Review of Scientific Instruments

Note: An atomic self-sustaining magnetic gradiometer with a 1/τ uncertainty property based on Larmor precession

B. L. Fan, Shiguang Wang, Chi Xu, L. J. Wang

Published Feb 1, 2018• 4 citations
Publisher

Abstract

We demonstrate an atomic magnetic gradiometer based on self-sustaining Larmor precession. By coherent optical pumping, we measure the phase of the Larmor precession directly and observe that the gradiometer shows a 1/τ improvement in magnetic field gradient uncertainty over time τ. Since the measurement gives frequency signals, the gradiometer can be easily implemented by mixing and filtering the different frequency signals from two adjacent magnetometers. A gradient sensitivity of 186 fT/Hz/cm−1) is realized, which is close to the shot-noise limit. In a noisy environment, the gradiometer can still maintain its 1/τ behavior by suppressing 90% of the common-mode noise. This method should be widely applicable to the measurement of magnetic field gradients owing to its simplicity and outstanding performance.

DOI
10.1063/1.5003872

Related papers

An atomic magnetic gradiometer with 1/τ uncertainty property based on the self-sustaining method

Qin Zhao, Boling Fan, Shiguang Wang +1 more

The magnetic field is one of the most important physical observables with about all electromagnetic information. Larmor precession atomic magnetometers based on optical pumping experienced considerable attention recently. However, the sensitivity of this kind of atomic magnetometers is limited by their spin coherence time and the systematic noise. Here, we propose a self-sustaining atomic magnetic gradiometer that shows a superior 1/τ behavior in the magnetic field uncertainty measurement over time. The gradiometer is implemented by mixing and filtering the different frequency signals from two adjacent spin self-sustaining magnetometers with a baseline equal to 1 cm. The common-mode noise is suppressed and a gradient sensitivity of 200 fT/(√Hz=cm) is realized, being close to the shot noise limit.

International Conference on Photonics and Optical Engineering•Jan 24, 2019•0 citations

A self-sustaining atomic magnetometer with τ−1 averaging property

Chi Xu, Shiguang Wang, Y. Y. Feng +2 more

Quantum measurement using coherent superposition of intrinsic atomic states has the advantage of being absolute measurement and can form metrological standards. One example is the absolute measurement of magnetic field by monitoring the Larmor precession of atomic spins whilst another being the Ramsey type atomic clock. Yet, in almost all coherent quantum measurement, the precision is limited by the coherence time beyond which, the uncertainty decreases only as τ(-1/2). Here we show that by non-destructively measuring the phase of the Larmor precession and regenerating the coherence via optical pumping, the self-sustaining Larmor precession signal can persist indefinitely. Consequently, the precision of the magnetometer increases with time following a much faster τ(-1) rule. A mean sensitivity of 240 from 1 Hz to 10 Hz is realized, being close to the shot noise level. This method of coherence regeneration may also find important applications in improving the performance of atomic clocks.

Scientific Reports•Jun 30, 2016•16 citations

Investigation and improvement of the spin self-sustaining magnetometer

Q. Zhao, B. L. Fan, Shiguang Wang +1 more

The spin self-sustaining atomic magnetometer has the advantage of 1/τ measurement and great development potential in many applications. In this paper, we investigated the main elements that affect the stability and accuracy of the self-sustaining magnetometer and proposed the methods to improve its performance based on the measurement results. The correlation coefficient between fluctuations of the magnetic field generated by coils and the spin Larmor precession frequency is 0.97, which mainly dominates the stability in a short term. The accuracy of the magnetometer is affected by the power and frequency of the pump light. The Larmor precession frequency coefficient related to the pump light power is 26 mHz/mW, and the effect on the Larmor precession frequency is minimized when the pump light frequency is red detuned by 200 MHz from the 85Rb transition D1 line F = 3 to F′ = 3. The 1/τ measurement time after these corrections can be extended to 10 s, and the sensitivity achieved is 149 fT/Hz, which is close to the quantum projection noise limit of the system.

AIP Advances•Sep 1, 2020•0 citations

A microfabricated optically-pumped magnetic gradiometer

D. Sheng, Abigail R. Perry, Sean Krzyzewski +3 more

We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/[Formula: see text] at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensation coils wrapped around the sensor, we also measure the sensor sensitivity at several external bias field strengths up to 150 mG. This device is useful for applications that require both sensitive gradient field information and high common-mode noise cancellation.

arXiv:1701.03236•Applied Physics Letters•Jan 16, 2017•181 citations

Single-shot Stern-Gerlach magnetic gradiometer with an expanding cloud of cold cesium atoms

Katja Gosar, Tina Arh, Tadej Mežnaršič +8 more

We combine the Ramsey interferometry protocol, the Stern-Gerlach detection scheme, and the use of elongated geometry of a cloud of fully polarized cold cesium atoms to measure the selected component of the magnetic-field gradient along the atomic cloud in a single shot. In contrast to the standard method where the precession of two spatially separated atomic clouds is simultaneously measured to extract their phase difference, which is proportional to the magnetic-field gradient, we here demonstrate a gradiometer using a single image of an expanding atomic cloud with the phase difference imprinted along the cloud. Using resonant radio-frequency pulses and Stern-Gerlach imaging, we first demonstrate nutation and Larmor precession of atomic magnetization in an applied magnetic field. Next, we let the cold atom cloud expand in one dimension and apply the protocol for measuring the magnetic-field gradient. The resolution of our single-shot gradiometer is not limited by thermal motion of atoms and has an estimated absolute accuracy below $\ifmmode\pm\else\textpm\fi{}0.2$ mG/cm ($\ifmmode\pm\else\textpm\fi{}20$ nT/cm).

arXiv:2011.09779•Physical Review A•Feb 19, 2021•6 citations

Rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation

Pei-Xian Miao, Shiyu Yang, Wang Jian-Xiang +4 more

We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.

Acta Physica Sinica•Jan 1, 2017•12 citations
We demonstrate an atomic magnetic gradiometer based on self-sustaining Larmor precession. By coherent optical pumping, we measure the phase of the Larmor precession directly and observe that the gradiometer shows a 1/τ improvement in magnetic field gradient uncertainty over time τ. Since the measurement gives frequency signals, the gradiometer can be easily implemented by mixing and filtering the different frequency signals from two adjacent magnetometers. A gradient sensitivity of 186 fT/Hz/cm−1) is realized, which is close to the shot-noise limit. In a noisy environment, the gradiometer can still maintain its 1/τ behavior by suppressing 90% of the common-mode noise. This method should be widely applicable to the measurement of magnetic field gradients owing to its simplicity and outstanding performance.
The magnetic field is one of the most important physical observables with about all electromagnetic information. Larmor precession atomic magnetometers based on optical pumping experienced considerable attention recently. However, the sensitivity of this kind of atomic magnetometers is limited by their spin coherence time and the systematic noise. Here, we propose a self-sustaining atomic magnetic gradiometer that shows a superior 1/τ behavior in the magnetic field uncertainty measurement over time. The gradiometer is implemented by mixing and filtering the different frequency signals from two adjacent spin self-sustaining magnetometers with a baseline equal to 1 cm. The common-mode noise is suppressed and a gradient sensitivity of 200 fT/(√Hz=cm) is realized, being close to the shot noise limit.
Quantum measurement using coherent superposition of intrinsic atomic states has the advantage of being absolute measurement and can form metrological standards. One example is the absolute measurement of magnetic field by monitoring the Larmor precession of atomic spins whilst another being the Ramsey type atomic clock. Yet, in almost all coherent quantum measurement, the precision is limited by the coherence time beyond which, the uncertainty decreases only as τ(-1/2). Here we show that by non-destructively measuring the phase of the Larmor precession and regenerating the coherence via optical pumping, the self-sustaining Larmor precession signal can persist indefinitely. Consequently, the precision of the magnetometer increases with time following a much faster τ(-1) rule. A mean sensitivity of 240 from 1 Hz to 10 Hz is realized, being close to the shot noise level. This method of coherence regeneration may also find important applications in improving the performance of atomic clocks.
The spin self-sustaining atomic magnetometer has the advantage of 1/τ measurement and great development potential in many applications. In this paper, we investigated the main elements that affect the stability and accuracy of the self-sustaining magnetometer and proposed the methods to improve its performance based on the measurement results. The correlation coefficient between fluctuations of the magnetic field generated by coils and the spin Larmor precession frequency is 0.97, which mainly dominates the stability in a short term. The accuracy of the magnetometer is affected by the power and frequency of the pump light. The Larmor precession frequency coefficient related to the pump light power is 26 mHz/mW, and the effect on the Larmor precession frequency is minimized when the pump light frequency is red detuned by 200 MHz from the 85Rb transition D1 line F = 3 to F′ = 3. The 1/τ measurement time after these corrections can be extended to 10 s, and the sensitivity achieved is 149 fT/Hz, which is close to the quantum projection noise limit of the system.
We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/[Formula: see text] at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensation coils wrapped around the sensor, we also measure the sensor sensitivity at several external bias field strengths up to 150 mG. This device is useful for applications that require both sensitive gradient field information and high common-mode noise cancellation.
We combine the Ramsey interferometry protocol, the Stern-Gerlach detection scheme, and the use of elongated geometry of a cloud of fully polarized cold cesium atoms to measure the selected component of the magnetic-field gradient along the atomic cloud in a single shot. In contrast to the standard method where the precession of two spatially separated atomic clouds is simultaneously measured to extract their phase difference, which is proportional to the magnetic-field gradient, we here demonstrate a gradiometer using a single image of an expanding atomic cloud with the phase difference imprinted along the cloud. Using resonant radio-frequency pulses and Stern-Gerlach imaging, we first demonstrate nutation and Larmor precession of atomic magnetization in an applied magnetic field. Next, we let the cold atom cloud expand in one dimension and apply the protocol for measuring the magnetic-field gradient. The resolution of our single-shot gradiometer is not limited by thermal motion of atoms and has an estimated absolute accuracy below $\ifmmode\pm\else\textpm\fi{}0.2$ mG/cm ($\ifmmode\pm\else\textpm\fi{}20$ nT/cm).
We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.