Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Journal of Lasers

Progress in Biomagnetic Signal Measurements with Ultra-Sensitive Atomic Magnetometers

王晓飞 Wang Xiaofei, 孙献平 Sun Xianping, 赵修超 Zhao Xiuchao, 朱茂华 Zhu Maohua, 叶朝辉 Ye Chaohui, 周欣 Zhou Xin

Published Jan 1, 2018• 3 citations
Publisher
DOI
10.3788/cjl201845.0207012

Related papers

A portable ultrasensitive atomic magnetometer for biomagnetic measurements

Robert Wyllie, Zhimin Li, Ronald T. Wakai +3 more

Bulletin of the American Physical Society•Jun 6, 2007•0 citations

Progress in high sensitive atomic magnetometers

Guobin Liu, Xian-Ping Sun, 顾思洪 +2 more

Wuli•Jan 1, 2012•1 citation

Broadband Ultra-Sensitive Adiabatic Magnetometer

Igor Savukov, Young Jin Kim

We introduce a new ultra-sensitive adiabatic magnetometer that has a broad bandwidth and can operate in the presence of magnetic fields and gradients. It follows conceptually typical implementations of atomic magnetometers based on alkali-metal vapor cells and lasers for optical pumping and optical Faraday effect detection, while its unique feature is a measurement of an oscillating magnetic field along the probe beam direction at frequencies lower than the resonant frequency, proportional to a static magnetic field along the pump beam direction. The bandwidth of the adiabatic magnetometer scales as the strength of the field along the pump beam. From our theoretical studies it is expected that the adiabatic magnetometer can reach 1 fT sensitivity with a bandwidth of 10 kHz, which any type of atomic magnetometers cannot achieve. Among anticipated various applications of this adiabatic magnetometer are biomagnetic sensing, nuclear magnetic resonance detection, and alkali-metal density measurements. We experimentally conducted alkali-metal density measurements, as an example of applications.

IEEE Sensors Applications Symposium (SAS)•Aug 23, 2021•1 citation

A Triaxial Dual‐Beam Magnetic Measurement Method Based on Dressed‐Atom Dynamic Evolution Behavior for Miniaturized SERF Atomic Magnetometer

Zhen Li, Xiangyang Zhou, Zihao Lyu +4 more

ABSTRACT Miniaturized spin‐exchange relaxation‐free (SERF) atomic magnetometers have become core sensors for detecting biomagnetic fields, including MEG and MCG, due to their ultra‐high sensitivity and high spatiotemporal resolution. Compared to single‐axis magnetometers, triaxial atomic magnetometers are more attractive which can measure comprehensive three‐dimensional magnetic field information. However, traditional triaxial single‐beam or dual‐beam configurations are constrained by limited longitudinal sensitivity or complex optical architectures unsuitable for miniaturized sensors. In this paper, a triaxial dual‐beam magnetic measurement method based on the dynamic evolution of dressed atoms is proposed. The proposed method employs an overlapping pump–probe configuration to simplify the optical sensing architecture while maintaining high magnetic field sensitivity. By utilizing multi‐frequency signal modulation and parallel demodulation, triaxial magnetic vector components are measured simultaneously. Modulation parameters are experimentally optimized based on a systematic analysis of atomic spin dynamics under dual radio‐frequency (RF) fields. Triaxial couplings under various bias magnetic fields are quantitatively analyzed. Experimental validation using a 4 mm vapor cell demonstrates simultaneous triaxial magnetic field measurements, achieving sensitivities of 84.4, 73.2, and 190.7 fT/Hz 1/2 and corresponding bandwidths of 65, 76, and 78 Hz along the x ‐, y ‐, and z ‐axes, respectively.

Advanced Quantum Technologies•Nov 1, 2026•0 citations

Magnetic Resonance Based Atomic Magnetometers

Antoine Weis, G. Bison, Z. D. Grujić

Smart sensors, measurement and instrumentation•Sep 20, 2016•28 citations

Flat-response spin-exchange relaxation free atomic magnetometer under negative feedback

Hyun Joon Lee, Jeong Hyun Shim, Han Seb Moon +1 more

We demonstrate that the use of negative feedback extends the detection bandwidth of an atomic magnetometer in a spin-exchange relaxation free (SERF) regime. A flat-frequency response from zero to 190 Hz was achieved, which is nearly a three-fold enhancement while maintaining sensitivity, 3 fT/Hz1/2 at 100 Hz. With the extension of the bandwidth, the linear correlation between measured signals and a magne-tocardiographic field synthesized for comparison was increased from 0.21 to 0.74. This result supports the feasibility of measuring weak biomagnetic signals containing multiple frequency components using a SERF atomic magnetometer under negative feedback.

Optics Express•Aug 11, 2014•57 citations
We introduce a new ultra-sensitive adiabatic magnetometer that has a broad bandwidth and can operate in the presence of magnetic fields and gradients. It follows conceptually typical implementations of atomic magnetometers based on alkali-metal vapor cells and lasers for optical pumping and optical Faraday effect detection, while its unique feature is a measurement of an oscillating magnetic field along the probe beam direction at frequencies lower than the resonant frequency, proportional to a static magnetic field along the pump beam direction. The bandwidth of the adiabatic magnetometer scales as the strength of the field along the pump beam. From our theoretical studies it is expected that the adiabatic magnetometer can reach 1 fT sensitivity with a bandwidth of 10 kHz, which any type of atomic magnetometers cannot achieve. Among anticipated various applications of this adiabatic magnetometer are biomagnetic sensing, nuclear magnetic resonance detection, and alkali-metal density measurements. We experimentally conducted alkali-metal density measurements, as an example of applications.
ABSTRACT Miniaturized spin‐exchange relaxation‐free (SERF) atomic magnetometers have become core sensors for detecting biomagnetic fields, including MEG and MCG, due to their ultra‐high sensitivity and high spatiotemporal resolution. Compared to single‐axis magnetometers, triaxial atomic magnetometers are more attractive which can measure comprehensive three‐dimensional magnetic field information. However, traditional triaxial single‐beam or dual‐beam configurations are constrained by limited longitudinal sensitivity or complex optical architectures unsuitable for miniaturized sensors. In this paper, a triaxial dual‐beam magnetic measurement method based on the dynamic evolution of dressed atoms is proposed. The proposed method employs an overlapping pump–probe configuration to simplify the optical sensing architecture while maintaining high magnetic field sensitivity. By utilizing multi‐frequency signal modulation and parallel demodulation, triaxial magnetic vector components are measured simultaneously. Modulation parameters are experimentally optimized based on a systematic analysis of atomic spin dynamics under dual radio‐frequency (RF) fields. Triaxial couplings under various bias magnetic fields are quantitatively analyzed. Experimental validation using a 4 mm vapor cell demonstrates simultaneous triaxial magnetic field measurements, achieving sensitivities of 84.4, 73.2, and 190.7 fT/Hz 1/2 and corresponding bandwidths of 65, 76, and 78 Hz along the x ‐, y ‐, and z ‐axes, respectively.
We demonstrate that the use of negative feedback extends the detection bandwidth of an atomic magnetometer in a spin-exchange relaxation free (SERF) regime. A flat-frequency response from zero to 190 Hz was achieved, which is nearly a three-fold enhancement while maintaining sensitivity, 3 fT/Hz1/2 at 100 Hz. With the extension of the bandwidth, the linear correlation between measured signals and a magne-tocardiographic field synthesized for comparison was increased from 0.21 to 0.74. This result supports the feasibility of measuring weak biomagnetic signals containing multiple frequency components using a SERF atomic magnetometer under negative feedback.