Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

New Journal of Physics

Axial to transverse energy mixing dynamics in octupole-based magnetostatic antihydrogen traps

A Zhong, J. Fajans, A F Zukor

Published Apr 4, 2018• 11 citations
Publisher

Abstract

Abstract The nature of the trajectories of antihydrogen atoms confined in an octupole minimum-B trap is of great importance for upcoming spectroscopy, cooling, and gravity experiments. Of particular interest is the mixing time between the axial and transverse energies for the antiatoms. Here, using computer simulations, we establish that almost all trajectories are chaotic, and then quantify the characteristic mixing time between the axial and transverse energies. We find that there are two classes of trajectories: for trajectories whose axial energy is higher than about 20% of the total energy, the axial energy substantially mixes within about 10 s, whereas for trajectories whose axial energy is lower than about 10% of the total energy, the axial energy remains nearly constant for 1000 s or longer.

DOI
10.1088/1367-2630/aabb84

Related papers

Collisionless motion of neutral particles in magnetostatic traps

E.L. Surkov, Jook T. M. Walraven, Georgy V. Shlyapnikov

We present an analytical and numerical analysis of collisionless motion of neutral particles in magnetostatic traps. We treat the example of an idealized Ioffe quadrupole trap, emphasizing that the essential features of coupling between the degrees of freedom are of general relevance for static traps. In common situations the coupling between axial and radial motion predominantly occurs in a regular way. The coupling is weak, in particular, when the frequency of axial oscillations ${\mathrm{\ensuremath{\Omega}}}_{\mathit{z}}$ is much smaller than the radial frequency ${\mathrm{\ensuremath{\Omega}}}_{\mathrm{\ensuremath{\rho}}}$ and the particle energy is much lower than the Zeeman energy in the center of the trap. Then, under an adiabatic change of the potential parameters, the quantity ${\mathit{scrE}}_{\mathit{z}}$/${\mathrm{\ensuremath{\Omega}}}_{\mathit{z}}$, where ${\mathit{scrE}}_{\mathit{z}}$ is a characteristic axial energy, is an approximate adiabatic invariant. If ${\mathrm{\ensuremath{\Omega}}}_{\mathit{z}}$ is decreasing and ${\mathrm{\ensuremath{\Omega}}}_{\mathit{p}}$ is constant, then the characteristic radial energy ${\mathit{scrE}}_{\mathrm{\ensuremath{\rho}}}$ will remain constant while ${\mathit{scrE}}_{\mathit{z}}$ decreases proportionally to ${\mathrm{\ensuremath{\Omega}}}_{\mathit{z}}$. This implies one-dimensional adiabatic cooling, which is an interesting option for gravitational studies of light atoms such as hydrogen and antihydrogen.

Physical Review A•Jun 1, 1994•25 citations

Characteristic coupling time between axial and transverse energy modes for antihydrogen in magnetostatic traps

Mike ZHong, J. Fajans

Bulletin of the American Physical Society•Nov 2, 2016•0 citations

Discriminating between antihydrogen and mirror-trapped antiprotons in a minimum-B trap

C. Amole, Gorm Bruun Andresen, M. D. Ashkezari +35 more

Recently, antihydrogen atoms were trapped at CERN in a magnetic minimum (minimum-B) trap formed by superconducting octupole and mirror magnet coils. The trapped antiatoms were detected by rapidly turning off these magnets, thereby eliminating the magnetic minimum and releasing any antiatoms contained in the trap. Once released, these antiatoms quickly hit the trap wall, whereupon the positrons and antiprotons in the antiatoms annihilate. The antiproton annihilations produce easily detected signals; we used these signals to prove that we trapped antihydrogen. However, our technique could be confounded by mirror-trapped antiprotons, which would produce seemingly identical annihilation signals upon hitting the trap wall. In this paper, we discuss possible sources of mirror-trapped antiprotons and show that antihydrogen and antiprotons can be readily distinguished, often with the aid of applied electric fields, by analyzing the annihilation locations and times. We further discuss the general properties of antiproton and antihydrogen trajectories in this magnetic geometry, and reconstruct the antihydrogen energy distribution from the measured annihilation time history.

arXiv:1201.3944•New Journal of Physics•Jan 31, 2012•29 citations

Diagnosing antihydrogen energy distributions using spatio-temporal annihilation patterns

Roya Ahemeh, R Akbari, L O de Araujo Azevedo +54 more

Abstract Precision measurements of the fundamental properties of trapped antihydrogen in the (ALPHA) experiment at CERN require an accurate determination of the antihdyrogen energy distribution. We introduce a new diagnostic technique, termed Spatio-Temporal Annihilation Mapping (STAM), which measures this distribution by exploiting the dynamics of antihydrogen in adiabatically time-varying magnetic fields. By analyzing the spatial and temporal patterns of annihilations recorded during adiabatic release from magnetic confinement and comparing them with detailed simulations, we infer the underlying energy distributions. STAM enables the simultaneous measurement of axial and transverse energy components, achieving a relative precision of approximately 10% over a mean energy range of ∼ 10–100 mK in the ALPHA trap. The technique is applied to both uncooled and laser-cooled antihydrogen populations, with results benchmarked against established laser-based diagnostics. While laser-based methods provide high-resolution measurements of the transverse energy and limited sensitivity to the axial component, an accurate determination of the axial energy remains challenging. In addition to complementing existing techniques, STAM is expected to access energy regimes that are currently inaccessible to laser-based diagnostics due to intrinsic limitations of those methods. These capabilities make STAM broadly applicable to future high-precision spectroscopic and gravitational studies with antihydrogen. Furthermore, STAM provides a novel probe of off-axis magnetic field structures, addressing a critical gap in current magnetometry techniques within the ALPHA experiment.

New Journal of Physics•Aug 1, 2026•0 citations

An Improved Antihydrogen Trap

R. Kalra

The recent demonstration of trapped atomic antihydrogen for 15 to 1000 seconds is a milestone towards precise spectroscopy for tests of CPT invariance. The confinement of a total of 105±21 atoms in a quadrupole magnetic trap was made possible by several improved methods. Improved accumulation techniques give us the largest numbers of constituent particles yet: up to 10 million antiprotons and several billion positrons. A novel cooling protocol leads to 3.5 K antiprotons, the coldest ever observed. Characterizing and controlling the geometry and density of these confined antimatter plasmas allow for consistency in antihydrogen production. Continued use of these methods along with the larger trap depth of a unique second-generation magnet are expected to yield greater numbers of trapped antihydrogen. The new magnet generates both quadrupole and octupole trap geometries, which should make it possible to reduce charged particle loss and will prove useful for laser cooling and spectroscopy. The ultra-low inductances of the magnet have been shown to vastly reduce turn-off times, which will optimize single-atom detection. Finally, improved detector characterization already makes us sensitive to smaller numbers of trapped antihydrogen atoms than before.

Bulletin of the American Physical Society•Jan 20, 2015•0 citations

Antimatter Plasmas in a Multipole Trap for Antihydrogen

Gorm Bruun Andresen, William Alan Bertsche, A.J. Boston +31 more

We have demonstrated storage of plasmas of the charged constituents of the antihydrogen atom, antiprotons and positrons, in a Penning trap surrounded by a minimum-B magnetic trap designed for holding neutral antiatoms. The neutral trap comprises a superconducting octupole and two superconducting, solenoidal mirror coils. We have measured the storage lifetimes of antiproton and positron plasmas in the combined Penning-neutral trap, and compared these to lifetimes without the neutral trap fields. The magnetic well depth was 0.6 T, deep enough to trap ground state antihydrogen atoms of up to about 0.4 K in temperature. We have demonstrated that both particle species can be stored for times long enough to permit antihydrogen production and trapping studies.

Physical Review Letters•Jan 11, 2007•82 citations
Abstract The nature of the trajectories of antihydrogen atoms confined in an octupole minimum-B trap is of great importance for upcoming spectroscopy, cooling, and gravity experiments. Of particular interest is the mixing time between the axial and transverse energies for the antiatoms. Here, using computer simulations, we establish that almost all trajectories are chaotic, and then quantify the characteristic mixing time between the axial and transverse energies. We find that there are two classes of trajectories: for trajectories whose axial energy is higher than about 20% of the total energy, the axial energy substantially mixes within about 10 s, whereas for trajectories whose axial energy is lower than about 10% of the total energy, the axial energy remains nearly constant for 1000 s or longer.
We present an analytical and numerical analysis of collisionless motion of neutral particles in magnetostatic traps. We treat the example of an idealized Ioffe quadrupole trap, emphasizing that the essential features of coupling between the degrees of freedom are of general relevance for static traps. In common situations the coupling between axial and radial motion predominantly occurs in a regular way. The coupling is weak, in particular, when the frequency of axial oscillations ${\mathrm{\ensuremath{\Omega}}}_{\mathit{z}}$ is much smaller than the radial frequency ${\mathrm{\ensuremath{\Omega}}}_{\mathrm{\ensuremath{\rho}}}$ and the particle energy is much lower than the Zeeman energy in the center of the trap. Then, under an adiabatic change of the potential parameters, the quantity scrEz{\mathit{scrE}}_{\mathit{z}}scrEz​/${\mathrm{\ensuremath{\Omega}}}_{\mathit{z}}$, where scrEz{\mathit{scrE}}_{\mathit{z}}scrEz​ is a characteristic axial energy, is an approximate adiabatic invariant. If ${\mathrm{\ensuremath{\Omega}}}_{\mathit{z}}$ is decreasing and ${\mathrm{\ensuremath{\Omega}}}_{\mathit{p}}$ is constant, then the characteristic radial energy ${\mathit{scrE}}_{\mathrm{\ensuremath{\rho}}}$ will remain constant while scrEz{\mathit{scrE}}_{\mathit{z}}scrEz​ decreases proportionally to ${\mathrm{\ensuremath{\Omega}}}_{\mathit{z}}$. This implies one-dimensional adiabatic cooling, which is an interesting option for gravitational studies of light atoms such as hydrogen and antihydrogen.
Recently, antihydrogen atoms were trapped at CERN in a magnetic minimum (minimum-B) trap formed by superconducting octupole and mirror magnet coils. The trapped antiatoms were detected by rapidly turning off these magnets, thereby eliminating the magnetic minimum and releasing any antiatoms contained in the trap. Once released, these antiatoms quickly hit the trap wall, whereupon the positrons and antiprotons in the antiatoms annihilate. The antiproton annihilations produce easily detected signals; we used these signals to prove that we trapped antihydrogen. However, our technique could be confounded by mirror-trapped antiprotons, which would produce seemingly identical annihilation signals upon hitting the trap wall. In this paper, we discuss possible sources of mirror-trapped antiprotons and show that antihydrogen and antiprotons can be readily distinguished, often with the aid of applied electric fields, by analyzing the annihilation locations and times. We further discuss the general properties of antiproton and antihydrogen trajectories in this magnetic geometry, and reconstruct the antihydrogen energy distribution from the measured annihilation time history.
Abstract Precision measurements of the fundamental properties of trapped antihydrogen in the (ALPHA) experiment at CERN require an accurate determination of the antihdyrogen energy distribution. We introduce a new diagnostic technique, termed Spatio-Temporal Annihilation Mapping (STAM), which measures this distribution by exploiting the dynamics of antihydrogen in adiabatically time-varying magnetic fields. By analyzing the spatial and temporal patterns of annihilations recorded during adiabatic release from magnetic confinement and comparing them with detailed simulations, we infer the underlying energy distributions. STAM enables the simultaneous measurement of axial and transverse energy components, achieving a relative precision of approximately 10% over a mean energy range of ∼ 10–100 mK in the ALPHA trap. The technique is applied to both uncooled and laser-cooled antihydrogen populations, with results benchmarked against established laser-based diagnostics. While laser-based methods provide high-resolution measurements of the transverse energy and limited sensitivity to the axial component, an accurate determination of the axial energy remains challenging. In addition to complementing existing techniques, STAM is expected to access energy regimes that are currently inaccessible to laser-based diagnostics due to intrinsic limitations of those methods. These capabilities make STAM broadly applicable to future high-precision spectroscopic and gravitational studies with antihydrogen. Furthermore, STAM provides a novel probe of off-axis magnetic field structures, addressing a critical gap in current magnetometry techniques within the ALPHA experiment.
The recent demonstration of trapped atomic antihydrogen for 15 to 1000 seconds is a milestone towards precise spectroscopy for tests of CPT invariance. The confinement of a total of 105±21 atoms in a quadrupole magnetic trap was made possible by several improved methods. Improved accumulation techniques give us the largest numbers of constituent particles yet: up to 10 million antiprotons and several billion positrons. A novel cooling protocol leads to 3.5 K antiprotons, the coldest ever observed. Characterizing and controlling the geometry and density of these confined antimatter plasmas allow for consistency in antihydrogen production. Continued use of these methods along with the larger trap depth of a unique second-generation magnet are expected to yield greater numbers of trapped antihydrogen. The new magnet generates both quadrupole and octupole trap geometries, which should make it possible to reduce charged particle loss and will prove useful for laser cooling and spectroscopy. The ultra-low inductances of the magnet have been shown to vastly reduce turn-off times, which will optimize single-atom detection. Finally, improved detector characterization already makes us sensitive to smaller numbers of trapped antihydrogen atoms than before.
We have demonstrated storage of plasmas of the charged constituents of the antihydrogen atom, antiprotons and positrons, in a Penning trap surrounded by a minimum-B magnetic trap designed for holding neutral antiatoms. The neutral trap comprises a superconducting octupole and two superconducting, solenoidal mirror coils. We have measured the storage lifetimes of antiproton and positron plasmas in the combined Penning-neutral trap, and compared these to lifetimes without the neutral trap fields. The magnetic well depth was 0.6 T, deep enough to trap ground state antihydrogen atoms of up to about 0.4 K in temperature. We have demonstrated that both particle species can be stored for times long enough to permit antihydrogen production and trapping studies.