Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics

Phase sensing beyond standard quantum limit with a truncated SU(1,1) interferometer

P. Gupta, Brian E. Anderson, Bonnie L. Schmittberger, Travis Horrom, Carla Hermann-Avigliano, K. M. Jones, Paul D. Lett

Published Jan 1, 2017• 0 citations
Publisher

Abstract

We present an SU(1,1) interferometer variation where the second nonlinear interaction is replaced with homodyne detection. Sensitivity measurements as a function of phase demonstrate that our device beats the standard quantum limit by 4dB.
DOI
10.1364/cleo_at.2017.jth2a.73

Related papers

Phase sensing with a truncated SU(1,1) interferometer

P. Gupta, Brian E. Anderson, Bonnie L. Schmittberger +4 more

We present an SU(1,1) interferometer variation by replacing the second nonlinear interaction with the homodyne detection and demonstrate an improvement in phase sensitivity over the standard quantum limit.

Frontiers in Optics•Jan 1, 2017•1 citation

Phase sensing beyond the standard quantum limit with a variation on the SU(1,1) interferometer

Brian E. Anderson, Prasoon Gupta, Bonnie L. Schmittberger +4 more

An SU(1,1) interferometer replaces the beamsplitters in a Mach-Zehnder interferometer with nonlinear interactions and offers the potential of achieving high phase sensitivity in applications with low optical powers. We present a novel variation in which the second nonlinear interaction is replaced with balanced homodyne detection. The phase-sensing quantum state is a two-mode squeezed state produced by seeded four-wave-mixing in Rb vapor. Measurements as a function of operating point show that even with $\approx35~\%$ loss this device can surpass the standard quantum limit by 4~dB.

arXiv:1610.06891•Optica•Jun 30, 2017•168 citations

Optimized phase sensing in a truncated SU(1,1) interferometer

Prasoon Gupta, Bonnie L. Schmittberger, Brian E. Anderson +2 more

Homodyne detection is often used for interferometers based on nonlinear optical gain media. For the configuration of a seeded, "truncated SU(1,1)" interferometer Anderson, et al. [ Phys. Rev. A95, 063843 (2017)] showed how to optimize the homodyne detection scheme and demonstrated theoretically that it can saturate the quantum Cramer-Rao bound for phase estimation. In this work we extend those results by taking into account loss in the truncated SU(1,1) interferometer and determining the optimized homodyne detection scheme for phase measurement. Further, we build a truncated SU(1,1) interferometer and experimentally demonstrate that this optimized scheme achieves a reduction in noise level, corresponding to an enhanced potential phase sensitivity, compared to a typical homodyne detection scheme for a two-mode squeezed state. In doing so, we also demonstrate an improvement in the degree to which we can beat the standard quantum limit with this device.

arXiv:1802.04314•Optics Express•Jan 4, 2018•58 citations

Phase sensitivity approaching the quantum Cramér-Rao bound in a modified SU(1,1) interferometer

Jiandong Zhang, Chenglong You, Chuang Li +1 more

SU(1,1) interferometers, based on the usage of nonlinear elements, are superior to passive interferometers in phase sensitivity. However, the SU(1,1) interferometer cannot make full use of photons carrying phase information as the second nonlinear element annihilates some of the photons inside. Here we focus on improving phase sensitivity and propose a different protocol based on a modified SU(1,1) interferometer, where the second nonlinear element is replaced by a beam splitter. We utilize two coherent states as inputs and implement balanced homodyne measurement at the output. Our analysis suggests that the protocol we propose can achieve the sub-shot-noise-limited phase sensitivity and is robust against photon loss as well as background noise. Our work is important for practical quantum metrology using SU(1,1) interferometers.

arXiv:2012.04236•Physical Review A•Mar 29, 2021•35 citations

PHASE MEASUREMENTS WITH A TWO-MODE SQUEEZED STATE OF LIGHT.

Gupta, Prasoon

Introducing squeezed states of light into interferometers can increase the phase sensitivity of the device beyond the standard quantum limit (SQL). We discuss an SU(1,1) interferometer, where nonlinear optical elements replace the beam splitters in a Mach-Zehnder interferometer. A two-mode squeezed state of light is generated inside of such an interferometer. We talk about the phase sensitivities of an SU(1,1) interferometer with different detection schemes and their improvement over the SQL. We also discuss the concept of an optimal detection scheme for phase measurement in an interferometer. We describe a modification of the SU(1,1) interferometer which reduces the experimental complexities while giving the same phase sensitivity. We call the design a truncated SU(1,1) interferometer. We show our experimental results of 4 dB improvement in phase sensitivity over the SQL using a truncated SU(1,1) interferometer. We also compare the theoretical sensitivities of vacuum-seeded configurations of a conventional and a truncated SU(1,1) interferometer, and show our experimental results for the phase sensitivity of the truncated version. We explain the dependence of phase sensitivity on the measurement of squeezing. We talk about the methods to improve the measurement of squeezing in a 4-wave mixing experiment, and our efforts in implementing them. Finally, we mention our progress in measuring a big phase shift using an adaptive algorithm in the truncated SU(1,1) interferometer, and discuss the technicalities involved in big phase measurements.

•Jan 1, 2019•0 citations

Optimal phase measurements with bright- and vacuum-seeded SU(1,1) interferometers

Brian E. Anderson, Bonnie L. Schmittberger, Prasoon Gupta +2 more

The SU(1,1) interferometer can be thought of as a Mach-Zehnder interferometer with its linear beam splitters replaced with parametric nonlinear optical processes. We consider the cases of bright- and vacuum-seeded SU(1,1) interferometers using intensity or homodyne detectors. A simplified truncated scheme with only one nonlinear interaction is introduced, which not only beats conventional intensity detection with a bright seed, but can saturate the phase-sensitivity bound set by the quantum Fisher information. We also show that the truncated scheme achieves a sub-shot-noise phase sensitivity in the vacuum-seeded case, despite the phase-sensing optical beams having no well-defined phase.

arXiv:1704.04261•Physical Review A•Jun 27, 2017•93 citations
An SU(1,1) interferometer replaces the beamsplitters in a Mach-Zehnder interferometer with nonlinear interactions and offers the potential of achieving high phase sensitivity in applications with low optical powers. We present a novel variation in which the second nonlinear interaction is replaced with balanced homodyne detection. The phase-sensing quantum state is a two-mode squeezed state produced by seeded four-wave-mixing in Rb vapor. Measurements as a function of operating point show that even with ≈35 %\approx35~\%≈35 % loss this device can surpass the standard quantum limit by 4~dB.
Homodyne detection is often used for interferometers based on nonlinear optical gain media. For the configuration of a seeded, "truncated SU(1,1)" interferometer Anderson, et al. [ Phys. Rev. A95, 063843 (2017)] showed how to optimize the homodyne detection scheme and demonstrated theoretically that it can saturate the quantum Cramer-Rao bound for phase estimation. In this work we extend those results by taking into account loss in the truncated SU(1,1) interferometer and determining the optimized homodyne detection scheme for phase measurement. Further, we build a truncated SU(1,1) interferometer and experimentally demonstrate that this optimized scheme achieves a reduction in noise level, corresponding to an enhanced potential phase sensitivity, compared to a typical homodyne detection scheme for a two-mode squeezed state. In doing so, we also demonstrate an improvement in the degree to which we can beat the standard quantum limit with this device.
SU(1,1) interferometers, based on the usage of nonlinear elements, are superior to passive interferometers in phase sensitivity. However, the SU(1,1) interferometer cannot make full use of photons carrying phase information as the second nonlinear element annihilates some of the photons inside. Here we focus on improving phase sensitivity and propose a different protocol based on a modified SU(1,1) interferometer, where the second nonlinear element is replaced by a beam splitter. We utilize two coherent states as inputs and implement balanced homodyne measurement at the output. Our analysis suggests that the protocol we propose can achieve the sub-shot-noise-limited phase sensitivity and is robust against photon loss as well as background noise. Our work is important for practical quantum metrology using SU(1,1) interferometers.
Introducing squeezed states of light into interferometers can increase the phase sensitivity of the device beyond the standard quantum limit (SQL). We discuss an SU(1,1) interferometer, where nonlinear optical elements replace the beam splitters in a Mach-Zehnder interferometer. A two-mode squeezed state of light is generated inside of such an interferometer. We talk about the phase sensitivities of an SU(1,1) interferometer with different detection schemes and their improvement over the SQL. We also discuss the concept of an optimal detection scheme for phase measurement in an interferometer. We describe a modification of the SU(1,1) interferometer which reduces the experimental complexities while giving the same phase sensitivity. We call the design a truncated SU(1,1) interferometer. We show our experimental results of 4 dB improvement in phase sensitivity over the SQL using a truncated SU(1,1) interferometer. We also compare the theoretical sensitivities of vacuum-seeded configurations of a conventional and a truncated SU(1,1) interferometer, and show our experimental results for the phase sensitivity of the truncated version. We explain the dependence of phase sensitivity on the measurement of squeezing. We talk about the methods to improve the measurement of squeezing in a 4-wave mixing experiment, and our efforts in implementing them. Finally, we mention our progress in measuring a big phase shift using an adaptive algorithm in the truncated SU(1,1) interferometer, and discuss the technicalities involved in big phase measurements.
The SU(1,1) interferometer can be thought of as a Mach-Zehnder interferometer with its linear beam splitters replaced with parametric nonlinear optical processes. We consider the cases of bright- and vacuum-seeded SU(1,1) interferometers using intensity or homodyne detectors. A simplified truncated scheme with only one nonlinear interaction is introduced, which not only beats conventional intensity detection with a bright seed, but can saturate the phase-sensitivity bound set by the quantum Fisher information. We also show that the truncated scheme achieves a sub-shot-noise phase sensitivity in the vacuum-seeded case, despite the phase-sensing optical beams having no well-defined phase.