Physical Review A

Optical-plus-microwave pumping in a magnetically insensitive state of cold atoms

Yaning Wang, Yanling Meng, Jinyin Wan, Mingyuan Yu, Xin Wang, Ling Xiao, Hua-Dong Cheng, Liang Liu

Published Feb 26, 2018• 14 citations
Publisher

Abstract

An optical-plus-microwave pumping method is implemented and optimized to pump cold atoms to a magnetically insensitive state in an integrating sphere. This method consists of several optical and microwave pulses with a proper time sequence. The relative population of cold atoms in the Zeeman sublevel $|F=1,{m}_{F}=0\ensuremath{\rangle}$ is tested by measuring the Rabi oscillations and Ramsey fringes with different numbers of optical and microwave pumping pulses, demonstrating that nearly 83% of the cold atoms can be prepared in the clock state. The number of cold atoms in the target state is up to 2.5 times more than that of the optical pumping alone. Thus, the limitation on the stability of an integrating sphere cold-atom clock from atomic noise is estimated to be from $4.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ to $3.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$. This method is also suitable for other precision measurements with cold atoms.

DOI
10.1103/physreva.97.023421

Related papers

An effective pumping method for increasing atomic utilization in a compact cold atom clock*

Xinchuan Ouyang, Bowen Yang, Jianliao Deng +5 more

We propose a simple pumping method to increase the effective population of cold atoms in the clock state and investigate the factors which affect the pumping efficiency in cold atom systems. We report the theory and demonstrate the corresponding experiment in an 87Rb integrating sphere cold atom clock. The experimental results show that the population of cold atoms in the Zeeman sublevel |F = 2, mF = 0〉 is approximately 1.62 times that of the result using optical pumping alone. This method can also be applied to increase the effective population in any one of the target Zeeman sublevels in other cold atom systems.

Chinese Physics B•Apr 29, 2021•2 citations

Optimizing population accumulation in a designated single Zeeman state using microwave spectroscopy

Jia-You Liou, Chien‐Ting Wu, Hsuan-Jui Su +1 more

We present an all-optical method for the highly efficient preparation of cold atoms in a specific Zeeman state, such as the magnetically insensitive clock state ( m F = 0) or a particular state suitable for quantum information processing and storage. This technique employs a single microwave spectrum, enabling precise determination of the population distribution, microwave polarization ratio, and microwave Rabi frequency individually. By analyzing the microwave spectrum, we can track the population distribution while systematically varying the power or period of the optical pumping field(s). In steady-state conditions, our simplified model, which incorporates resonant and off-resonant transitions, reveals an upper limit to the population purity. Through the optimization of the intensity and polarization of the optical pumping field, we have achieved exceptional population purities of up to 96(2)% or 98(1)% for the desired quantum state. These remarkable results indicate a significant advancement in state preparation accuracy. Our all-optical method introduces an approach to achieving high-purity atomic states while employing novel microwave spectroscopy to accurately detect all unknown parameters, offering valuable insights and potential applications in precision measurement and quantum computation research.

arXiv:2302.12660•Optics Continuum•Aug 28, 2023•3 citations

A compact cold-atom double-resonance clock

Alan Bregazzi, Etienne Batori, Ben Lewis +4 more

We present a demonstration of a cold-atom optical-microwave double resonance (DR) Ramsey clock utilising an additively manufactured loop-gap-resonator cavity and grating magneto-optical trap (GMOT). The use of additive manufacturing allows for complex cavity structures, more difficult to produce with traditional machining techniques, while the GMOT architecture significantly simplifies the optical system required to trap and cool the atomic sample. In the current demonstration a single laser is used to trap < 3 × 106 87Rb atoms, cool them to below 10 µK, optically pump and read-out state populations of the atoms after microwave interrogation. A Ramsey-type interrogation scheme is employed with an empirically evaluated optimum free evolution time of 10 ms, limited by the loss of signal due to atoms falling out of the read-out beam. We demonstrate a short-term stability of < 2×10−11τ−1/2, in reasonable agreement with the predicted short-term stability based on the signal to noise ratio of the measured Ramsey fringes. Excellent field homogeneity of the cavity microwave field is demonstrated though Rabi oscillations, while almost complete optical pumping and good field orientation is evidenced by Zeeman spectroscopy of the ground-state hyperfine energy levels. This work is a novel approach towards more compact and portable cold-atom microwave clocks with significant potential for further miniaturization of the system.

Optical and Quantum Sensing and Precision Metrology II•Mar 8, 2023•0 citations

Integrating sphere cold atom clock with cylindrical microwave cavity

Xucheng Wang, Hua-Dong Cheng, Ben-Chang Zheng +4 more

The integrating sphere is used to generate the diffuse light for cooling atoms. The microwave field is produced in a cylindrical cavity on a TE011 mode. We have realized the microwave interrogation with the pulsed optically pumped (POP) scheme. The Ramsey fringe is demonstrated and some factors to affect the signal to noise ratio (SNR) and the contrast of the fringe are discussed. Optimization of the experimental parameters is still in progress.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2011•1 citation

Rabi pulling effect in a compact cold-atom clock

Haojie Zhao, Bowen Yang, Yuhan Yan +7 more

We theoretically and experimentally investigate the Rabi pulling effect in an integrating sphere cold-atom clock (ISCAC). Rabi pulling in an ISCAC is caused by magnetic-sublevel transitions between hyperfine states and is related to the amplitude of the microwave pulse, the bias magnetic field, and the density distribution of cold atoms. Theoretical analysis shows the Rabi closed-loop scheme reduces microwave power fluctuation sensitivity by two orders compared to the Ramsey scheme. Experimentally, the Rabi closed-loop scheme achieves a long-term frequency stability of $1.9\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ at an averaging time of $200\phantom{\rule{0.16em}{0ex}}000$ s.

Physical Review A•Nov 24, 2025•0 citations

Atomic Clock Using Microwave Pulse-Coherent Techniques

Maurice Arditi, T. R. Carver

In order to eliminate the light shifts and to increase the stability of gas-cell atomic clocks using optical pumping of the alkali atoms, the detection of a microwave pulse-induced coherent emission is used as the correction signal to lock a crystal oscillator to the atomic transition. Also, the line width of the O-O hyperfine transition is artificially narrowed by subjecting the atoms in the cell to two phase-coherent microwave pulses. In this case the resonance line has a width characteristic of the pulse-repetition frequency which can be made several times smaller than the natural line width in the cell. Proper timing of the sequence of microwave pulses and light pulses for optical pumping is necessary to conserve phase coherence and to obtain a well-defined Ramsey pattern. Results of the tests on a laboratory model using Rubidium-87 atoms show the elimination of the light shifts and an improvement of the short-term stability of the crystal oscillator by one order of magnitude.

IEEE Transactions on Instrumentation and Measurement•Jun 1, 1964•43 citations
An optical-plus-microwave pumping method is implemented and optimized to pump cold atoms to a magnetically insensitive state in an integrating sphere. This method consists of several optical and microwave pulses with a proper time sequence. The relative population of cold atoms in the Zeeman sublevel ∣F=1,mF=0\ensuremath⟩|F=1,{m}_{F}=0\ensuremath{\rangle}∣F=1,mF​=0\ensuremath⟩ is tested by measuring the Rabi oscillations and Ramsey fringes with different numbers of optical and microwave pumping pulses, demonstrating that nearly 83% of the cold atoms can be prepared in the clock state. The number of cold atoms in the target state is up to 2.5 times more than that of the optical pumping alone. Thus, the limitation on the stability of an integrating sphere cold-atom clock from atomic noise is estimated to be from 4.6\ifmmode×\else\texttimes\fi10\ensuremath−13\ensuremathτ\ensuremath−1/24.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}4.6\ifmmode×\else\texttimes\fi10\ensuremath−13\ensuremathτ\ensuremath−1/2 to 3.0\ifmmode×\else\texttimes\fi10\ensuremath−13\ensuremathτ\ensuremath−1/23.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}3.0\ifmmode×\else\texttimes\fi10\ensuremath−13\ensuremathτ\ensuremath−1/2. This method is also suitable for other precision measurements with cold atoms.
We propose a simple pumping method to increase the effective population of cold atoms in the clock state and investigate the factors which affect the pumping efficiency in cold atom systems. We report the theory and demonstrate the corresponding experiment in an 87Rb integrating sphere cold atom clock. The experimental results show that the population of cold atoms in the Zeeman sublevel |F = 2, mF = 0〉 is approximately 1.62 times that of the result using optical pumping alone. This method can also be applied to increase the effective population in any one of the target Zeeman sublevels in other cold atom systems.
We present an all-optical method for the highly efficient preparation of cold atoms in a specific Zeeman state, such as the magnetically insensitive clock state ( m F = 0) or a particular state suitable for quantum information processing and storage. This technique employs a single microwave spectrum, enabling precise determination of the population distribution, microwave polarization ratio, and microwave Rabi frequency individually. By analyzing the microwave spectrum, we can track the population distribution while systematically varying the power or period of the optical pumping field(s). In steady-state conditions, our simplified model, which incorporates resonant and off-resonant transitions, reveals an upper limit to the population purity. Through the optimization of the intensity and polarization of the optical pumping field, we have achieved exceptional population purities of up to 96(2)% or 98(1)% for the desired quantum state. These remarkable results indicate a significant advancement in state preparation accuracy. Our all-optical method introduces an approach to achieving high-purity atomic states while employing novel microwave spectroscopy to accurately detect all unknown parameters, offering valuable insights and potential applications in precision measurement and quantum computation research.
We present a demonstration of a cold-atom optical-microwave double resonance (DR) Ramsey clock utilising an additively manufactured loop-gap-resonator cavity and grating magneto-optical trap (GMOT). The use of additive manufacturing allows for complex cavity structures, more difficult to produce with traditional machining techniques, while the GMOT architecture significantly simplifies the optical system required to trap and cool the atomic sample. In the current demonstration a single laser is used to trap < 3 × 106 87Rb atoms, cool them to below 10 µK, optically pump and read-out state populations of the atoms after microwave interrogation. A Ramsey-type interrogation scheme is employed with an empirically evaluated optimum free evolution time of 10 ms, limited by the loss of signal due to atoms falling out of the read-out beam. We demonstrate a short-term stability of < 2×10−11τ−1/2, in reasonable agreement with the predicted short-term stability based on the signal to noise ratio of the measured Ramsey fringes. Excellent field homogeneity of the cavity microwave field is demonstrated though Rabi oscillations, while almost complete optical pumping and good field orientation is evidenced by Zeeman spectroscopy of the ground-state hyperfine energy levels. This work is a novel approach towards more compact and portable cold-atom microwave clocks with significant potential for further miniaturization of the system.
We theoretically and experimentally investigate the Rabi pulling effect in an integrating sphere cold-atom clock (ISCAC). Rabi pulling in an ISCAC is caused by magnetic-sublevel transitions between hyperfine states and is related to the amplitude of the microwave pulse, the bias magnetic field, and the density distribution of cold atoms. Theoretical analysis shows the Rabi closed-loop scheme reduces microwave power fluctuation sensitivity by two orders compared to the Ramsey scheme. Experimentally, the Rabi closed-loop scheme achieves a long-term frequency stability of $1.9\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ at an averaging time of 200000200\phantom{\rule{0.16em}{0ex}}000200000 s.
In order to eliminate the light shifts and to increase the stability of gas-cell atomic clocks using optical pumping of the alkali atoms, the detection of a microwave pulse-induced coherent emission is used as the correction signal to lock a crystal oscillator to the atomic transition. Also, the line width of the O-O hyperfine transition is artificially narrowed by subjecting the atoms in the cell to two phase-coherent microwave pulses. In this case the resonance line has a width characteristic of the pulse-repetition frequency which can be made several times smaller than the natural line width in the cell. Proper timing of the sequence of microwave pulses and light pulses for optical pumping is necessary to conserve phase coherence and to obtain a well-defined Ramsey pattern. Results of the tests on a laboratory model using Rubidium-87 atoms show the elimination of the light shifts and an improvement of the short-term stability of the crystal oscillator by one order of magnitude.