Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Physics Conference Series

Control system high-precision laser to obtain the ensemble of ultracold ions Th3+

V. V. Florentsev, V Yu Zhdamirov, I. I. Rod’ko, Nikolay A. Borodulya, Aleksandr Pavlovich Biryukov

Published Jan 1, 2018• 1 citation
Publisher

Abstract

One of key problems of nuclear standard frequency development is preparation assembly of ultracold thorium ions in Pauli trap. In this case semiconductive frequency-stabilized lasers with external resonator on frequencies 690 nm, 984 nm, and 1088 nm are used for excitation of corresponding electronic dipole and quadrupole cooling transitions for Th3+ ions. In the paper the results of development and creation of unified laser module, which is able to be used as base for full-featured system designed for laser cooling of Th3+ ions, are presented. The module is able to fine-tune necessary wavelength with accuracy ±5 nm.

DOI
10.1088/1742-6596/944/1/012037

Related papers

Trapping and sympathetic cooling of Th3+ ions in a linear ion trap

Zi Li, Wen-Ting Gan, Chen Wang +3 more

We demonstrate a modified integration of a linear ion trap with a time-of-flight mass spectrometer optimized to enhance the loading and detection of Th3+ ions. A phase-locked radiofrequency/high-voltage switch incorporating zero-crossing triggering and a programmable time delay is a key upgrade to minimize RF phase-dependent jitter and enable the unambiguous identification of Th3+ ions. To enhance purity, yield, and lifetime of trapped Th3+ ions, we optimize the ion loading parameters, including ion trap settings (RF amplitude, endcap voltages, and loading time), laser-ablation pulse energy, helium partial pressure, and ion storage time. These improvements extend trapping lifetimes of Th3+ ions to several hundred seconds, representing an order-of-magnitude increase compared to our previous work. Finally, single-pulse ablation of mixed Sr–Th nitrate targets enables the direct co-loading of Th3+ and 88Sr+ ions, and subsequent laser cooling forms multi-component Coulomb crystals for laser spectroscopy of Th3+ ions. Given the long trapping lifetime of Th3+ ions, this system will serve as a platform for developing a prototype trap-based thorium nuclear clock.

Journal of Applied Physics•Dec 9, 2025•2 citations

Spectroscopy of Single Trapped Ions and Application to Frequency Standards

HERBERT WALTHER

Single ions trapped and laser cooled provide ideal objects for high resolution spectroscopy and frequency standards. For the latter purpose we are investigating the 5s2 1S0 → 5s5p 3P0 transition of In+. With a natural linewidth of only 1.1 Hz this resonance offers very high resolution and is highly immune to frequency shifts due to external electromagnetic fields, because it connects two levels with vanishing electronic magnetic momenta [1]. The wavelength of this clock transition is 236.5 nm and is technically very convenient, since it coincides with the fourth harmonic of the 946 nm Nd:YAG laser line. So this intrinsically frequency stable solid-state laser can be used to excite the transition [2]. For laser cooling and fluorescence detection of the indium ion the 5s2 1So -> 5s5p 3P1 transition at 230.6 nm can be employed. The use of the relatively narrow intercombination line for laser cooling allows us to study optical sideband cooling in the strong binding regime, where the oscillation frequencies of the ion in the trap (around 1 MHz) are larger than the optical linewidth of 360 kHz. In this parameter range laser cooling is possible to the quantum ground state of the vibrational motion in the trap corresponding to a temperature of roughly 100 μK. The same low temperature was obtained with sideband cooling of a small Coulomb crystal consisting of two ions, creating an interesting new quantum few-particle system.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jan 1, 1998•0 citations

High-accuracy frequency standards using laser-cooled Hg+ ions

Dana J. Berkeland, J.D. Miller, Brent C. Young +3 more

We discuss frequency standards based on laser-cooled 199Hg+ ions confined in cryogenic rf traps. In one experiment, the frequency of a microwave source is served to the ions' ground-state hyperfine transition at 40.5 GHz. For seven ions and a Ramsey free precession time of 100 s, the fractional frequency stability is 3.3 (2) X 10-13 (tau) -1/2 for measurement times (tau) < 2 h. The ground-state hyperfine interval is measured to be 40 507 347 996.841 59 (14) (41) Hz, where the first number in parentheses is the uncertainty due to statistics and systematic errors, and the second is the uncertainty in the frequency of the time scale to which the standard is compared. In a second experiment under development, a strong-binding cryogenic trap will confine a single ion used for an optical frequency standard based on a narrow electric quadrupole transition at 282 nm. The bandwidth of the laser used to drive this transition is less than 10 Hz at 563 nm.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 15, 1998•1 citation

Single ion optical frequency standard

Jonas Bergquist, Wayne M. Itano, David J. Wineland +3 more

Experimental research toward the realization of an optical frequency standard of high accuracy is briefly reviewed. The studies concentrated on single, laser-cooled ions since they offer several attractive features for the achievement of high accuracy. These features include long storage time which eliminates transit-time broadening, confinement that is nearly nonperturbative to the internal level structure of the ion, laser-cooling that reduces motional shifts to small values, and electron-shelving whereby transitions to long-lived states can be detected with unit probability. The authors studied spectroscopically the electric-quadrupole allowed transition at 282 nm in a single, laser-cooled /sup 199/Hg/sup +/ ion stored in an RF Paul trap with extremely high resolution. The measured linewidth is limited by the spectral purity of the laser to about 80 Hz. Possible improvements and future directions are discussed.>

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 1, 1991•8 citations

A cryogenic linear ion trap for /sup 199/Hg/sup +/ frequency standards

J.D. Miller, M.E. Poitzsch, Flávio C. Cruz +4 more

A cryogenic linear rf trap has been constructed to study the accuracy of a clock based on laser cooled /sup 199/Hg/sup +/. Crystals of tens of ions have been observed. The residual micromotion of the ions has been minimized and Ramsey interrogation periods of 25 s have been demonstrated for the 40.5 GHz transition. This system should eventually provide a frequency standard of high precision and accuracy. We report on the development of compact, efficient, solid-state sources at 194 nm and 282 nm for laser cooling of /sup 199/Hg/sup +/ and investigation of the /sup 2/S/sub 1/2//spl rarr//sup 2/D/sub 5/2/ quadrupole transition of interest for an optical frequency standard.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 19, 2002•0 citations

Narrow-linewidth laser system for precise spectroscopy of the indium ion clock transition

Alexander Yu. Nevsky, M. Eichenseer, E. Peik +2 more

Summary form only given. A single laser-cooled indium ion, stored in a radio-frequency trap, is expected to be one of the most promising candidates for the creation of a new generation of optical frequency standards with an anticipated accuracy of up to 10/sup -18/. On the way to achieving such a high level of accuracy, one of the main limitations is the short-term frequency instability of the laser system, used to excite the narrow /sup 1/S/sub 0/-/sup 3/P/sub 0/ In/sup +/ clock transition. Since the signal from the single ion is small, the laser system should posses extremely high frequency stability (on the level of /spl Delta/v/v=10/sup -14//spl divide/10/sup -15/) for averaging times of about one second in order to reduce statistical uncertainties and to minimize the time of experiment. In this paper, we report our recent results on the improvement of the short-term frequency stability of the laser system.

Quantum Electronics and Laser Science Conference•Nov 13, 2002•0 citations
One of key problems of nuclear standard frequency development is preparation assembly of ultracold thorium ions in Pauli trap. In this case semiconductive frequency-stabilized lasers with external resonator on frequencies 690 nm, 984 nm, and 1088 nm are used for excitation of corresponding electronic dipole and quadrupole cooling transitions for Th3+ ions. In the paper the results of development and creation of unified laser module, which is able to be used as base for full-featured system designed for laser cooling of Th3+ ions, are presented. The module is able to fine-tune necessary wavelength with accuracy ±5 nm.
We demonstrate a modified integration of a linear ion trap with a time-of-flight mass spectrometer optimized to enhance the loading and detection of Th3+ ions. A phase-locked radiofrequency/high-voltage switch incorporating zero-crossing triggering and a programmable time delay is a key upgrade to minimize RF phase-dependent jitter and enable the unambiguous identification of Th3+ ions. To enhance purity, yield, and lifetime of trapped Th3+ ions, we optimize the ion loading parameters, including ion trap settings (RF amplitude, endcap voltages, and loading time), laser-ablation pulse energy, helium partial pressure, and ion storage time. These improvements extend trapping lifetimes of Th3+ ions to several hundred seconds, representing an order-of-magnitude increase compared to our previous work. Finally, single-pulse ablation of mixed Sr–Th nitrate targets enables the direct co-loading of Th3+ and 88Sr+ ions, and subsequent laser cooling forms multi-component Coulomb crystals for laser spectroscopy of Th3+ ions. Given the long trapping lifetime of Th3+ ions, this system will serve as a platform for developing a prototype trap-based thorium nuclear clock.
Single ions trapped and laser cooled provide ideal objects for high resolution spectroscopy and frequency standards. For the latter purpose we are investigating the 5s2 1S0 → 5s5p 3P0 transition of In+. With a natural linewidth of only 1.1 Hz this resonance offers very high resolution and is highly immune to frequency shifts due to external electromagnetic fields, because it connects two levels with vanishing electronic magnetic momenta [1]. The wavelength of this clock transition is 236.5 nm and is technically very convenient, since it coincides with the fourth harmonic of the 946 nm Nd:YAG laser line. So this intrinsically frequency stable solid-state laser can be used to excite the transition [2]. For laser cooling and fluorescence detection of the indium ion the 5s2 1So -> 5s5p 3P1 transition at 230.6 nm can be employed. The use of the relatively narrow intercombination line for laser cooling allows us to study optical sideband cooling in the strong binding regime, where the oscillation frequencies of the ion in the trap (around 1 MHz) are larger than the optical linewidth of 360 kHz. In this parameter range laser cooling is possible to the quantum ground state of the vibrational motion in the trap corresponding to a temperature of roughly 100 μK. The same low temperature was obtained with sideband cooling of a small Coulomb crystal consisting of two ions, creating an interesting new quantum few-particle system.
We discuss frequency standards based on laser-cooled 199Hg+ ions confined in cryogenic rf traps. In one experiment, the frequency of a microwave source is served to the ions' ground-state hyperfine transition at 40.5 GHz. For seven ions and a Ramsey free precession time of 100 s, the fractional frequency stability is 3.3 (2) X 10-13 (tau) -1/2 for measurement times (tau) < 2 h. The ground-state hyperfine interval is measured to be 40 507 347 996.841 59 (14) (41) Hz, where the first number in parentheses is the uncertainty due to statistics and systematic errors, and the second is the uncertainty in the frequency of the time scale to which the standard is compared. In a second experiment under development, a strong-binding cryogenic trap will confine a single ion used for an optical frequency standard based on a narrow electric quadrupole transition at 282 nm. The bandwidth of the laser used to drive this transition is less than 10 Hz at 563 nm.
Experimental research toward the realization of an optical frequency standard of high accuracy is briefly reviewed. The studies concentrated on single, laser-cooled ions since they offer several attractive features for the achievement of high accuracy. These features include long storage time which eliminates transit-time broadening, confinement that is nearly nonperturbative to the internal level structure of the ion, laser-cooling that reduces motional shifts to small values, and electron-shelving whereby transitions to long-lived states can be detected with unit probability. The authors studied spectroscopically the electric-quadrupole allowed transition at 282 nm in a single, laser-cooled /sup 199/Hg/sup +/ ion stored in an RF Paul trap with extremely high resolution. The measured linewidth is limited by the spectral purity of the laser to about 80 Hz. Possible improvements and future directions are discussed.>
A cryogenic linear rf trap has been constructed to study the accuracy of a clock based on laser cooled /sup 199/Hg/sup +/. Crystals of tens of ions have been observed. The residual micromotion of the ions has been minimized and Ramsey interrogation periods of 25 s have been demonstrated for the 40.5 GHz transition. This system should eventually provide a frequency standard of high precision and accuracy. We report on the development of compact, efficient, solid-state sources at 194 nm and 282 nm for laser cooling of /sup 199/Hg/sup +/ and investigation of the /sup 2/S/sub 1/2//spl rarr//sup 2/D/sub 5/2/ quadrupole transition of interest for an optical frequency standard.
Summary form only given. A single laser-cooled indium ion, stored in a radio-frequency trap, is expected to be one of the most promising candidates for the creation of a new generation of optical frequency standards with an anticipated accuracy of up to 10/sup -18/. On the way to achieving such a high level of accuracy, one of the main limitations is the short-term frequency instability of the laser system, used to excite the narrow /sup 1/S/sub 0/-/sup 3/P/sub 0/ In/sup +/ clock transition. Since the signal from the single ion is small, the laser system should posses extremely high frequency stability (on the level of /spl Delta/v/v=10/sup -14//spl divide/10/sup -15/) for averaging times of about one second in order to reduce statistical uncertainties and to minimize the time of experiment. In this paper, we report our recent results on the improvement of the short-term frequency stability of the laser system.