IEEE International Superconductive Electronics Conference (ISEC)

Towards a He-Free Source of Arbitrary Quantum Voltage Signals

Paolo Durandetto, E. Monticone, Bruno Trinchera, A. Sosso

Published Jun 1, 2017• 0 citations
Publisher

Abstract

The Josephson effect is worldwide exploited as the basis for constant reference voltages in National Metrological Institutes (NMIs) and in industry calibration laboratories. Lately, voltage metrology research has been mainly directed towards the application of Josephson effect for the synthesis of very accurate ac and arbitrary voltage signals: pulse-driven Josephson arrays represent the most promising way for linking ac voltage calibrations to a quantum phenomenon. Furthermore, an easy and secure cooling system based on cryocoolers is desirable in order to allow the spread of Josephson standards outside NMIs. A Gifford-McMahon cryocooler is currently in use at INRiM for the operation of ac-Josephson Voltage Standards (JVSs). We employed pulse-driven JVSs for synthesizing sine waves with frequency in the kHz range and amplitudes in the mV range, with distortion around 80 dBc. In this report we present a detailed description of this technique and of the refrigeration system employed.

DOI
10.1109/isec.2017.8314217

Related papers

Josephson-based quantum voltage standards – an ongoing success story

Ralf Behr, Stephan Bauer, Marco Kraus +2 more

The past few decades have witnessed great progress being made from the first voltage standards based on arrays of Josephson junctions. Continuous improvements in the fabrication process have increased the quality and “user-friendliness” of these superconducting circuits. Combined with the improvements in measuring electronics, the range of applications of Josephson-based measurements with unmatched precision has extended from DC into AC voltage metrology for signal frequencies up to 500 kHz. In this poster we will present several Josephson-based measurement systems developed for metrology applications. Two versions of quantum AC standards will be used as Josephson references: Programmable Josephson Voltage Standards (PJVS), which are based on serial arrays with up to 300,000 Josephson junctions, and pulse-driven arrays with more than 50,000 junctions, typically referred to as Josephson Arbitrary Waveform Synthesizers (JAWS). PJVS can reach amplitudes of up to 80 V, while pulse-driven arrays can reach up to 1 V or even 4 V. The advantage of pulse-driven Josephson voltage standards is that they are ideally suited as quantum-based voltage synthesizers for arbitrary waveforms or sine waves with high spectral purity. Therefore, they can be used directly to characterize or calibrate ADCs. In addition, JAWS are particularly useful in Josephson impedance bridges, which perform automated impedance calibrations at the 10-9 uncertainty level over a wide frequency range from 50 Hz to 80 kHz in a single bridge. We will further show how PJVS are used in commercial quantum voltmeters for DC and AC voltages and are typically used as quantum voltage references in measurement systems. Using differential sampling based on PJVS, uncertainties at the level of a few parts in 108 for frequencies up to the kHz range can be achieved. Such quantum-based AC voltage calibrations are at least 30 times faster than conventional AC-DC transfer and offer even better uncertainties. This idea has been quickly adopted by many National Metrology Institutes to establish such systems for AC voltage calibrations. As an example, the BIPM will now start worldwide onsite comparisons to ensure the uniformity of the new method which we introduced in 2006. But developments continue. Recently, a sub-sampling technique was used to extend the frequency range of the AC quantum voltmeter to up to 100 kHz with uncertainties below 5 parts in 106. In addition, a novel method, also for differential sampling, enables the measurement of arbitrary waveforms and the calibration of specific tones. Our poster will provide an overview of these Josephson-based metrological applications and present the latest developments from this fast-developing area.

•Jan 1, 2025•0 citations

Pulse-Driven Josephson Junction Arrays for High-Precision AC-Voltage Synthesis of Unipolar and Bipolar Waveforms

M. Schubert, G. Wende, T. May +5 more

The paper is about development of the lumped Josephson junction arrays (JJAs) for the generation of accurate quantum-based ac voltages. By using semiconductor pattern generators, it was possible to synthesize unipolar and bipolar waveforms with amplitudes of almost 10 mV and frequencies of up to 122 kHz. Higher harmonics and other unwanted noise signals were suppressed by -90 dBc. Because of the unique layout of our JJA, it was possible to connect the circuit directly to the ground, thereby eliminating common-mode signals

IEEE Transactions on Instrumentation and Measurement•Mar 16, 2007•3 citations

A pulse-driven Josephson arbitrary waveform synthesis system as a quantum AC voltage standard in KRISS

Yonuk Chong, Woon Young Song, Jung-Suk Choi +4 more

We report our progress in the Josephson arbitrary waveform synthesis system in KRISS. The system is based on the pulse-driven Josephson junction array, and currently we routinely produce arbitrary waveforms up to 100 mVrms amplitude with distortions smaller than 100 dBc. Precision waveform synthesis results are presented. Our future works will include AC-DC thermal transfer measurement and quantum noise source for Johnson noise thermometry.

Conference on Precision Electromagnetic Measurements•Jun 1, 2010•3 citations

Utilization of a cryo-prober system for operation of a pulse-driven josephson junction array

Michitaka Maruyama, Chiharu Urano, Nobu‐Hisa Kaneko +9 more

We demonstrated the operation of pulse-driven Josephson junction arrays (JJAs) for AC voltage standard using a wideband cryo-prober system with a 4-K Gifford-MacMahon (GM) cooler. This unique system was originally developed for high-speed network switch applications of rapid-single-flux-quantum (RSFQ) circuits and enables wideband data transmission at bit rates of higher than 10 Gbps between room-temperature and cryogenic environments. JJA chips were fabricated using NbN-based superconductor-normal metal-superconductor (SNS) junctions. A 5-mm chip was mounted on a 16-mm chip carrier using flip-chip bonding technology for probe contact. To obtain bipolar output voltages, we tried two types of testing based on the AC coupling technique proposed by the National Institute of Standards and Technology (NIST). A pulse pattern generator (PPG) with a large memory of 134 Mbit was used for covering a wide frequency range of output signals. As a result, we succeeded in bipolar operation of the JJA, generating waveforms at frequencies from 60 Hz to several tens of kilo hertz. The maximum rms voltage obtained for a single array was 12.7 mV. The observed spurious level was lower than -93 dBc at 16 kHz.

Journal of Physics Conference Series•Jun 1, 2010•2 citations

A Josephson Arbitrary Waveform Synthesizer with Ultra-Short Cables Optimized for Operations of up to 2 MHz

Rinis Ferizaj, Stephan Bauer, Ralf Behr +1 more

Quantum AC voltage standards are important for AC voltage and impedance metrology. Current experiments show that pulse-driven Josephson Arbitrary Waveform Synthesizers (JAWS) are used in metrological applications with low uncertainties up to about 500 kHz. Higher frequencies are limited by dispersion, attenuation, and impedance mismatch in long cryostat wiring, effects that scale approximately with the square of the cable length. To circumvent these limitations, we set up a JAWS setup in a special cryocooler, significantly reducing cable lengths.

Conference on Precision Electromagnetic Measurements•Sep 1, 2026•0 citations

Applications: Metrology

John C. Gallop, Ling Hao, Alain Rüfenacht

Metrology is the science of precision measurement of physical quantities and has developed a close relationship with superconductivity and superconducting materials, beginning with the discoveries of magnetic flux quantization and the Josephson effects in 1961 and 1962. Programmable Josephson voltage standard systems were first proposed and developed at NIST and are nowadays fully demonstrated in numerous metrology measurements and operated in liquid-cryogen-free refrigerators. A Josephson array device with growing applications to ac voltage metrology has emerged in recent years: the pulse-driven Josephson arbitrary waveform synthesizer. The use of superconductors in solenoids allows current densities to be much higher than for conventional conductors due to zero Joule heating. The Josephson effect has been applied to temperature measurement through the detection of Johnson noise using various superconducting junction-based technologies. The most recent application of Josephson technologies to temperature metrology involves the use of quantum-based reference noise-voltage waveforms synthesized by arrays of Josephson junctions.

CRC Press eBooks•May 17, 2022•0 citations
The Josephson effect is worldwide exploited as the basis for constant reference voltages in National Metrological Institutes (NMIs) and in industry calibration laboratories. Lately, voltage metrology research has been mainly directed towards the application of Josephson effect for the synthesis of very accurate ac and arbitrary voltage signals: pulse-driven Josephson arrays represent the most promising way for linking ac voltage calibrations to a quantum phenomenon. Furthermore, an easy and secure cooling system based on cryocoolers is desirable in order to allow the spread of Josephson standards outside NMIs. A Gifford-McMahon cryocooler is currently in use at INRiM for the operation of ac-Josephson Voltage Standards (JVSs). We employed pulse-driven JVSs for synthesizing sine waves with frequency in the kHz range and amplitudes in the mV range, with distortion around 80 dBc. In this report we present a detailed description of this technique and of the refrigeration system employed.
The past few decades have witnessed great progress being made from the first voltage standards based on arrays of Josephson junctions. Continuous improvements in the fabrication process have increased the quality and “user-friendliness” of these superconducting circuits. Combined with the improvements in measuring electronics, the range of applications of Josephson-based measurements with unmatched precision has extended from DC into AC voltage metrology for signal frequencies up to 500 kHz. In this poster we will present several Josephson-based measurement systems developed for metrology applications. Two versions of quantum AC standards will be used as Josephson references: Programmable Josephson Voltage Standards (PJVS), which are based on serial arrays with up to 300,000 Josephson junctions, and pulse-driven arrays with more than 50,000 junctions, typically referred to as Josephson Arbitrary Waveform Synthesizers (JAWS). PJVS can reach amplitudes of up to 80 V, while pulse-driven arrays can reach up to 1 V or even 4 V. The advantage of pulse-driven Josephson voltage standards is that they are ideally suited as quantum-based voltage synthesizers for arbitrary waveforms or sine waves with high spectral purity. Therefore, they can be used directly to characterize or calibrate ADCs. In addition, JAWS are particularly useful in Josephson impedance bridges, which perform automated impedance calibrations at the 10-9 uncertainty level over a wide frequency range from 50 Hz to 80 kHz in a single bridge. We will further show how PJVS are used in commercial quantum voltmeters for DC and AC voltages and are typically used as quantum voltage references in measurement systems. Using differential sampling based on PJVS, uncertainties at the level of a few parts in 108 for frequencies up to the kHz range can be achieved. Such quantum-based AC voltage calibrations are at least 30 times faster than conventional AC-DC transfer and offer even better uncertainties. This idea has been quickly adopted by many National Metrology Institutes to establish such systems for AC voltage calibrations. As an example, the BIPM will now start worldwide onsite comparisons to ensure the uniformity of the new method which we introduced in 2006. But developments continue. Recently, a sub-sampling technique was used to extend the frequency range of the AC quantum voltmeter to up to 100 kHz with uncertainties below 5 parts in 106. In addition, a novel method, also for differential sampling, enables the measurement of arbitrary waveforms and the calibration of specific tones. Our poster will provide an overview of these Josephson-based metrological applications and present the latest developments from this fast-developing area.
The paper is about development of the lumped Josephson junction arrays (JJAs) for the generation of accurate quantum-based ac voltages. By using semiconductor pattern generators, it was possible to synthesize unipolar and bipolar waveforms with amplitudes of almost 10 mV and frequencies of up to 122 kHz. Higher harmonics and other unwanted noise signals were suppressed by -90 dBc. Because of the unique layout of our JJA, it was possible to connect the circuit directly to the ground, thereby eliminating common-mode signals
We demonstrated the operation of pulse-driven Josephson junction arrays (JJAs) for AC voltage standard using a wideband cryo-prober system with a 4-K Gifford-MacMahon (GM) cooler. This unique system was originally developed for high-speed network switch applications of rapid-single-flux-quantum (RSFQ) circuits and enables wideband data transmission at bit rates of higher than 10 Gbps between room-temperature and cryogenic environments. JJA chips were fabricated using NbN-based superconductor-normal metal-superconductor (SNS) junctions. A 5-mm chip was mounted on a 16-mm chip carrier using flip-chip bonding technology for probe contact. To obtain bipolar output voltages, we tried two types of testing based on the AC coupling technique proposed by the National Institute of Standards and Technology (NIST). A pulse pattern generator (PPG) with a large memory of 134 Mbit was used for covering a wide frequency range of output signals. As a result, we succeeded in bipolar operation of the JJA, generating waveforms at frequencies from 60 Hz to several tens of kilo hertz. The maximum rms voltage obtained for a single array was 12.7 mV. The observed spurious level was lower than -93 dBc at 16 kHz.
Quantum AC voltage standards are important for AC voltage and impedance metrology. Current experiments show that pulse-driven Josephson Arbitrary Waveform Synthesizers (JAWS) are used in metrological applications with low uncertainties up to about 500 kHz. Higher frequencies are limited by dispersion, attenuation, and impedance mismatch in long cryostat wiring, effects that scale approximately with the square of the cable length. To circumvent these limitations, we set up a JAWS setup in a special cryocooler, significantly reducing cable lengths.
Metrology is the science of precision measurement of physical quantities and has developed a close relationship with superconductivity and superconducting materials, beginning with the discoveries of magnetic flux quantization and the Josephson effects in 1961 and 1962. Programmable Josephson voltage standard systems were first proposed and developed at NIST and are nowadays fully demonstrated in numerous metrology measurements and operated in liquid-cryogen-free refrigerators. A Josephson array device with growing applications to ac voltage metrology has emerged in recent years: the pulse-driven Josephson arbitrary waveform synthesizer. The use of superconductors in solenoids allows current densities to be much higher than for conventional conductors due to zero Joule heating. The Josephson effect has been applied to temperature measurement through the detection of Johnson noise using various superconducting junction-based technologies. The most recent application of Josephson technologies to temperature metrology involves the use of quantum-based reference noise-voltage waveforms synthesized by arrays of Josephson junctions.