Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics

All-optical 4He Magnetometer Driven by Fictitious Oscillating Magnetic Field

Zaisheng Lin, Xiang Peng, Haidong Wang, Liang Shen, He Wang, Hong Mei Guo

Published Jan 1, 2017• 1 citation
Publisher

Abstract

We demonstrate an all-optical 4He magnetometer driven by fictitious oscillating magnetic field achieved by the light shift. The intensity modulated detuning light creates the fictitious oscillating magnetic field to resonate with the Larmor precession.
DOI
10.1364/cleo_at.2017.aw1b.7

Related papers

Laser pumped 4He magnetometer with light shift suppression

Zaisheng Lin, He Wang, Xiang Peng +2 more

We report a laser-pumped 4He atomic magnetometer with light shift suppression through the atomic sensor itself. A linearly polarized light is used to optically align the 4He metastable atoms and we monitor the magneto-optical double resonance (MODR) signals produced by the left- and right-circularly orthogonal components. It is shown that light shift leads to the atomic alignment to orientation conversion effect, and thus, the difference between the two MODR signals. One of these two MODR signals is locked at the Larmor frequency and is used to measure the ambient magnetic field, while the differential signal is, simultaneously, fed back to suppress the light shift. The scheme could be of the advantage to the design of compact magnetometers by reducing the systematic errors due to light shift.

Review of Scientific Instruments•Nov 1, 2016•6 citations

All-Optical Parametric-Resonance Magnetometer Based on 4He Atomic Alignment

Bowen Wang, Xiang Peng, Haidong Wang +2 more

Parametric-resonance magnetometer is a high-sensitivity quantum sensor characterized by applying the non-resonant radio-frequency (RF) fields to the atomic ensemble. The RF fields lead to crosstalk in the multi-sensor design, thus disturbing the magnetic-field measurement results. We propose an optically modulated alignment-based 4He parametric-resonance magnetometer. By using the fictitious field generated by the modulated light shift, parametric resonance is realized, and crosstalk caused by the magnetic RF field is prevented. The relative intensity noise of the lasers is suppressed to optimize the sensitivity of the magnetometer. Our magnetometer experimentally demonstrates a magnetic-field noise floor of 130 fT/Hz1/2 in both open- and closed-loop operations and has the potential to reach 70 fT/Hz1/2 when compared with the optimized magnetic RF scheme. It provides near-zero magnetic-field measurements with a 2 kHz bandwidth at room temperature, which is useful for high-bandwidth measurements in biomagnetic applications.

Sensors•May 31, 2022•4 citations

Nonlinear magneto-optical rotation with modulated light in tilted magnetic fields

Szymon Pustelny, Wojciech Gawlik, Simon Rochester +3 more

Larmor precession of laser-polarized atoms contained in antirelaxation-coated cells, detected via nonlinear magneto-optical rotation (NMOR), is a promising technique for a new generation of ultrasensitive atomic magnetometers. For magnetic fields directed along the light propagation direction, resonances in NMOR appear when linearly polarized light is frequency or amplitude modulated at twice the Larmor frequency. Because the frequency of these resonances depends on the magnitude but not the direction of the field, they are useful for scalar magnetometry. Additional NMOR resonances at the Larmor frequency appear when the magnetic field is tilted away from the light propagation direction in the plane defined by the light propagation and polarization vectors. These resonances, studied both experimentally and with a density matrix calculation in the present work, offer a convenient method of achieving additional information about a direction of the magnetic field.

arXiv:physics/0606257•Physical Review A•Dec 29, 2006•56 citations

Alkali-vapor magnetic resonance driven by fictitious radiofrequency fields

E. Zhivun, Arne Wickenbrock, Brian Patton +1 more

We demonstrate an all-optical 133Cs scalar magnetometer, operating in nonzero magnetic field, in which the magnetic resonance is driven by an effective oscillating magnetic field provided by the AC Stark shift of an intensity-modulated laser beam. We achieve a projected shot-noise-limited sensitivity of 1.7fT/Hz and measure a technical noise floor of 40fT/Hz. These results are essentially identical to a coil-driven scalar magnetometer using the same setup. This all-optical scheme offers advantages over traditional coil-driven magnetometers for use in arrays and in magnetically sensitive fundamental physics experiments, e.g., searches for a permanent electric dipole moment of the neutron.

arXiv:1409.6158•Applied Physics Letters•Nov 10, 2014•33 citations

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

Chris Hovde, Brian Patton, Eric Corsini +2 more

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.

arXiv:1003.1531•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 23, 2010•5 citations

Magneto-optical double resonance driven by fictitious fields

Zaisheng Lin, Xiang Peng, Wenhao Li +2 more

He metastable state with density matrix calculations. Our proposed theoretical explanations based on the fictitious fields show good agreement with experimental results, especially for amplitude and frequency shifts of the signals at Larmor frequency and double Larmor frequency driven by the fictitious electric field.

Optics Express•Mar 24, 2017•7 citations
We report a laser-pumped 4He atomic magnetometer with light shift suppression through the atomic sensor itself. A linearly polarized light is used to optically align the 4He metastable atoms and we monitor the magneto-optical double resonance (MODR) signals produced by the left- and right-circularly orthogonal components. It is shown that light shift leads to the atomic alignment to orientation conversion effect, and thus, the difference between the two MODR signals. One of these two MODR signals is locked at the Larmor frequency and is used to measure the ambient magnetic field, while the differential signal is, simultaneously, fed back to suppress the light shift. The scheme could be of the advantage to the design of compact magnetometers by reducing the systematic errors due to light shift.
Parametric-resonance magnetometer is a high-sensitivity quantum sensor characterized by applying the non-resonant radio-frequency (RF) fields to the atomic ensemble. The RF fields lead to crosstalk in the multi-sensor design, thus disturbing the magnetic-field measurement results. We propose an optically modulated alignment-based 4He parametric-resonance magnetometer. By using the fictitious field generated by the modulated light shift, parametric resonance is realized, and crosstalk caused by the magnetic RF field is prevented. The relative intensity noise of the lasers is suppressed to optimize the sensitivity of the magnetometer. Our magnetometer experimentally demonstrates a magnetic-field noise floor of 130 fT/Hz1/2 in both open- and closed-loop operations and has the potential to reach 70 fT/Hz1/2 when compared with the optimized magnetic RF scheme. It provides near-zero magnetic-field measurements with a 2 kHz bandwidth at room temperature, which is useful for high-bandwidth measurements in biomagnetic applications.
Larmor precession of laser-polarized atoms contained in antirelaxation-coated cells, detected via nonlinear magneto-optical rotation (NMOR), is a promising technique for a new generation of ultrasensitive atomic magnetometers. For magnetic fields directed along the light propagation direction, resonances in NMOR appear when linearly polarized light is frequency or amplitude modulated at twice the Larmor frequency. Because the frequency of these resonances depends on the magnitude but not the direction of the field, they are useful for scalar magnetometry. Additional NMOR resonances at the Larmor frequency appear when the magnetic field is tilted away from the light propagation direction in the plane defined by the light propagation and polarization vectors. These resonances, studied both experimentally and with a density matrix calculation in the present work, offer a convenient method of achieving additional information about a direction of the magnetic field.
We demonstrate an all-optical 133Cs scalar magnetometer, operating in nonzero magnetic field, in which the magnetic resonance is driven by an effective oscillating magnetic field provided by the AC Stark shift of an intensity-modulated laser beam. We achieve a projected shot-noise-limited sensitivity of 1.7fT/Hz and measure a technical noise floor of 40fT/Hz. These results are essentially identical to a coil-driven scalar magnetometer using the same setup. This all-optical scheme offers advantages over traditional coil-driven magnetometers for use in arrays and in magnetically sensitive fundamental physics experiments, e.g., searches for a permanent electric dipole moment of the neutron.
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.