Achievement of autonomous quantum sensing of gravity at the 10-10 level of stability (Conference Presentation)
Jean Lautier‐Gaud, Vincent Ménoret, Pierre Vermeulen, Fabiola A. Camargo, Fabrice Tardif, Mathieu Corradini, Cédric Majek, Guillaume Stern, Mathieu Guéridon
This paper reports recent remarkable achievements of cold-atom technologies and related operational devices in the area of Quantum Sensing and Metrology. We will present in detail the status of the Absolute Quantum Gravimeter (AQG) that has left the laboratory for geophysical studies. The AQG is an industry-grade commercial gravity sensor which today meets the objective to provide a gravimeter based on atom interferometry with laser-cooled atoms as a mobile turn-key device. We report on an operational stability of continuous absolute measurements of g at the 10-10 level in various types of environment during month-long continuous acquisition periods. The first unit of the AQG has traveled more than 7000 km, so we will comment on the last measurement campaigns and comparisons performed by the AQG. These have in particular validated the repeatability of the measurements at the 10-9 level, the ease of use and the robustness of such technology. This paper will also be the occasion to describe in more details the maturity of several key technologies such as intelligent integrated laser systems that can help Quantum Technologies with cold-atoms taking-off for a wider range of applications in Quantum Computing, Quantum Simulation and Quantum Communication.
This paper reports recent remarkable achievements of cold-atom technologies and related operational devices in the area of Quantum Sensing and Metrology. We will present in detail the status of the Absolute Quantum Gravimeter (AQG) that has left the laboratory for geophysical studies. The AQG is an industry-grade commercial gravity sensor which today meets the objective to provide a gravimeter based on atom interferometry with laser-cooled atoms as a mobile turn-key device. We report on an operational stability of continuous absolute measurements of g at the 10-10 level in various types of environment during month-long continuous acquisition periods. The first unit of the AQG has traveled more than 7000 km, so we will comment on the last measurement campaigns and comparisons performed by the AQG. These have in particular validated the repeatability of the measurements at the 10-9 level, the ease of use and the robustness of such technology. This paper will also be the occasion to describe in more details the maturity of several key technologies such as intelligent integrated laser systems that can help Quantum Technologies with cold-atoms taking-off for a wider range of applications in Quantum Computing, Quantum Simulation and Quantum Communication.
After 30 years of academic research in cold atom sciences, intensive developments are being conducted to improve the compactness and the reliability of experimental set-ups in order to transfer such devices from laboratory-based research to an operational utilization outside of the laboratory. We will present the long-lasting developments that we have been carrying to provide the first industrial cold-atom absolute gravimeter and the first industrial cold-atom atomic clock. We will present in detail the principles of operation and the main features of our instruments. Their performances in terms of sensitivity, stability and accuracy and the latest results they achieved will be reviewed. We will then discuss their use to support other research activities. One of the key technology elements of such instruments that need to be addressed is the laser system used to cool down and manipulate the atoms. A specific focus on our latest developments in this area in terms of performances will be proposed.
Atomic gravimetry measures the gravitional acceleration of an ensemble of identical neutral atoms through the atom interferometry based on Raman two-photon transition, where the Raman lasers are used as “optical ruler" and the identical neutral atoms play the role of test mass and quantum storage of gravity field information. As the novel gravimetry system suffers no mechanical wear and works at a higher repetition rate, atom gravimetry can reach a much better short-term sensitivity than the classical falling-corner-cube counterpart, and the accuracy is reasonably well. Since the very first in-laboratory device built over 30 years ago, atomic gravimetry has matured to a versatile tool that offers both precise and accurate absolute gravity measurement to fundamental research and metrology, such as testing the weak equivalence principle or linking the mass and weight of the test mass in Watt (Kibble) balance. As the current rapid development of compact cold-atom gravimeters, atomic gravimetry is moving out of the laboratory to be used as a quantum enhancement of classical devices in dynamical measurement, such as geophysics survey, inertial navigation and space mission. We review the roadmap for the development of cold-atom absolute gravimetry, highlight recent advances in the dynamical measurement using compact cold atom gravimeters and discuss the associated technological challenges. In the future, with the maturity of its application in dynamical measurement or civil engineering and the innovation in atom interferometry theory, atomic gravimetry could play a more and more important role in our life.
Measuring the acceleration of the Earths gravity g and the gravity gradient simultaneously and at the same location promises to provide enhance information about the distribution of underground masses, especially at shallow depths [1]. Quantum sensors relying on Atom Interferometry with laser cooled-atoms [2,3] is a technology of choice to implement such new sensing capability and an industry-grade demonstrator has been recently developed. We present the performance of the device that has been integrated and discuss its stationary measurement capability, with the demonstration of a resolution below 1E for the measurement of the vertical gravity gradient (1E = 10-9 s-2 = 0.1 Gal/m) and 0.5 Gal for the measurement of g. In order to illustrate the potential for mass balance monitoring and gravity survey we will present a proof-of-principle experiment with realistic masses and measurement durations. The compactness of the instrument and the field-tested technology [4] on which it is based allows to consider the deployment of this new sensor in real environment as a future short-term outcome to investigate both spatial and temporal mass balance in the field. Promising case studies will be discussed, as this type of sensor can sense mass changes that are not detected by gravimeters. [1] G. Pajot, O. de Viron, M. M. Diament, M. F. Lequentrec-Lalancette, V. Mikhailov, Geophysics 73, 123 (2008) [2] R.Geiger, A.Landragin, S.Merlet, F. Pereira Dos Santos, AVS QuantumScience 2, 024702(2020) [3] V. Menoret et al., "Gravity measurements below 109 g with a transportable absolute quantum gravimeter", Nature Scientific Reports, vol. 8, 12300 (2018) [4] A.-K. Cooke, C. Champollion, N. Le Moigne, Geoscientific Instrumentation, Methods and Data Systems Discussions 2020, 1 (2020)
Accurate and stable acceleration due to gravity measurements are critical for mapping spatial and temporal density variation of Earth's subsurface, precision inertial navigation, advanced metrology, detecting underground structures, and many other applications.For precise measurement of gravity, absolute quantum gravimeter (AQG) exploits atomic matter wave interference to achieve exceptional sensitivity (≤ 1 μGal) as well as offering longterm stability and mitigates of mechanical drifts.Gravity measurement with an AQG involves several processes such as cooling and trapping Rubidium-87 ( 87 Rb) atoms in a magneto-optical trap (MOT), followed by optical molasses and polarization gradient cooling (PGC), state preparation, atom-interferometry, and population detection.The operational sequences in these processes demand extremely precise event triggering and synchronized instrument operation with sub-microsecond accuracy.Since the sensitivity and accuracy of gravity measurements with an AQG are highly dependent on timing precision, any deviation in the sequence can introduce phase noise and systematic errors, ultimately affecting measurement fidelity.In this article, we describe a control architecture of an absolute cold atom gravimeter and the implementation of timing sequences.The design of a radiofrequency synthesizer is also described, crucial for ultra-fast switching and frequency/power control of laser beams in an AQG.
At TCG CREST Kolkata, India, we have started the development of an absolute quantum gravimeter (AQG).In this paper, we will describe the present status and the development of a comprehensive physics package and optical setup highlighting its potential for precise gravity measurements with applications in mining, earthquake detection, and navigation.Our experimental setup has three main building blocks namely, sensor head, optical setup, and electronics.The paper provides insights into the status of our research, shedding light on achieved milestones, challenges, and promising outcomes.Additionally, it outlines the roadmap for future work, emphasizing ongoing developments and innovations.This study contributes to the advancement of measurement techniques for acceleration due to gravity, opening avenues for diverse practical applications and paving the way for further advancements in the field of cold atom gravimetry.
SummaryAbsolute quantum gravimeters (AQG) play a critical role in the precision measurement of gravitational acceleration (g). More and more compact, portable gravimeters are required for the real time applications. For their development, initial step involves preparing and trapping a cold atom cloud, which is the foundation of precision measurements. This work is part of the efforts being made at TCG CREST, India for development of AQG and current status on the magneto-optical trapping of87Rb atoms, and the characterization of the cloud's temperature is discussed.