function device.