Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Measurement of the ratio of the 6P$_{\mathrm{j}}\to $ 7S $_{\mathrm{\raise.5ex\hbox{$\scriptstyle 1$}\kern-.1em/ \kern-.15em\lower.25ex\hbox{$\scriptstyle 2$} }}$ matrix elements in atomic cesium

Amy Damitz, George Toh, Nathan Glotzbach, Jonah Quirk, Ian Stevenson, Jungu Choi, Dan Elliott

Published May 31, 2018• 0 citations
OpenAlex

Related papers

Electric dipole matrix elements for the $6p\ ^2P_J \rightarrow 7s\ ^2S_{1/2}$ transitions in atomic cesium

George Toh, Amy Damitz, Nathan Glotzbach +5 more

Bulletin of the American Physical Society•May 29, 2019•0 citations

Measurement of the radial matrix elements for the 6s 2 S 1 / 2 -> 7p 2 P J transitions in cesium

Amy Damitz, George Toh, Eric Putney +2 more

APS•May 1, 2019•0 citations

Measurement of the 6P 3/2 lifetime of cesium by means of time-resolved spectroscopy technique

E. Campani, Edmondo De Salvo, Giampaolo Gorini

Lettere al nuovo cimento della societa italiana di fisica/Lettere al nuovo cimento•Dec 1, 1980•4 citations

New Manifestation of Atomic Parity Violation in Cesium: A Chiral Optical Gain Induced by Linearly Polarized 6S−7S Excitation

Jocelyne Guéna, Dominique Chauvat, Ph. Jacquier +7 more

We have detected, by using stimulated emission, an atomic parity violation (APV) in the form of a chiral optical gain of a cesium vapor on the 7S-6P(3/2) transition, consecutive to linearly polarized 6S-7S excitation. We demonstrate the validity of this detection method of APV, by presenting a 9% accurate measurement of expected sign and magnitude. We stress several advantages of this new approach which fully exploits the cylindrical symmetry of the setup. Future measurements at the percent level will provide an important cross-check of an existing more precise result obtained by a different method.

arXiv:physics/0210069•Physical Review Letters•Apr 8, 2003•48 citations

Measurement of the Stark shift of the 6s$^{2}$S$_{1/2}$ $\to$ 7p$^{2}$P$_{\mathrm{J}}$ transitions in atomic cesium

George Toh, Dionysis Antypas, Dan Elliott

Bulletin of the American Physical Society•Jun 11, 2015•0 citations

Lasing and suppressed cavity-pulling effect of Cesium active optical clock

Zhichao Xu, Wei Zhuang, Jingbiao Chen

We experimentally demonstrate the collective emission behavior and suppressed cavity-pulling effect of four-level active optical clock with Cesium atoms. Thermal Cesium atoms in a glass cell velocity selective pumped with a 455.5 nm laser operating at 6S$_{1/2}$ to 7P$_{3/2}$ transition are used as lasing medium. Population inverted Cesium atoms between 7S$_{1/2}$ and 6P$_{3/2}$ levels are optical weakly coupled by a pair cavity mirrors working at deep bad-cavity regime with a finesse of 4.3, and the ratio between cavity bandwidth and gain bandwidth is approximately 45. With increased 455.5 nm pumping laser intensity, the output power of cesium active optical clock at 1469.9 nm from 7S$_{1/2}$ level to 6P$_{3/2}$ level shows a threshold and reach a power of 13 $μ$W. Active optical clock would dramatically improve the optical clock stability since the lasing frequency does not follow the cavity length variation exactly, but in a form of suppressed cavity pulling effect. In this letter the cavity pulling effect is measured using a Fabry-Perot interferometer (FPI) to be reduced by a factor of 38.2 and 41.4 as the detuning between the 1469.9 nm cavity length of the Cs active optical clock and the Cs 1469.9 nm transition is set to be 140.8 MHz and 281.6 MHz respectively. The mechanism demonstrated here is of great significance for new generation optical clocks and can be applied to improve the stability of best optical clocks by at least two orders of magnitude.

arXiv:1404.6021•Apr 24, 2014•7 citations
Electric dipole matrix elements for the 6p 2PJ→7s 2S1/26p\ ^2P_J \rightarrow 7s\ ^2S_{1/2}6p 2PJ​→7s 2S1/2​ transitions in atomic cesium
We have detected, by using stimulated emission, an atomic parity violation (APV) in the form of a chiral optical gain of a cesium vapor on the 7S-6P(3/2) transition, consecutive to linearly polarized 6S-7S excitation. We demonstrate the validity of this detection method of APV, by presenting a 9% accurate measurement of expected sign and magnitude. We stress several advantages of this new approach which fully exploits the cylindrical symmetry of the setup. Future measurements at the percent level will provide an important cross-check of an existing more precise result obtained by a different method.
Measurement of the Stark shift of the 6s2^{2}2S1/2_{1/2}1/2​ →\to→ 7p2^{2}2PJ_{\mathrm{J}}J​ transitions in atomic cesium
We experimentally demonstrate the collective emission behavior and suppressed cavity-pulling effect of four-level active optical clock with Cesium atoms. Thermal Cesium atoms in a glass cell velocity selective pumped with a 455.5 nm laser operating at 6S1/2_{1/2}1/2​ to 7P3/2_{3/2}3/2​ transition are used as lasing medium. Population inverted Cesium atoms between 7S1/2_{1/2}1/2​ and 6P3/2_{3/2}3/2​ levels are optical weakly coupled by a pair cavity mirrors working at deep bad-cavity regime with a finesse of 4.3, and the ratio between cavity bandwidth and gain bandwidth is approximately 45. With increased 455.5 nm pumping laser intensity, the output power of cesium active optical clock at 1469.9 nm from 7S1/2_{1/2}1/2​ level to 6P3/2_{3/2}3/2​ level shows a threshold and reach a power of 13 μμμW. Active optical clock would dramatically improve the optical clock stability since the lasing frequency does not follow the cavity length variation exactly, but in a form of suppressed cavity pulling effect. In this letter the cavity pulling effect is measured using a Fabry-Perot interferometer (FPI) to be reduced by a factor of 38.2 and 41.4 as the detuning between the 1469.9 nm cavity length of the Cs active optical clock and the Cs 1469.9 nm transition is set to be 140.8 MHz and 281.6 MHz respectively. The mechanism demonstrated here is of great significance for new generation optical clocks and can be applied to improve the stability of best optical clocks by at least two orders of magnitude.