Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Letters

Detection of stably bright squeezed light with the quantum noise reduction of 126 dB by mutually compensating the phase fluctuations

Wenhai Yang, Shaoping Shi, Yajun Wang, Weiguang Ma, Yaohui Zheng, Kunchi Peng

Published Oct 30, 2017• 81 citations
Publisher

Abstract

We present a mutual compensation scheme of three phase fluctuations, originating from the residual amplitude modulation (RAM) in the phase modulation process, in the bright squeezed light generation system. The influence of the RAM on each locking loop is harmonized by using one electro-optic modulator (EOM), and the direction of the phase fluctuation is manipulated by positioning the photodetector (PD) that extracts the error signal before or after the optical parametric amplifier (OPA). Therefore a bright squeezed light with non-classical noise reduction of π is obtained. By fitting the squeezing and antisqueezing measurement results, we confirm that the total phase fluctuation of the system is around 3.1 mrad. The fluctuation of the noise suppression is 0.2 dB for 3 h.

DOI
10.1364/ol.42.004553

Related papers

Investigation of residual amplitude modulation in squeezed state generation system

Zhixiu Li, Xiaocong Sun, Yajun Wang +2 more

We present an analysis on how the optical parametric oscillator (OPO) detuning and the relative phase drift deteriorate the stability of the squeezed states, including the output power and the squeezed degree, and investigate the influence of RAM on the cavity detuning and the relative phase drift under different cases. Subsequently, the RAM is experimentally measured. In term of the measurement results, we perform a comparative study about RAM's influence on the cavity and phase locking in two cases. As a result, with the error signal extracted from the transmission of the OPO, the output power stability of the squeezed light is greatly improved. With the phase modulation imposed on the signal beam, the long-term stability of the squeezed degree is significantly enhanced.

Optics Express•Jul 10, 2018•10 citations

Amplitude squeezing of light by means of a phase-sensitive fiber parametric amplifier

Dmitry Levandovsky, Michael Vasilyev, Prem Kumar

We experimentally demonstrate generation of bright sub-Poissonian light by means of parametric deamplification in a phase-sensitive fiber amplifier that is based on a balanced nonlinear Sagnac interferometer. On direct detection, the photocurrent noise falls below the shot-noise limit by (0.6 +/- 0.2) dB (1.4 dB when corrected for detection losses). To observe the noise reduction we employed a scheme that used two orthogonally polarized pulses to cancel the noise that arises from the predominantly polarized guided-acoustic-wave Brillouin scattering in the fiber. We also present a simplified semiclassical theory of quantum-noise suppression by this amplifier, which is found to be in good agreement with the experimental results.

Optics Letters•Jul 15, 1999•66 citations

A Bright Squeezed Light Source for Quantum Sensing

Wenhai Yang, Wenting Diao, Chunxiao Cai +8 more

The use of optical sensing for in vivo applications is compelling, since it offers the advantages of non-invasiveness, non-ionizing radiation, and real-time monitoring. However, the signal-to-noise ratio (SNR) of the optical signal deteriorates dramatically as the biological tissue increases. Although increasing laser power can improve the SNR, intense lasers can severely disturb biological processes and viability. Quantum sensing with bright squeezed light can make the measurement sensitivity break through the quantum noise limit under weak laser conditions. A bright squeezed light source is demonstrated to avoid the deterioration of SNR and biological damage, which integrates an external cavity frequency-doubled laser, a semi-monolithic standing cavity with periodically poled titanyl phosphate (PPKTP), and a balanced homodyne detector (BHD) assembled on a dedicated breadboard. With the rational design of the mechanical elements, the optical layout, and the feedback control equipment, a maximum non-classical noise reduction of −10.7 ± 0.2 dB is observed. The average squeeze of −10 ± 0.2 dB in continuous operation for 60 min is demonstrated. Finally, the intracavity loss of degenerate optical parametric amplifier (DOPA) and the initial bright squeezed light can be calculated to be 0.0021 and −15.5 ± 0.2 dB, respectively. Through the above experimental and theoretical analysis, the direction of improving bright squeeze level is pointed out.

Chemosensors•Dec 25, 2022•14 citations

Locking the phase of balanced homodyne detection system for squeezed light

Zhang Yan, Xudong Yu, Ke Di Ma +2 more

The balanced homodyne detection technique is an important method to detect the quantum light field. The signal light injected into the phase sensitive optical parameter amplifier (OPA) is phase modulated. The output squeezed light of OPA is detected by the balanced homodyne detection system. When the phase sensitive OPA is operated at parametric amplification and deamplification respectively, we can judge which quadrature component of the quantum light field is measured by observing the modulation signal. We can demodulate the phase modulation signal to achieve the error signal, which is used to lock the relative phase of zero between the local and the quantum light fields (corresponding to the quadrature-amplitude of the unknown light field).

Acta Physica Sinica•Jan 1, 2013•8 citations

Generation of 10-dB squeezed light from a broadband waveguide optical parametric amplifier with improved phase locking method

Kazuki Hirota, Takahiro Kashiwazaki, Gyeongmin Ha +10 more

We report generation of 10.1\pm0.2-dB squeezed light from a broadband periodically poled lithium niobate (PPLN) waveguide optical parametric amplifier (OPA). Based on our previous report where a similar PPLN waveguide shows 8.3-dB squeezing [T. Kashiwazaki et al., Appl. Phys. Lett. 122, 234003 (2023)], we reduce phase fluctuations and overall optical losses in the measurement system. In particular, we introduce a novel phase detection technique that does not require tapping a part of the squeezed light to get a phase locking signal. We use a phase-detection OPA seeded by a tapped probe and pump light before a squeezer OPA. This configuration breaks the conventional trade-off between generating a phase-locking signal with high-signal-to-noise ratio and suppressing degradation of squeezing level caused by optical tapping. With all these improvements, the phase fluctuation angle is reduced from 14 mrad to 9 mrad, and the total optical loss from 12\% to 8\%. Achieving more than 10 dB of squeezing by the broadband waveguide OPA is a significant step towards realization of fault-tolerant ultra-fast universal optical quantum computation.

quant-pharXiv:2511.15082•Optics Express•Nov 20, 2025•11 citations

Observation of a bright squeezed quantum frequency comb in nanophotonics

Yichen Shen, Ping‐Yen Hsieh, Dhruv Srinivasan +5 more

We present the first bright amplitude-squeezed frequency comb using an on-chip Si3N4 optical parametric amplifier. We demonstrate 6 pairs of two-mode-squeezed states (12 qumodes) with a maximum 4 dB of directly detected quantum noise reduction.

Conference on Lasers and Electro-Optics•Jan 1, 2025•0 citations
We present a mutual compensation scheme of three phase fluctuations, originating from the residual amplitude modulation (RAM) in the phase modulation process, in the bright squeezed light generation system. The influence of the RAM on each locking loop is harmonized by using one electro-optic modulator (EOM), and the direction of the phase fluctuation is manipulated by positioning the photodetector (PD) that extracts the error signal before or after the optical parametric amplifier (OPA). Therefore a bright squeezed light with non-classical noise reduction of π is obtained. By fitting the squeezing and antisqueezing measurement results, we confirm that the total phase fluctuation of the system is around 3.1 mrad. The fluctuation of the noise suppression is 0.2 dB for 3 h.
We present an analysis on how the optical parametric oscillator (OPO) detuning and the relative phase drift deteriorate the stability of the squeezed states, including the output power and the squeezed degree, and investigate the influence of RAM on the cavity detuning and the relative phase drift under different cases. Subsequently, the RAM is experimentally measured. In term of the measurement results, we perform a comparative study about RAM's influence on the cavity and phase locking in two cases. As a result, with the error signal extracted from the transmission of the OPO, the output power stability of the squeezed light is greatly improved. With the phase modulation imposed on the signal beam, the long-term stability of the squeezed degree is significantly enhanced.
We experimentally demonstrate generation of bright sub-Poissonian light by means of parametric deamplification in a phase-sensitive fiber amplifier that is based on a balanced nonlinear Sagnac interferometer. On direct detection, the photocurrent noise falls below the shot-noise limit by (0.6 +/- 0.2) dB (1.4 dB when corrected for detection losses). To observe the noise reduction we employed a scheme that used two orthogonally polarized pulses to cancel the noise that arises from the predominantly polarized guided-acoustic-wave Brillouin scattering in the fiber. We also present a simplified semiclassical theory of quantum-noise suppression by this amplifier, which is found to be in good agreement with the experimental results.
The use of optical sensing for in vivo applications is compelling, since it offers the advantages of non-invasiveness, non-ionizing radiation, and real-time monitoring. However, the signal-to-noise ratio (SNR) of the optical signal deteriorates dramatically as the biological tissue increases. Although increasing laser power can improve the SNR, intense lasers can severely disturb biological processes and viability. Quantum sensing with bright squeezed light can make the measurement sensitivity break through the quantum noise limit under weak laser conditions. A bright squeezed light source is demonstrated to avoid the deterioration of SNR and biological damage, which integrates an external cavity frequency-doubled laser, a semi-monolithic standing cavity with periodically poled titanyl phosphate (PPKTP), and a balanced homodyne detector (BHD) assembled on a dedicated breadboard. With the rational design of the mechanical elements, the optical layout, and the feedback control equipment, a maximum non-classical noise reduction of −10.7 ± 0.2 dB is observed. The average squeeze of −10 ± 0.2 dB in continuous operation for 60 min is demonstrated. Finally, the intracavity loss of degenerate optical parametric amplifier (DOPA) and the initial bright squeezed light can be calculated to be 0.0021 and −15.5 ± 0.2 dB, respectively. Through the above experimental and theoretical analysis, the direction of improving bright squeeze level is pointed out.
The balanced homodyne detection technique is an important method to detect the quantum light field. The signal light injected into the phase sensitive optical parameter amplifier (OPA) is phase modulated. The output squeezed light of OPA is detected by the balanced homodyne detection system. When the phase sensitive OPA is operated at parametric amplification and deamplification respectively, we can judge which quadrature component of the quantum light field is measured by observing the modulation signal. We can demodulate the phase modulation signal to achieve the error signal, which is used to lock the relative phase of zero between the local and the quantum light fields (corresponding to the quadrature-amplitude of the unknown light field).
We report generation of 10.1\pm0.2-dB squeezed light from a broadband periodically poled lithium niobate (PPLN) waveguide optical parametric amplifier (OPA). Based on our previous report where a similar PPLN waveguide shows 8.3-dB squeezing [T. Kashiwazaki et al., Appl. Phys. Lett. 122, 234003 (2023)], we reduce phase fluctuations and overall optical losses in the measurement system. In particular, we introduce a novel phase detection technique that does not require tapping a part of the squeezed light to get a phase locking signal. We use a phase-detection OPA seeded by a tapped probe and pump light before a squeezer OPA. This configuration breaks the conventional trade-off between generating a phase-locking signal with high-signal-to-noise ratio and suppressing degradation of squeezing level caused by optical tapping. With all these improvements, the phase fluctuation angle is reduced from 14 mrad to 9 mrad, and the total optical loss from 12\% to 8\%. Achieving more than 10 dB of squeezing by the broadband waveguide OPA is a significant step towards realization of fault-tolerant ultra-fast universal optical quantum computation.