Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Decoherence in Ramsey Spectroscopy Due to Magnetic Field Gradients

Frank A. Narducci, Arvind Srinivasan, Jon P. Davis, Matthias Zimmermann, Maxim A. Efremov, Ernst Maria Rasel, Wolfgang P. Schleich

Published Jun 8, 2017• 0 citations
OpenAlex

Related papers

Decoherence of Magnetization in a Field Gradient

L. Heller

APS•Apr 1, 2002•0 citations

Minimization of magnetic field-induced shifts in the 171Yb+ ion frequency standard for Ramsey and Hyper-Ramsey spectroscopy

D. S. Krysenko, O. N. Prudnikov, Valery Yudin +2 more

We have researched the possibility of Ramsey and Hyper-Ramsey spectroscopy of 171Yb+ ion octupole transition 2S1/2 (F=0) → 2F7/2 (F=3) in small magnetic fields. A comparative analysis of the shifts of the central resonance in Ramsey and Hyper-Ramsey spectroscopy was carried out. In particular, probe light parameters such as intensity, Rabi frequency and magnetic field values have been determined for achievement the influence of non-linear light shift and second-order Zeeman shift on central resonance shift no more than 10-19.

LaserPhys Youth School-Conference•Jan 1, 2025•0 citations

Microwave field amplitude stabilization using Ramsey spectroscopy signal

Michele Gozzelino, Aldo Godone, Salvatore Micalizio +2 more

We present a method to actively stabilize the amplitude of the microwave field which constitutes the probe for many state-of-the-art compact atomic clocks. The method applies to clocks working in pulsed operation, specifically with a Ramsey scheme. The proposed technique relies on information directly extracted from the clock atomic signal, as it computes the gradient in the two variables (amplitude and frequency) characterizing the probe field, instead of differentiating solely the frequency response, as in usual operation. Magnetic field sensing based on spectroscopy has proven to be a valuable tool for metrology and precise measurement field. We demonstrate the advantage of using the spectroscopic signal to stabilize the microwave field amplitude, in order to reach 10-15stability with compact clocks, by mitigating cavity-pulling shift effects.

European Frequency and Time Forum•Apr 1, 2018•0 citations

Ramsey fringes in optical spectroscopy

Robin M. Hochstrasser

Nature•Jul 1, 1977•3 citations

Magnetic Coherence Resonances and Transitions at Zero Frequency

Edmond Geneux, Georges J. Béné, J. Perrenoud

Advances in electronics and electron physics•Jan 1, 1970•0 citations

Measurement of Magnetic Fields and Field Gradients Using Raman Transitions in Arbitrary Magnetic Fields

S. A. DeSavage, Jon P. Davis, Frank A. Narducci

We have theoretically and experimentally studied Raman resonances in multi-level atoms (specifically 85Rb). By varying the relative orientation of the magnetic field with respect to the propagation direction of the Raman fields, we have changed the spectrum to consist of five, six, or eleven peaks. However, the spectrum was not always an incoherent sum of the five and six peak spectra and was not always symmetric with respect to the magnetically insensitive transition (clock transition). Using Ramsey interference, we explored decoherence and noise sources in or system. We discuss potential application to magnetometry.

Frontiers in Optics•Jan 1, 2012•0 citations
We have researched the possibility of Ramsey and Hyper-Ramsey spectroscopy of 171Yb+ ion octupole transition 2S1/2 (F=0) → 2F7/2 (F=3) in small magnetic fields. A comparative analysis of the shifts of the central resonance in Ramsey and Hyper-Ramsey spectroscopy was carried out. In particular, probe light parameters such as intensity, Rabi frequency and magnetic field values have been determined for achievement the influence of non-linear light shift and second-order Zeeman shift on central resonance shift no more than 10-19.
We present a method to actively stabilize the amplitude of the microwave field which constitutes the probe for many state-of-the-art compact atomic clocks. The method applies to clocks working in pulsed operation, specifically with a Ramsey scheme. The proposed technique relies on information directly extracted from the clock atomic signal, as it computes the gradient in the two variables (amplitude and frequency) characterizing the probe field, instead of differentiating solely the frequency response, as in usual operation. Magnetic field sensing based on spectroscopy has proven to be a valuable tool for metrology and precise measurement field. We demonstrate the advantage of using the spectroscopic signal to stabilize the microwave field amplitude, in order to reach 10-15stability with compact clocks, by mitigating cavity-pulling shift effects.
We have theoretically and experimentally studied Raman resonances in multi-level atoms (specifically 85Rb). By varying the relative orientation of the magnetic field with respect to the propagation direction of the Raman fields, we have changed the spectrum to consist of five, six, or eleven peaks. However, the spectrum was not always an incoherent sum of the five and six peak spectra and was not always symmetric with respect to the magnetically insensitive transition (clock transition). Using Ramsey interference, we explored decoherence and noise sources in or system. We discuss potential application to magnetometry.