Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Korean Physical Society

Theoretically exploring the phase precision in a noisy Mach-Zehnder interferometer

Duan Xie, Chen Haifeng

Published Jun 1, 2017• 1 citation
Publisher

Abstract

This paper presents the phase precision of a Mach-Zehnder interferometer in the presence of two types of quantum noise. Under the influence of amplitude-damping noise, the precisions of three input cases will gradually decrease and be less than the standard quantum limit. When the quantum states are influenced by bit-phase flip, the precisions for inputs of a coherent state and a squeezed vacuum state and the precision of spin squeezing state decrease at first and then increase with increasing η (parameter characterizing the noise strength) from 0 to 1. Comparing the rates at which the precisions decrease, we found that the precision of the spin squeezing state decreased faster than those of the other two cases in most instances.

DOI
10.3938/jkps.70.1016

Related papers

Precision phase measurement in Mach-Zehnder interferometer with three-photon by using a weak coherent and a squeezed vacuum state

Duan, Lifeng

We quantitatively investigate phase measurement in a Mach-Zehnder interferometer (MZI), which is injected with a weak coherent and a squeezed vacuum generated from a spontaneous parametric down-conversion. The measured three-photon coincidence in this system is quantified as a function of a ratio between the amplitude of the coherent state and the squeezed parameter of squeezed vacuum when the photon number is detected at one output of MZI. It shows that the phase sensitivity reaches the Heisenberg limit when an optimal ratio is chosen. This may introduce one approach to quantify phase sensitivity in precision phase measurement.

arXiv:2309.09204•Sep 17, 2023•0 citations

Noise limits on two-photon interferometric sensing

Hamish Scott, Dominic Branford, Niclas Westerberg +2 more

When a photon interferes with itself while traversing a Mach-Zehnder interferometer, the output port where it emerges is influenced by the phase difference between the interferometer arms. This allows for highly precise estimation of the path length difference (delay) but is extremely sensitive to phase noise. By contrast, a delay between the arms of the two-photon Hong-Ou-Mandel interferometer directly affects the relative indistinguishability of the photon pair, affecting the rate of recorded coincidences. This likewise allows for delay estimation, notably less precise but with the advantage of being less sensitive to perturbations of the photons' phase. Focusing on two-photon input states, we here investigate to what degree of noise Mach-Zehnder interferometry retains its edge over Hong-Ou-Mandel interferometry. We also explore the competing benefits of different two-photon inputs for a Mach-Zehnder interferometer and under what parameter regimes each input performs best.

arXiv:2106.13671•Physical Review A•Nov 9, 2021•17 citations

Mach-Zehnder Interferometry at the Heisenberg Limit with Coherent and Squeezed-Vacuum Light

Luca Pezzè, Augusto Smerzi

We show that the phase sensitivity $\ensuremath{\Delta}\ensuremath{\theta}$ of a Mach-Zehnder interferometer illuminated by a coherent state in one input port and a squeezed-vacuum state in the other port is (i) independent of the true value of the phase shift and (ii) can reach the Heisenberg limit $\ensuremath{\Delta}\ensuremath{\theta}\ensuremath{\sim}1/{N}_{T}$, where ${N}_{T}$ is the average number of input particles. We also demonstrate that the Cramer-Rao lower bound of phase sensitivity, $\ensuremath{\Delta}\ensuremath{\theta}\ensuremath{\sim}\phantom{\rule{0ex}{0ex}}1/\sqrt{|\ensuremath{\alpha}{|}^{2}{e}^{2r}+{sinh}^{2}r}$, can be saturated for arbitrary values of the squeezing parameter $r$ and the amplitude of the coherent mode $\ensuremath{\alpha}$ by using a Bayesian phase inference protocol.

arXiv:0705.4631•Physical Review Letters•Feb 19, 2008•370 citations

Phase sensitivity of two nonlinear interferometers with inputting entangled coherent states

Chaoping Wei, Xiao‐Yu Hu, Ya‐Fei Yu +1 more

We investigate the phase sensitivity of the SU(1,1) interfereometer [SU(1,1)I] and the modified Mach–Zehnder interferometer (MMZI) with the entangled coherent states (ECS) as inputs. We consider the ideal case and the situations in which the photon losses are taken into account. We find that, under ideal conditions, the phase sensitivity of both the MMZI and the SU(1,1)I can beat the shot-noise limit (SNL) and approach the Heisenberg limit (HL). In the presence of photon losses, the ECS can beat the coherent and squeezed states as inputs in the SU(1,1)I, and the MMZI is more robust against internal photon losses than the SU(1,1)I.

Chinese Physics B•Apr 1, 2016•17 citations

Enhancement of the phase sensitivity with two-mode squeezed coherent state based on a Mach-Zehnder interferometer

Jun Liu, Tao Shao, Yuanxiang Wang +4 more

We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.

Optics Express•Jul 26, 2023•14 citations

Precision measurement beyond the shot-noise limit

Min Xiao, Ling-An Wu, H. J. Kimble

Improvements in precision beyond the limit set by the vacuum state or zero-point fluctuations of the field are reported for two optical experiments. Both experiments employ the squeezed light from an optical parametric oscillator to reduce the level of fluctuations in one of two quadrature phase amplitudes below the shot-noise level (SNL). The first experiment follows the work of Caves1 on precision interferometry with squeezed states. An increase in signal-to-noise of 2.5 dB relative to the SNL is demonstrated for the detection of phase modulation in a Mach-Zehnder interferometer. In the second experiment amplitude modulation is encoded on a weak signal beam with an acoustooptic modulator. For the case of a squeezed signal beam compared with a beam in a coherent state, an improvement in sensitivity of 2.5 dB is achieved for the detection of amplitude changes of the field. The observed increases in sensitivity in both experiments are currently limited by simple linear losses in propagation and detection and not by the degree of available squeezing.

Annual Meeting Optical Society of America•Jan 1, 1987•3 citations
This paper presents the phase precision of a Mach-Zehnder interferometer in the presence of two types of quantum noise. Under the influence of amplitude-damping noise, the precisions of three input cases will gradually decrease and be less than the standard quantum limit. When the quantum states are influenced by bit-phase flip, the precisions for inputs of a coherent state and a squeezed vacuum state and the precision of spin squeezing state decrease at first and then increase with increasing η (parameter characterizing the noise strength) from 0 to 1. Comparing the rates at which the precisions decrease, we found that the precision of the spin squeezing state decreased faster than those of the other two cases in most instances.
We quantitatively investigate phase measurement in a Mach-Zehnder interferometer (MZI), which is injected with a weak coherent and a squeezed vacuum generated from a spontaneous parametric down-conversion. The measured three-photon coincidence in this system is quantified as a function of a ratio between the amplitude of the coherent state and the squeezed parameter of squeezed vacuum when the photon number is detected at one output of MZI. It shows that the phase sensitivity reaches the Heisenberg limit when an optimal ratio is chosen. This may introduce one approach to quantify phase sensitivity in precision phase measurement.
When a photon interferes with itself while traversing a Mach-Zehnder interferometer, the output port where it emerges is influenced by the phase difference between the interferometer arms. This allows for highly precise estimation of the path length difference (delay) but is extremely sensitive to phase noise. By contrast, a delay between the arms of the two-photon Hong-Ou-Mandel interferometer directly affects the relative indistinguishability of the photon pair, affecting the rate of recorded coincidences. This likewise allows for delay estimation, notably less precise but with the advantage of being less sensitive to perturbations of the photons' phase. Focusing on two-photon input states, we here investigate to what degree of noise Mach-Zehnder interferometry retains its edge over Hong-Ou-Mandel interferometry. We also explore the competing benefits of different two-photon inputs for a Mach-Zehnder interferometer and under what parameter regimes each input performs best.
We show that the phase sensitivity $\ensuremath{\Delta}\ensuremath{\theta}$ of a Mach-Zehnder interferometer illuminated by a coherent state in one input port and a squeezed-vacuum state in the other port is (i) independent of the true value of the phase shift and (ii) can reach the Heisenberg limit $\ensuremath{\Delta}\ensuremath{\theta}\ensuremath{\sim}1/{N}_{T}$, where NT{N}_{T}NT​ is the average number of input particles. We also demonstrate that the Cramer-Rao lower bound of phase sensitivity, $\ensuremath{\Delta}\ensuremath{\theta}\ensuremath{\sim}\phantom{\rule{0ex}{0ex}}1/\sqrt{|\ensuremath{\alpha}{|}^{2}{e}^{2r}+{sinh}^{2}r}$, can be saturated for arbitrary values of the squeezing parameter rrr and the amplitude of the coherent mode $\ensuremath{\alpha}$ by using a Bayesian phase inference protocol.
We investigate the phase sensitivity of the SU(1,1) interfereometer [SU(1,1)I] and the modified Mach–Zehnder interferometer (MMZI) with the entangled coherent states (ECS) as inputs. We consider the ideal case and the situations in which the photon losses are taken into account. We find that, under ideal conditions, the phase sensitivity of both the MMZI and the SU(1,1)I can beat the shot-noise limit (SNL) and approach the Heisenberg limit (HL). In the presence of photon losses, the ECS can beat the coherent and squeezed states as inputs in the SU(1,1)I, and the MMZI is more robust against internal photon losses than the SU(1,1)I.
We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.
Improvements in precision beyond the limit set by the vacuum state or zero-point fluctuations of the field are reported for two optical experiments. Both experiments employ the squeezed light from an optical parametric oscillator to reduce the level of fluctuations in one of two quadrature phase amplitudes below the shot-noise level (SNL). The first experiment follows the work of Caves1 on precision interferometry with squeezed states. An increase in signal-to-noise of 2.5 dB relative to the SNL is demonstrated for the detection of phase modulation in a Mach-Zehnder interferometer. In the second experiment amplitude modulation is encoded on a weak signal beam with an acoustooptic modulator. For the case of a squeezed signal beam compared with a beam in a coherent state, an improvement in sensitivity of 2.5 dB is achieved for the detection of amplitude changes of the field. The observed increases in sensitivity in both experiments are currently limited by simple linear losses in propagation and detection and not by the degree of available squeezing.