Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

European Frequency and Time Forum

Raman-Ramsey CPT with a grating magneto-optical trap

Rachel Elvin, Gregory W. Hoth, Michael W. Wright, J. P. McGilligan, Aidan S. Arnold, Paul F. Griffin, Erling Riis

Published Apr 1, 2018• 4 citations
Publisher

Abstract

We describe an experiment which combines cold87Rb atoms from a grating magneto-optical trap (GMOT) with Lin±Lin coherent population trapping (CPT) and pulsed Ramsey interrogation. The bichromatic fields required for Lin±Lin are generated by combining light from a single external cavity diode laser (ECDL) with an electro-optic modulator (EOM) and an acousto-optic modulator (AOM). With this laser system and the GMOT, we are able to produce Raman-Ramsey fringes using either the F' = 1 or the F' = 2 excited states of the87Rb Di line. As a step towards realising a frequency standard based on the GMOT, we measure the Ramsey fringe amplitude as a function of the magnetic bias field and the excited state. We observe dark state interference with F'= 1 and show that this interference is suppressed with F' = 2, as expected from prior work on CPT with87Rb in thermal vapour cells.

DOI
10.1109/eftf.2018.8408998

Related papers

Raman–Ramsey pulsed excitation of coherent population trapping resonances in a 87Rb cell with a buffer gas

V. N. Baryshev, G. V. Osipenko, M. S. Aleinikov +1 more

We report the results of experimental investigation of the Raman – Ramsey method of pulsed excitation of coherent population trapping (CPT) resonances in a rubidium vapour cell filled with a mixture of Ar and Ne buffer gases. For the development of compact quantum microwave frequency standards, this method is an alternative to the pulsed optical pumping method recently implemented using the same rubidium cell. Both methods have advantages over the traditional double radio-optical resonance technique, the main of which is the substantial suppression of the light shift of the clock transition frequency, since the evolution of the coherence of atomic states forming the clock transition occurs in the absence of laser radiation in the cell. The narrow (110 – 240 Hz) Raman – Ramsey resonances are obtained using the scheme of pulsed excitation of CPT resonances on the D 1 lines of the 87 Rb atom with the same linear (lin||lin) polarisations of the bichromatic laser radiation components. The process of optimising the central fringe linewidth, its contrast, and the linewidth-to-contrast ratio is described. The magnetic dependence of the Raman – Ramsey line central fringe linewidth is experimentally investigated.

Quantum Electronics•Mar 1, 2019•6 citations

Progress of Compact CPT Rb Atomic Clock based on Grating Magneto-Optical Trap

Junyi Duan, Xiaochi Liu, Ning Ru +2 more

The combination of coherent population trapping (CPT) physics and grating magneto-optical trap (GMOT) holds a potential of developing the next generation high performance compact atomic clock. In this work, we aim to build a Rb atomic clock that combining double-modulation coherent population trapping (DM-CPT) in GMOT system. In order to maximize the atoms trapped in clock transition, circularly polarization laser beam is replaced by modulated σ+and σ-beam, with which high-contrast and narrow-linewidth CPT signal could be observed. Also the GMOT system is designed for the interrogation of laser-cooled atoms. This work could provide foundation of high performance compact cold-atom CPT clock.

Conference on Precision Electromagnetic Measurements•Aug 1, 2020•0 citations

A cold-atom Ramsey clock with a low volume physics package

Alan Bregazzi, Etienne Batori, Ben Lewis +4 more

We demonstrate a Ramsey-type microwave clock interrogating the 6.835 GHz ground-state transition in cold [Formula: see text]Rb atoms loaded from a grating magneto-optical trap (GMOT) enclosed in an additively manufactured loop-gap resonator microwave cavity. A short-term stability of [Formula: see text] is demonstrated, in reasonable agreement with predictions from the signal-to-noise ratio of the measured Ramsey fringes. The cavity-grating package has a volume of [Formula: see text]67 cm[Formula: see text], ensuring an inherently compact system while the use of a GMOT drastically simplifies the optical requirements for laser cooled atoms. This work is another step towards the realisation of highly compact portable cold-atom frequency standards.

arXiv:2305.02944•Scientific Reports•Jan 9, 2024•23 citations

Towards a compact atomic clock based on coherent population trapping and the grating magneto-optical trap

Erling Riis, Gregory W. Hoth, Rachel Elvin +4 more

The combination of coherent population trapping (CPT) and laser cooled atoms is a promising platform for realizing the next generation of compact atomic frequency references. Towards this goal, we have developed an apparatus based on the grating magneto-optical trap (GMOT) and the high-contrast lin ⊥ lin CPT scheme in order to explore the performance that can be achieved. One important trade-off for cold-atom systems arises from the need to simultaneously maximize the number of cold atoms available for interrogation and the repetition rate of the system. This compromise can be mitigated by recapturing cold atoms from cycle to cycle. Here, we report a quantitative characterization of the cold atom number in the recapture regime for our system, which will enable us to optimize this trade-off. We also report recent measurements of the short-term frequency stability with a short-term Allan deviation of 3 × 10-11/τ up to an averaging time of τ = 10 s.

Optical and Quantum Sensing and Precision Metrology II•Mar 1, 2019•4 citations

Impact of Laser Frequency Noise in Coherent Population Trapping with Cold Atoms

Gregory W. Hoth, Rachel Elvin, Michael W. Wright +7 more

Laser-cooled atoms and coherent population trapping (CPT) are promising tools for realizing a compact microwave frequency reference with excellent stability. To realize a high performance device, it is necessary to understand and minimize all sources of technical noise. Here, we investigate the role of laser frequency noise in cold-atom CPT with an apparatus based on the grating magneto-optical trap (GMOT). We compare the performance of our setup with an external cavity diode laser (ECDL) and a distributed feedback diode laser (DFB). With the DFB, laser frequency noise is one of the dominant noise sources in our system. With the ECDL, it is significantly reduced. We also report frequency stability measurements of our apparatus with a short-term Allan deviation σy(τ) = 3×10-11/√τ up to τ = 10 s.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•1 citation

Exploring Ramsey-coherent population trapping atomic clock realized with pulsed microwave modulated laser

Jing Yang, Yuan Tian, Bozhong Tan +2 more

A scheme for a Ramsey-coherent population trapping (CPT) atomic clock that eliminates the acousto-optic modulator (AOM) is proposed and experimentally studied. Driven by a periodically microwave modulated current, the vertical-cavity surface-emitting laser emits a continuous beam that switches between monochromatic and multichromatic modes. Ramsey-CPT interference has been studied with this mode-switching beam. In eliminating the AOM, which is used to generate pulsed laser in conventional Ramsey-CPT atomic clock, the physics package of the proposed scheme is virtually the same as that of a conventional compact CPT atomic clock, although the resource budget for the electronics will slightly increase as a microwave switch should be added. By evaluating and comparing experimentally recorded signals from the two Ramsey-CPT schemes, the short-term frequency stability of the proposed scheme was found to be 46% better than the scheme with AOM. The experimental results suggest that the implementation of a compact Ramsey-CPT atomic clock promises better frequency stability.

Journal of Applied Physics•Mar 7, 2014•16 citations
We describe an experiment which combines cold87Rb atoms from a grating magneto-optical trap (GMOT) with Lin±Lin coherent population trapping (CPT) and pulsed Ramsey interrogation. The bichromatic fields required for Lin±Lin are generated by combining light from a single external cavity diode laser (ECDL) with an electro-optic modulator (EOM) and an acousto-optic modulator (AOM). With this laser system and the GMOT, we are able to produce Raman-Ramsey fringes using either the F' = 1 or the F' = 2 excited states of the87Rb Di line. As a step towards realising a frequency standard based on the GMOT, we measure the Ramsey fringe amplitude as a function of the magnetic bias field and the excited state. We observe dark state interference with F'= 1 and show that this interference is suppressed with F' = 2, as expected from prior work on CPT with87Rb in thermal vapour cells.
We report the results of experimental investigation of the Raman – Ramsey method of pulsed excitation of coherent population trapping (CPT) resonances in a rubidium vapour cell filled with a mixture of Ar and Ne buffer gases. For the development of compact quantum microwave frequency standards, this method is an alternative to the pulsed optical pumping method recently implemented using the same rubidium cell. Both methods have advantages over the traditional double radio-optical resonance technique, the main of which is the substantial suppression of the light shift of the clock transition frequency, since the evolution of the coherence of atomic states forming the clock transition occurs in the absence of laser radiation in the cell. The narrow (110 – 240 Hz) Raman – Ramsey resonances are obtained using the scheme of pulsed excitation of CPT resonances on the D 1 lines of the 87 Rb atom with the same linear (lin||lin) polarisations of the bichromatic laser radiation components. The process of optimising the central fringe linewidth, its contrast, and the linewidth-to-contrast ratio is described. The magnetic dependence of the Raman – Ramsey line central fringe linewidth is experimentally investigated.
The combination of coherent population trapping (CPT) physics and grating magneto-optical trap (GMOT) holds a potential of developing the next generation high performance compact atomic clock. In this work, we aim to build a Rb atomic clock that combining double-modulation coherent population trapping (DM-CPT) in GMOT system. In order to maximize the atoms trapped in clock transition, circularly polarization laser beam is replaced by modulated σ+and σ-beam, with which high-contrast and narrow-linewidth CPT signal could be observed. Also the GMOT system is designed for the interrogation of laser-cooled atoms. This work could provide foundation of high performance compact cold-atom CPT clock.
We demonstrate a Ramsey-type microwave clock interrogating the 6.835 GHz ground-state transition in cold [Formula: see text]Rb atoms loaded from a grating magneto-optical trap (GMOT) enclosed in an additively manufactured loop-gap resonator microwave cavity. A short-term stability of [Formula: see text] is demonstrated, in reasonable agreement with predictions from the signal-to-noise ratio of the measured Ramsey fringes. The cavity-grating package has a volume of [Formula: see text]67 cm[Formula: see text], ensuring an inherently compact system while the use of a GMOT drastically simplifies the optical requirements for laser cooled atoms. This work is another step towards the realisation of highly compact portable cold-atom frequency standards.
The combination of coherent population trapping (CPT) and laser cooled atoms is a promising platform for realizing the next generation of compact atomic frequency references. Towards this goal, we have developed an apparatus based on the grating magneto-optical trap (GMOT) and the high-contrast lin ⊥ lin CPT scheme in order to explore the performance that can be achieved. One important trade-off for cold-atom systems arises from the need to simultaneously maximize the number of cold atoms available for interrogation and the repetition rate of the system. This compromise can be mitigated by recapturing cold atoms from cycle to cycle. Here, we report a quantitative characterization of the cold atom number in the recapture regime for our system, which will enable us to optimize this trade-off. We also report recent measurements of the short-term frequency stability with a short-term Allan deviation of 3 × 10-11/τ up to an averaging time of τ = 10 s.
Laser-cooled atoms and coherent population trapping (CPT) are promising tools for realizing a compact microwave frequency reference with excellent stability. To realize a high performance device, it is necessary to understand and minimize all sources of technical noise. Here, we investigate the role of laser frequency noise in cold-atom CPT with an apparatus based on the grating magneto-optical trap (GMOT). We compare the performance of our setup with an external cavity diode laser (ECDL) and a distributed feedback diode laser (DFB). With the DFB, laser frequency noise is one of the dominant noise sources in our system. With the ECDL, it is significantly reduced. We also report frequency stability measurements of our apparatus with a short-term Allan deviation σy(τ) = 3×10-11/√τ up to τ = 10 s.
A scheme for a Ramsey-coherent population trapping (CPT) atomic clock that eliminates the acousto-optic modulator (AOM) is proposed and experimentally studied. Driven by a periodically microwave modulated current, the vertical-cavity surface-emitting laser emits a continuous beam that switches between monochromatic and multichromatic modes. Ramsey-CPT interference has been studied with this mode-switching beam. In eliminating the AOM, which is used to generate pulsed laser in conventional Ramsey-CPT atomic clock, the physics package of the proposed scheme is virtually the same as that of a conventional compact CPT atomic clock, although the resource budget for the electronics will slightly increase as a microwave switch should be added. By evaluating and comparing experimentally recorded signals from the two Ramsey-CPT schemes, the short-term frequency stability of the proposed scheme was found to be 46% better than the scheme with AOM. The experimental results suggest that the implementation of a compact Ramsey-CPT atomic clock promises better frequency stability.